Literature DB >> 28911669

Simultaneous determination of ascorbic acid and caffeine in commercial soft drinks using reversed-phase ultraperformance liquid chromatography.

Fatma Turak1, Remziye Güzel2, Erdal Dinç3.   

Abstract

A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H3PO4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  ascorbic acid; caffeine; commercial soft drinks; quantification; reverse-phase ultraperformance liquid chromatography

Mesh:

Substances:

Year:  2016        PMID: 28911669      PMCID: PMC9332539          DOI: 10.1016/j.jfda.2016.09.004

Source DB:  PubMed          Journal:  J Food Drug Anal            Impact factor:   6.157


1. Introduction

Caffeine (CAF; 1,3,7-trimethylxanthine), which is a xanthine alkaloid, has widely been used in tea (black, white, and green), coffee, guarana, chocolate, cocoa, soft and energy drinks, and pharmaceutical products. In recent years, the use of CAF in energy drinks has increased significantly due to its excitation and analgesic properties. However, the use of a high dosage of CAF gives rise to some symptoms such as headache, slowness, fatigue, and depression. Ascorbic acid {AA; (5R)-[(1S)-1,2-dihydroxyethyl]-3,4-dihydroxyfuran-2(5H)-one} is one of the most important vitamins, which plays an important role for hydroxylation reactions and antioxidants. Symptoms of lack of AA are physical and mental infirmity, fatigue, weight loss, bruising, dry hair and skin, and increased sensibility of infections. Nowadays, the production of commercial drinks as a function of the developments in the food industry has increased tremendously. Taking such situations into account, quality control and routine analysis of commercial drinks have very vital importance for the human health and life quality. In this context, quantitative analysis and quality control of commercial drinks require new powerful analytical methods giving reliable, precise, and accurate results with short runtime and low cost of analysis. Several analytical methods including spectrophotometry for CAF [1,2] and AA [3], high-performance liquid chromatography for CAF [4-16] and AA [17-22], liquid chromatography–mass spectrometry for CAF [23] and AA [24], voltammetry for CAF [25-27] and AA [28-32], Fourier transform infrared spectrophotometry for CAF [33-35] and AA [36], chemiluminescence for CAF [37], gas chromatography–mass spectrometry for CAF [38], ion chromatography for CAF [39], capillary electrophoresis for CAF [40], and ultra-high-performance liquid chromatography for CAF [41] and AA [42] have been reported for the analysis of the related compounds in drinks and pharmaceuticals. A literature survey revealed that there was no report about the simultaneous estimation of AA and CAF in the mentioned samples. Hence, the authors have attempted to develop a rapid, precise, and accurate method for the simultaneous determination of these active compounds in commercial drink samples. Some typical studies related to AA [43,44] and CAF [45] were reported. Today, the ultraperformance liquid chromatography (UPLC) method is preferable to high-performance liquid chromatography for the analysis of raw samples, food products, drug preparations, and compounds in biological fluids due to short runtime and less solvent consumption. Moreover, the UPLC technique offers new possibilities in liquid chromatography, giving short analysis time and better chromatographic elution for the simultaneous determination of compounds in samples with adequate precision and accuracy. In this study, a new reversed-phase UPLC (RP-UPLC) method was developed for the simultaneous quantitative analysis of AA and CAF in 11 different commercial drinks. The validation of the proposed UPLC method was carried out analyzing standard addition samples to evaluate its precision, accuracy, and selectivity. It was concluded that the UPLC method provided successful results for the quantitative estimation and quality control of the analyzed commercial drink samples containing CAF and AA. The analysis results provided by the developed and validated RP-UPLC method were compared with those obtained by the literature methods.

2. Experimental

2.1. Instrument and software

Chromatographic separation was carried out using the Waters ACQUITY UPLC H-Class system, including a quaternary solvent manager photodiode array detector, a cooling autosampler, and an oven enabling the control of column temperature. Chromatographic data collection and evaluation were made by Waters Empower2 chromatography software. Chromatographic elution of AA and CAF was performed via a Waters BEH C18 column (100 mm × 2.1 mm, 1.7 μm i.d.).

