Literature DB >> 28924356

REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS.

Mauro Rodrigues Dos Santos1, Junichiro Sado1, Roberto Medeiros de Sousa1, Osman Rodrigues Roriz1.   

Abstract

OBJECTIVE: To evaluate the intra-observer reproducibility of Schatzker classification for tibial plateau fractures through smartphone applications.
METHODS: Radiographs were evaluated in two incidences (anteroposterior and profile) and CT slices (axial, sagittal and coronal) of 37 patients with tibial plateau fracture. Two evaluators, knee surgery experts, classified the cases by viewing the images of the isolated radiographs and then X-rays associated with CT slices in four different stages via smartphones and then presential assessment. Data were statistically analyzed with the Kappa coefficient (k).
RESULTS: There was intra-observer agreement by comparing the two methods of evaluation: display or via smartphone, and the analysis made showed statistical significance.
CONCLUSION: The use of smartphones did not affect the reliability of Schatzker classification. Level of Evidence III, Diagnostic Study - Investigating a Diagnostic Test.

Entities:  

Keywords:  Cell p. hones/utilization; Mobile applications/utilization; Tibial fractures/classification; Tibial fractures/radiography

Year:  2016        PMID: 28924356      PMCID: PMC5594756          DOI: 10.1590/1413-785220162406159078

Source DB:  PubMed          Journal:  Acta Ortop Bras        ISSN: 1413-7852            Impact factor:   0.513


INTRODUCTION

Tibial plateau fractures are common injuries that include a wide range of morphological patterns. A number of classification systems have been proposed to categorize these types of fractures, in order to simplify communication in clinical practice, to provide guidelines for preoperative planning, and to allow comparison with the data presented in the literature. The three classification systems used in the assessment of tibial plateau fractures include the OTA/AO system, the Schatzker classification and Hohl's classification. - X-rays images and CT scans are commonly and frequently shared through smartphone devices between orthopedic surgeons and fellow residents, a technological facility that allows the debate at any time with team members who are far away from each other. Obviously, it does not replace the presential assessment and care provided to the patient by a qualified professional. Currently, there are numerous software applications that can be installed on smartphones. Health-related applications are increasingly being developed, with approximately 1,000 new applications launched every month and 142 million downloads annually, estimated by 2016. Its use is popular, with 85% of medical professionals using smartphones and 30-50% using applications in clinical practice. The range of applications available for smartphones has been reported in various specialties, including orthopedics, colorectal surgery, anesthesiology, radiology and microbiology. - However, concerns regarding the lack of physician's involvement in developing the application and the reliability of the application's content have been raised. The use of smartphones applications in orthopedics have been described in the literature, such as measuring the angular deviation in hallux valgus , and spinal deformities, measuring the flexion-extension after arthroplasty and also the use of these applications in radiology. , - The aim of this study is to evaluate the intra-observer reliability of the Schatzker classification for tibial plateau fractures using smartphones.

MATERIALS AND METHODS

We retrospectively evaluated 37 cases of tibial plateau fractures treated at the same hospital between 2011 and 2014. All patients had knee radiographs in anteroposterior (AP) and lateral (L) views supplemented with computed tomography (CT). All these tests were stored in digital media. The two evaluators were orthopedic surgeons, members of the Brazilian Society of Orthopedics and Traumatology (SBOT) and the Brazilian Society of Knee Surgery (SBCJ) with expertise in the treatment of tibial plateau fractures. They will be hereafter designated as evaluator 1 and evaluator 2. In the first stage, all AP and L radiographs were photographed using a smartphone and sent, case by case, in random and independent order to smartphones of the two evaluators using the mobile application Whatsapp(r). Then, they applied the Schatzker classification and sent the evaluations to the examiner, which, in turn, sent the photos of other cases to the evaluators, successively, until completion of the 37 cases. The second stage was carried out similarly to the first, in random and independent order, however, in addition to the X-rays, CT images in coronal, axial and sagittal views were added to each evaluated case. In the third and fourth steps, performed six months after the first, the same cases and images were rated by two evaluators in presential way, directly from the hospital's computer monitor. In the third stage, the examiner presented only the X-ray image, and in the fourth stage, X-rays and CT scans. The smartphones used for both capturing and sending images and classifying images by the evaluators were Apple(r) iPhone 5S model with 4-inch screen. Regarding the presential assessment, the images were displayed on a full HD 21.5-inch monitor (1920 x 1080 pixels), and the software DViewer was used to visualize the images. Both the computer as the smartphone software allowed magnification of the image on their screens. Data were entered and manipulated in Excel charts, for further processing using the Statistical Package for Social Sciences (SPSS) for Windows (version 21.0). For concordance analysis was used the Kappa test. The values ​​of this index ranged from +1 (perfect agreement) through zero (fortuitous or chance agreement) up to -1 (no agreement). In general, values ​​lower than 0.5 were considered unsatisfactory, values between 0.5 and 0.75 were satisfactory, and values higher than 0.75 are considered excelent.13 For all tests we used a 95% level of confidence, i.e., p<0.05 was considered statistically significant. This study, that dealt with analysis of medical records, did not require approval by the Ethics Committee.

RESULTS

Both evaluators showed significant agreement, with Kappa above 0.7 and p <0.001, in X-ray only presential and smartphone intra-observer evaluations. (Table 1)
Table 1

Concordance analysis of the results of X-ray observations in presential way and using smartphones.

