| Literature DB >> 28903234 |
Vojtech Adam1, Radka Mikelova2, Jaromír Hubalek3, Pavel Hanustiak4, Miroslava Beklova4, Petr Hodek5, Ales Horna6, Libuse Trnkova3, Marie Stiborova5, Ladislav Zeman7, Rene Kizek8.
Abstract
About biological affecting of flavonoids on animal organisms is known less,thus we selected flavonoids, flavanones and flavones, and their glycosides, which wereexamined as potential inducers of cytochrome(s) P450 when administrated by gavages intoexperimental male rats. The study was focused on induction of CYP1A1, the majorcytochrome P450 involved in carcinogen activation. The data obtained demonstrate thenecessity of taking into account not only ability of flavonoids to bind to Ah receptor(induction factor) but also to concentrate on their distribution and metabolism (includingcolon microflora) in the body. After that we examined certain flavonoids as potential inducers of cytochrome P450, we wanted to suggest and optimize suitable electrochemical technique for determination of selected flavonoids (quercetin, quercitrin, rutin, chrysin and diosmin) in body liquids. For these purposes, we selected square wave voltannetry using carbon paste electrode. Primarily we aimed on investigation of their basic electrochemical behaviour. After that we have optimized frequency, step potential and supporting electrolyte. Based on the results obtained, we selected the most suitable conditions for determination of the flavonoids as follows: frequency 180 Hz, step potential 1.95 mV/s and phosphate buffer of pH 7 as supporting electrolyte. Detection limits (3 S/N) of the flavonoids were from units to tens of nM except diosmin, where the limit were higher than μM. In addition, we attempted to suggest a sensor for analysis of flavonoids in urine. It clearly follows from the results obtained that flavonoids can be analysed in the presence of animal urine, because urine did not influence much the signals of flavonoids (recoveries of the signals were about 90 %).Entities:
Keywords: antioxidant; cancer; carbon paste electrode; cytochrome P450; flavonoids; square wave voltammetry; western blot analysis
Year: 2007 PMID: 28903234 PMCID: PMC3864529 DOI: 10.3390/s7102402
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.Immunodetection of CYP1A1 in colon (A) and liver (B) microsomes from flavonoid treated rats. Electrophoresed microsomal proteins (7.5 μg/well) were transferred to Immobilon-P membrane and probed with antibody against CYP1A1.
Figure 2.Flavonoid structure made of two benzene rings linked by heterocyclic pyrane (a). Square–wave voltammograms of the flavonoids (10 μM) and their structures – quercitrin (b), rutin (c), quercetin (d), chrysin (e) and 100 μM of diosmin (f). Square wave voltammetric parameters were as follows: initial potential 0.0 V, end potential 1.2 V, pulse amplitude 49.85 mV, step potential 1.5 mV, and frequency 100 Hz. Phosphate buffer (0.1 M NaH2PO4 + 0.1 M Na2HPO4, pH 7.0) was used as a supporting electrolyte. For other details see Materials and Methods section.
Figure 3.Influence of different frequencies (A and inset) and step potentials (B and inset) on peak heights and potentials of the flavonoids. For other details see Figure 2.
Figure 4.Influence of pH of Britton-Robinson buffer on peak heights and potentials of the flavonoids (A). Comparison of peak heights of the flavonoids measured in different buffers (B). Dependencies of peak heights and potentials of the flavonoids on different pH values of phosphate buffer (C). Square wave voltammetric parameters were as follows: step potential 1.95 mV, and frequency 180 Hz. For other details see Figure 2.
Figure 5.Dependencies of peak heights of the flavonoids on their different concentrations (A). Influence of human urine on signals of the flavonoids (B): a) electrolyte; b) 1,000 times dilute solution of human urine; c) 5 μM of the flavonoids except diosmin 300 μM; d) 7.5 μM (400 μM); e) 10 μM (500 μM). For other details see Figure 4.
Validation data for the determination of flavonoids (n = 5).
| Quercetin | y = 13.602x + 0.1072 | 0.15 – 5.0 | 0.9988 | 10 | 33 | 3.7 |
| Quercitrin | y = 19.678x + 1.9359 | 0.15 – 5.0 | 0.9992 | 7 | 23 | 1.9 |
| Rutin | y = 15.443x + 1.5354 | 0.15 – 5.0 | 0.9944 | 9 | 30 | 3.6 |
| Chrysin | y = 0.5367x − 0.0841 | 0.15 – 5.0 | 0.9978 | 42 | 140 | 2.2 |
| Diosmin | y = 0.0063x − 0.0187 | 12.5– 200 | 0.9995 | 2,663 | 8,877 | 3.5 |
Correlation coefficient;
Limit of Detections;
Limit of Quantification;
Relative standard deviation (%)