2.2. Chromatographic conditions

In the chromatographic analysis, the analytical column was the Waters BEH C18 column (100 mm × 2.1 mm, 1.7 μm i.d.). The mobile phase for the elution of AA and CAF in samples in the presence of an internal standard (IS) was a mixture of acetonitrile and 0.2M H3PO4 (11:89 v/v). The mobile phase was filtered through a 0.20 μm microfilter. The total runtime of AA and CAF with IS was 14 minutes, with a flow rate of 0.25 mL/min and column temperature of 50°C. AA and CAF were detected at 244.0 nm and 273.6 nm, respectively.

2.3. Reagents

Acetonitrile was of high-performance liquid chromatography grade (Sigma-Aldrich, Germany), and H3PO4 (Merck, Germany), CAF (Sigma-Aldrich, USA), and AA (Merck, Germany) were of guaranteed reagent grade. Water purified with Milli-Q Gradient A10 Milipore System (Merck Milipore, ABD, USA) was used during chromatographic analysis. All solutions were filtered through a 0.20 μm hydrophilic PTFE syringe filter (Minisart, Germany).

2.4. Commercial drink products

A commercial energy drink (Burn energy drink) and 10 commercial ice tea drinks, consisting of Didi bargamot tea, Didi lemon tea, Fuse melon tea, Fuse lemon tea, Fuse pine-mango tea, Fuse peach tea, Lipton apple tea, Lipton green tea, Lipton lemon tea, and Lipton peach tea, were analyzed by the proposed RP-UPLC method. All the commercial drink products were purchased from local supermarkets.

2.5. Standard solutions

Standard stock solutions of AA, CAF, and caffeic acid were separately prepared by dissolving 10 mg of each compound in 100 mL of 0.1M HCl. A standard calibration set of five mixtures containing 2.5–40 μg/mL of AA and 4.0–44.0 μg/mL of CAF in the presence of 12 μg/mL of caffeic acid as an IS was freshly prepared from the above stock solutions of the analyzed compounds. For method validation in the working concentration range of AA and CAF, standard addition samples were prepared by adding the mentioned standard stock solutions (at 3 different levels: low—2.5 μg/mL, medium—10 μg/mL, and high—30 μg/mL of AA, and low—4.0 μg/mL, medium—14 μg/mL, and high—34 μg/mL of CAF in the presence of 12 μg/mL IS in 3 replicates) to the solutions of each commercial drink. Under the optimized conditions, chromatograms of the calibration solutions, standard addition samples, and commercial drinks were recorded for the estimation of the amounts of AA and CAF in their related samples.

2.6. Preparation of commercial samples

For the analysis of the commercial drinks, sample solutions were degassed thoroughly in an ultrasonic bath for 25 minutes. An appropriate volume of samples was transferred to a 10 mL volumetric flask, and the flask was filled up with mobile phase to the mark and sonicated for 10 minutes. Prior to the UPLC analysis, the samples were filtered through a 0.2 μm membrane filter. This procedure was repeated nine times for each commercial sample. The resulting samples as three replicates were injected into the UPLC system for recording the chromatograms of AA and CAF samples.

3. Results and discussion

3.1. Method development and application

Several mobile phases in different compositions concerning organic solvents such as methanol and acetonitrile and different buffers such as acetate and phosphate with various pH levels were tested for finding the optimal conditions to get desirable elution of AA and CAF in the presence of IS. Based on the use of the Waters BEH C18 column (100 mm × 2.1 mm, 1.7 μm i.d.), a mobile phase consisting of acetonitrile and 0.2M H3PO4 (11:89, v/v), with a flow rate of 0.25 μL/min and column temperature of 50°C, was found to be very suitable for adequate elution of AA and CAF in samples with IS. Sample injection volume was 1.0 μL during chromatographic analysis. As can be seen in Figure 1, the optimal chromatographic detection wavelengths for AA and CAF were chosen as 244.0 nm and 273.6 nm, respectively.
Figure 1

UV spectra showing the detection wavelengths of the AA and CAF compounds. AA = ascorbic acid; CAF = caffeine.

The calibration samples of AA and CAF in the concentration ranges of 2.5–40 μg/mL and 4.0–44.0 μg/mL containing 12 μg/mL IS were prepared by starting from the stock solutions of the analyzed compounds. The chromatograms of calibration samples for AA and CAF were recorded under optimized chromatographic conditions, as indicated in Figures 2A and 3A, respectively.
Figure 2

Chromatograms of AA in (A) calibration set and (B) commercial drinks obtained by detection at 244 nm. In the chromatograms of Figures 2A and 2B, the letters a, b, and c correspond to AA, CAF, and IS, respectively. AA = ascorbic acid; BED = Burn energy drink; CAF = caffeine; DBT = Didi bargamot tea; DLT = Didi lemon tea; FMT = Fuse melon tea; FLT = Fuse lemon tea; FPMT = Fuse pine-mango tea; FPT = Fuse peach tea; IS = internal standard; LAT = Lipton apple tea; LGT = Lipton green tea; LLT = Lipton lemon tea; LPT = Lipton peach tea.