ObserverConcordance Discordance Kappa p
N%n%
Evaluator 13081.1718.90.77< 0.001
Evaluator 22978.4821.60.73< 0.001
Regarding presential and smartphone evaluation of X-ray image and CT scan, we observed that despite the evaluator 1 showed Kappa 0.68 and the evaluator 2 Kappa 0.81, both had very good and significant agreement with Kappa above 0.6 and p<0.001. (Table 2)
Table 2

Concordance analysis of the results of X-ray plus CT-scan observations in presential way and using smartphones.

ObserverConcordance Discordance Kappa p
N%n%
Evaluator 12875.7924.30.68< 0.001
Evaluator 23286.5513.50.81< 0.001
The analysis of observations together by both evaluators, both presential as smartphone evaluations of x-ray alone or together with CT scan showed significant agreement, with Kappa above 0.7 and p<0.001. (Table 3)
Table 3

Concordance analysis of the results of observations by evaluator 1 + evaluator 2 in presential way and using smartphones.

MethodConcordance Discordance Kappa p
N%n%
RX5979.71520.30.75< 0.001
RX + TC6081.11418.90.75< 0.001

DISCUSSION

A common and frequent practice among orthopedic surgeons and residents is to share radiological images and tomography scans by electronic means. However, this practice requires scientific validation, since it is not known whether this technology may lead to mistaken interpretation of the images, and, consequently, improper decision making by the surgical team. In this study, the application of Schatzker classification for tibial plateau fractures through images interpreted on smartphones screens versus presential screening in intra-observer analysis was considered satisfactory or excellent, with all indices above 0.5, the largest 0.81 and the lowest 0.68. It should be noticed that the two evaluators are orthopedic surgeons experienced in the treatment of tibial plateau fractures, which enhanced the degree of agreement. In a study by Albuquerque et al., it has been shown that inexperienced surgeons tend to have lower intra- and inter-observer variability for the different classifications of tibial plateau fractures (Hohl, AO or Schatzker). Therefore, we chose to employ experienced surgeons in this work, minimizing the effects of this important variable, enabling us to focus specifically on possible influences of smartphone devices on the results. Other studies have observed unsatisfactory K indices (near 0.38) in inter-observer analysis , and satisfactory kappa values (0.68) in intra-observer analysis for this classification, which makes clear that the correlation value decreases when the evaluation is between the evaluators. In this study, the concordance results are similar to results obtained in intra-observer analysis for Schatzker classification.

CONCLUSION

The use of images through smartphone devices did not interfere with the intra-observer agreement of Schatzker classification of tibial plateau fractures in this study. The same result was obtained to rank X-rays only and also X-rays combined with tomography scans.
  14 in total

1.  AO or Schatzker? How reliable is classification of tibial plateau fractures?

Authors:  N P Walton; S Harish; C Roberts; C Blundell
Journal:  Arch Orthop Trauma Surg       Date:  2003-08-12       Impact factor: 3.067

2.  Flexible image evaluation: iPad versus secondary-class monitors for review of MR spinal emergency cases, a comparative study.

Authors:  Jonathan P McNulty; John T Ryan; Michael G Evanoff; Louise A Rainford
Journal:  Acad Radiol       Date:  2012-04-14       Impact factor: 3.173

3.  Use of the iPhone for radiographic evaluation of hallux valgus.

Authors:  Tolga Ege; Ozkan Kose; Kenan Koca; Bahtiyar Demiralp; Mustafa Basbozkurt
Journal:  Skeletal Radiol       Date:  2012-06-06       Impact factor: 2.199

4.  The iPad tablet computer for mobile on-call radiology diagnosis? Auditing discrepancy in CT and MRI reporting.

Authors:  Sindhu John; Angeline C C Poh; Tchoyoson C C Lim; Elizabeth H Y Chan; Le Roy Chong
Journal:  J Digit Imaging       Date:  2012-10       Impact factor: 4.056

5.  The classification systems for tibial plateau fractures: how reliable are they?

Authors:  Subramanyam Naidu Maripuri; Prabhakar Rao; Abraham Manoj-Thomas; Khitish Mohanty
Journal:  Injury       Date:  2008-10       Impact factor: 2.586

6.  Classification systems for tibial plateau fractures; does computed tomography scanning improve their reliability?

Authors:  Alexander Brunner; Monika Horisberger; Benjamin Ulmar; Alexander Hoffmann; Reto Babst
Journal:  Injury       Date:  2009-09-09       Impact factor: 2.586

7.  Smartphone apps for orthopaedic surgeons.

Authors:  Orrin I Franko
Journal:  Clin Orthop Relat Res       Date:  2011-05-06       Impact factor: 4.176

8.  Inter- and intra-observer reliability of a smartphone application for measuring hallux valgus angles.

Authors:  Richard Walter; Jonathan D Kosy; Richard Cove
Journal:  Foot Ankle Surg       Date:  2012-09-28       Impact factor: 2.705

Review 9.  Smartphones, tablets and mobile applications for radiology.

Authors:  András Székely; Roland Talanow; Péter Bágyi
Journal:  Eur J Radiol       Date:  2013-01-09       Impact factor: 3.528

10.  Importance of radiological studies by means of computed tomography for managing fractures of the tibial plateau.

Authors:  Clécio de Lima Lopes; Carlos Antônio da Rocha Cândido Filho; Thiago Almeida de Lima E Silva; Marcelo Carvalho Krause Gonçalves; Ricardo Lyra de Oliveira; Paulo Rogério Gomes de Lima
Journal:  Rev Bras Ortop       Date:  2014-10-30
View more
  1 in total

1.  Reliability of teleconsultation in the diagnosis and treatment of proximal humeral fractures.

Authors:  Çağdaş Pamuk
Journal:  Emerg Radiol       Date:  2022-06-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.