Figure 3

Chromatograms of CAF in (A) calibration set and (B) commercial drinks obtained by detection at 273.6 nm. In the chromatograms of Figures 3A and 3B, the letters a, b, and c correspond to AA, CAF, and IS, respectively. AA = ascorbic acid; BED = Burn energy drink; CAF = caffeine; DBT = Didi bargamot tea; DLT = Didi lemon tea; FMT = Fuse melon tea; FLT = Fuse lemon tea; FPMT = Fuse pine-mango tea; FPT = Fuse peach tea; IS = internal standard; LAT = Lipton apple tea; LGT = Lipton green tea; LLT = Lipton lemon tea; LPT = Lipton peach tea.

A similar chromatographic recording procedure was applied to standard addition samples and commercial samples. As can be seen in Figures 2A and 3A, the elution times of AA and CAF with IS were observed to be 2.5 minutes, 3.0 minutes, and 3.5 minutes, respectively. Calibration graphs for AA and CAF in the linear working concentration ranges of the related compounds were computed from the mathematical relationship between concentration and peak-area ratio of AA/IS and CAF/IS at 244.0 nm and 273.6 nm, respectively. The regression analysis and statistical results were given in Table 1. The concentrations of AA and CAF in the analyzed commercial drinks were determined using the calculated calibration graphs.
Table 1

Least squares regression analysis and statistical results.

ParametersAACAF
λ (nm)244.0273.6
m 0.23540.1512
n 0.05390.0095
r 1.00000.9999
SE(m)0.00090.0012
SE(n)0.01850.0323
SE(r)0.02740.0367
LOD (μg/mL)0.531.44
LOQ (μg/mL)1.764.78

AA = ascorbic acid; CAF = caffeine; LOD = limit of detection (μg/mL); LOQ = limit of quantitation (μg/mL); m = slope of regression equation; n = intercept of regression equation; r = regression co-efficient; SE(m) = standard error of slope; SE(n) = standard error of intercept; SE(r) = standard error of regression coefficient.

3.2. Method validity and applicability

The validity of the developed UPLC method was assessed by estimating its precision, accuracy, linearity, selectivity, limit of detection, and limit of quantitation. Good linearity for AA and CAF was reported from their calibration curves, giving excellent correlation coefficients as shown in Table 1. The limit of detection, which corresponds to a signal/noise ratio of 3, and the limit of quantitation, which corresponds to a signal/noise ratio of 10, were computed from the slope and intercept’s standard deviation of linear regression equation for each compound. Both the limit of detection and the limit of quantitation for the analyzed compounds are listed in Table 1. Accuracy and precision were evaluated by analyzing the standard addition samples using the proposed UPLC method. The standard addition samples were prepared by adding known amounts of AA and CAF (at 3 different concentration levels: 2.5 μg/mL, 10.0 μg/mL, and 30.0 μg/mL of AA and 4.0 μg/mL, 14.0 μg/mL, and 34.0 μg/mL of CAF) to the analyzed commercial drink samples, as indicated in Table 2. As can be seen in this table, percent recovery results, standard deviations, and relative standard deviations were calculated from the added and found amounts of AA and CAF in the standard addition samples. The results obtained for the validity and applicability of the developed UPLC method to analyze the related compounds were found to be within the acceptable limits.
Table 2

Analysis results obtained from the standard addition samples by the developed RP-UPLC method.

Added (μg/mL)AA, found (μg/mL)

BEDDBTDLTFMTFLTFPMTFPTLATLGTLLTLPT
2.52.462.442.562.542.442.402.612.572.552.472.39
1010.0610.099.9210.4410.0910.139.859.909.8710.0510.16
3029.9829.9830.0230.0229.9829.9630.0430.0330.0429.9929.96
AA, recovery (%)
98.397.4102.3101.697.496.1104.3102.9102.198.795.4
100.6100.999.2104.4100.9101.398.599.098.7100.5101.6
99.999.9100.1100.199.999.9100.1100.1100.110099.9
Mean99.699.4100.5102.099.499.1101.0100.7100.399.799.0
SD1.211.781.612.221.772.672.982.001.730.923.17
RSD1.221.791.602.181.782.692.951.991.730.923.20

Added (μg/mL)CAF, found (μg/mL)

BEDDBTDLTFMTFLTFPMTFPTLATLGTLLTLPT

43.923.893.924.174.084.203.524.063.884.064.14
1414.1314.1714.1213.7413.8913.6914.7113.9114.1913.9013.79
3433.9633.9433.9634.0934.0434.1033.7634.0333.9434.0334.07
CAF, recovery (%)
97.997.298.0104.3101.9105.188.1101.696.9101.6103.5
100.9101.2100.998.299.297.8105.199.3101.399.398.5
99.999.899.9100.3100.1100.399.3100.199.8100.1100.2
Mean99.699.499.6100.9100.4101.197.5100.399.4100.3100.7
SD1.542.011.443.121.383.708.641.152.241.172.56
RSD1.552.021.453.091.373.668.871.142.261.172.54

AA = ascorbic acid; CAF = caffeine; RP-UPLC = reversed-phase ultraperformance liquid chromatography; RSD = relative standard deviation; SD = standard deviation.

Selectivity of the proposed UPLC method was evaluated by comparing the slopes of the regression equations of the analyzed compounds and their standard addition samples containing commercial drinks. The comparison of the slopes of the regression lines of calibration and standard addition samples was carried out using the t test with 95% confidence interval. The statistical results of the t test with p values for AA and CAF are given in Table 3. From the t test results given in Table 3, no significant difference was observed between the values of slopes of regression equations of the calibration and standard addition samples. This indicates that there is no matrix effect on the analysis of the marketed drinks using the proposed UPLC method.
Table 3

Statistical comparison results of the regression slopes of the calibration and standard addition samples using t test.

SamplesAACAF


λ (nm)Regression equationt test p λ (nm)Regression equationt test p
a 244.0Y = 0.2354C + 0.0540273.6Y = 0.1512C + 0.0095
BED244.0Y = 0.2385C + 0.18022.470.07273.6Y = 0.1501C + 1.07130.670.54
DBT244.0Y = 0.2313C + 0.86602.590.06273.6Y = 0.1508C + 0.35320.320.77
DLT244.0Y = 0.2324C + 0.72502.040.11273.6Y = 0.1532C + 0.28301.270.27
FMT244.0Y = 0.2366C + 1.62701.030.99273.6Y = 0.1531C + 0.23590.760.49
FLT244.0Y = 0.2332C + 1.78251.390.24273.6Y = 0.1497C + 0.41390.980.38
FPMT244.0Y = 0.2376C + 0.57531.020.37273.6Y = 0.1477C + 0.50831.240.28
FPT244.0Y = 0.2384C − 0.04311.270.27273.6Y = 0.1450C + 0.38381.020.36
LAT244.0Y = 0.2365C + 0.43880.660.54273.6Y = 0.1490C + 0.48861.540.20
LGT244.0Y = 0.2385C + 1.57021.470.14273.6Y = 0.1508C + 0.46980.210.84
LLT244.0Y = 0.2363C + 1.44420.840.24273.6Y = 0.1494C + 0.41261.250.28
LPT244.0Y = 0.2419C + 2.07382.560.06273.6Y = 0.1494C + 0.40201.550.20

t table = 2.78 and p = 0.05.

AA = ascorbic acid; BED = Burn energy drink; CAF = caffeine; DBT = Didi bargamot tea; DLT = Didi lemon tea; FMT = Fuse melon tea; FLT = Fuse lemon tea; FPMT = Fuse pine-mango tea; FPT = Fuse peach tea; LAT = Lipton apple tea; LGT = Lipton green tea; LLT = Lipton lemon tea; LPT = Lipton peach tea.

Calibration equations of AA and CAF are given in Table 1.

3.3. Analysis of commercial drinks

Samples of commercial drinks were prepared for chromatographic analysis as described in the 2.6. section, preparation of commercial samples. Under optimized chromatographic conditions, chromatograms of the commercial drink samples for the analysis of AA and CAF were recorded, as indicated in Figures 2B and 3B, respectively. By replacing the peak area ratio of AA/IS and CAF/IS in the calibration equation of each compound, the amounts of AA and CAF in 11 different commercial samples were computed. Their analysis results are given in Table 4. As it can be seen in Table 4, a good accordance with the acceptable standard deviation and relative standard deviation was reported for the analysis results obtained by applying the developed RP-UPLC to the commercial drinks.
Table 4

Determination results of AA and CAF in the commercial drinks analyzed by the developed RP-UPLC method.

Sample no.AA (mg/L)

BEDDBTDLTFMTFLTFPMTFPTLATLGTLLTLPT
115.6772.3962.69144.59152.3322.912.4038.40133.64125.67177.11
215.6572.2362.42145.37153.1722.912.5038.04133.00125.82177.01
315.5272.2762.10150.27155.3124.952.5538.17132.50124.78175.43
415.1571.7959.53140.72151.3223.622.4239.98133.24121.27167.28
515.1071.2060.01140.38152.2123.622.4439.81132.49120.64167.87
614.9971.7959.70140.39152.1523.822.4039.81132.62120.21166.49
714.4372.3962.81142.17153.7323.032.4137.44126.74118.57168.39
814.4871.8263.01142.55153.4523.032.4037.36125.72118.99168.05
914.3971.8662.76141.67154.0822.992.4137.30125.33118.65167.49
Mean15.0471.9761.67143.12153.0823.432.4438.48130.59121.62170.57
SD0.520.391.473.211.220.670.051.113.533.004.52
RSD3.430.542.382.240.792.862.172.882.702.472.65

Sample no.CAF (mg/L)

BEDDBTDLTFMTFLTFPMTFPTLATLGTLLTLPT

1139.9845.6138.1231.1052.9334.3131.7664.7558.2853.6952.98
2140.6045.7338.3130.8653.1734.4531.9264.6058.5654.0752.85
3140.1045.8838.2431.2653.4034.2331.8864.8758.5854.0153.19
4146.8847.6540.1632.0654.9636.1233.9163.5561.8057.0255.00
5146.9147.5339.9532.3055.1135.8333.9862.9961.7657.5854.91
6146.4421.6639.9432.3254.9735.8333.9862.6862.4157.4055.57
7149.1748.9440.4932.2156.7435.7834.5763.3563.4657.8955.57
8149.2348.7040.4532.3556.5836.0034.2963.4363.5557.8955.69
9149.4048.7340.4332.5056.3735.9734.6462.9363.1257.9655.55
Mean145.4144.4939.5731.8854.9235.3933.4463.6861.2856.3954.59
SD4.048.661.030.631.480.811.220.842.201.881.22
RSD2.7819.472.601.972.702.283.641.323.593.332.24

AA = ascorbic acid; BED = Burn energy drink; CAF = caffeine; DBT = Didi bargamot tea; DLT = Didi lemon tea; FMT = Fuse melon tea; FLT = Fuse lemon tea; FPMT = Fuse pine-mango tea; FPT = Fuse peach tea; LAT = Lipton apple tea; LGT = Lipton green tea; LLT = Lipton lemon tea; LPT = Lipton peach tea; RP-UPLC = reversed-phase ultraperformance liquid chromatography; RSD = relative standard deviation; SD = standard deviation.

4. Conclusions

A new RP-UPLC method was developed and validated for the quantitative estimation of AA and CAF in 11 different commercial drinks without requiring additional chemical pre-treatment. This study indicates that the proposed RP-UPLC approach gives us reliable, precise, and accurate results for the simultaneous quantification of the analyzed AA and CAF in commercial soft drinks with adequate runtime and low solvent consumption. In this study, the newly developed RP-UPLC method allowed for the simultaneous quantitation of AA and CAF in analyzed samples, whereas literature UPLC methods with electrospray ionization–multiple tandem mass spectrometry detection for the analysis of CAF alone [41] and photodiode array detection for the analysis of AA alone [42] require the use of pretreatment for sample preparation. In our case, after diluting commercial samples with the solvent system, filtered samples were directly injected into the UPLC system without using an initial extraction procedure. The mentioned arguments indicated that the newly developed RP-UPLC approach has advantages (simultaneous quantification of the related active compounds in samples without using preliminary extraction or chemical procedure) over literature UPLC methods. As a consequence, the developed and validated RP-UPLC method is a very useful technique for the quality control and routine analysis of marketed drinks containing AA and CAF substances.
  22 in total

1.  Liquid chromatographic method for the simultaneous determination of caffeine and fourteen caffeine metabolites in urine.

Authors:  E K Bendriss; N Markoglou; I W Wainer
Journal:  J Chromatogr B Biomed Sci Appl       Date:  2000-09-15

2.  Rapid determination of caffeine in tea leaves.

Authors:  Hideki Horie; Atsushi Nesumi; Tomomi Ujihara; Katsunori Kohata
Journal:  J Chromatogr A       Date:  2002-01-04       Impact factor: 4.759

Review 3.  Rapid determination of vitamin C by NIR, MIR and FT-Raman techniques.

Authors:  Hong Yang; Joseph Irudayaraj
Journal:  J Pharm Pharmacol       Date:  2002-09       Impact factor: 3.765

4.  Rapid determination of caffeine in one drop of beverages and foods using drop-to-drop solvent microextraction with gas chromatography/mass spectrometry.

Authors:  Kamlesh Shrivas; Hui-Fen Wu
Journal:  J Chromatogr A       Date:  2007-09-14       Impact factor: 4.759

5.  Spectrophotometric determination of caffeine and theophylline in pure alkaloids and its application in pharmaceutical formulations.

Authors:  D K Singh; Archana Sahu
Journal:  Anal Biochem       Date:  2005-03-23       Impact factor: 3.365

6.  Simple high-performance liquid chromatography method for the simultaneous determination of serum caffeine and paraxanthine following rapid sample preparation.

Authors:  D T Holland; K A Godfredsen; T Page; J D Connor
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1998-04-10

7.  Determination of caffeine and its metabolites by micellar electrokinetic capillary electrophoresis.

Authors:  Y Zhao; C E Lunte
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1997-01-24

8.  Simultaneous high-performance liquid chromatographic determination of caffeine and theophylline for routine drug monitoring in human plasma.

Authors:  E Schreiber-Deturmeny; B Bruguerolle
Journal:  J Chromatogr B Biomed Appl       Date:  1996-03-03

9.  Trace determination of caffeine in surface water samples by liquid chromatography--atmospheric pressure chemical ionization--mass spectrometry (LC-APCI-MS).

Authors:  Piero R Gardinali; Xu Zhao
Journal:  Environ Int       Date:  2002-12       Impact factor: 9.621

Review 10.  Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

Authors:  A B Shehata; M S Rizk; E A Rend
Journal:  J Food Drug Anal       Date:  2016-07-30       Impact factor: 6.157

View more
  6 in total

1.  Ascorbic acid detector based on fluorescent molybdenum disulfide quantum dots.

Authors:  Yaping Zhong; Yibiao Zou; Xianhong Yang; Zhentan Lu; Dong Wang
Journal:  Mikrochim Acta       Date:  2021-12-07       Impact factor: 5.833

2.  Sulfur quantum dot-based "ON-OFF-ON" fluorescence platform for detection and bioimaging of Cr(vi) and ascorbic acid in complex environmental matrices and biological tissues.

Authors:  Mengke Xia; He Mei; Qiuhui Qian; Randy A Dahlgren; Ming Gao; Xuedong Wang
Journal:  RSC Adv       Date:  2021-03-11       Impact factor: 3.361

3.  The fabrication of an Ni6MnO8 nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection.

Authors:  Hongliang Jia; Jianwei Zhao; Lirong Qin; Min Zhao; Gang Liu
Journal:  RSC Adv       Date:  2019-08-28       Impact factor: 4.036

4.  Development, Validation, and Use of 1H-NMR Spectroscopy for Evaluating the Quality of Acerola-Based Food Supplements and Quantifying Ascorbic Acid.

Authors:  Asma Bourafai-Aziez; Daniel Jacob; Gwladys Charpentier; Emmanuel Cassin; Guillaume Rousselot; Annick Moing; Catherine Deborde
Journal:  Molecules       Date:  2022-08-31       Impact factor: 4.927

5.  Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages.

Authors:  Luca Redivo; Miroslav Stredanský; Elisabetta De Angelis; Luciano Navarini; Marina Resmini; Ĺubomír Švorc
Journal:  R Soc Open Sci       Date:  2018-05-02       Impact factor: 2.963

6.  Ultra-sensitive electrochemical sensing of acetaminophen and codeine in biological fluids using CuO/CuFe2O4 nanoparticles as a novel electrocatalyst.

Authors:  Foroozan Hasanpour; Masoumeh Taei; Somayeh Tahmasebi
Journal:  J Food Drug Anal       Date:  2017-11-10       Impact factor: 6.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.