Literature DB >> 28836511

An animal experimental study to assess the core tissue acquisition ability of endoscopic ultrasound-guided histology needles.

Shuntaro Mukai1, Takao Itoi1, Akio Katanuma2, Atsushi Irisawa3.   

Abstract

BACKGROUND AND OBJECTIVES: Acquisition of core tissue on endoscopic ultrasound (EUS)-guided fine-needle aspiration has been regarded as important for establishing an accurate histological diagnosis. Recently, a new 20-gauge histology needle with reverse bevel (ProCore needle) and a 22-gauge needle with 3 novel symmetric heels (Acquire needle) have been developed. The aims of this animal experimental study were to assess the core tissue acquisition (TA) abilities of these new histology needles by comparing them with those of conventional 22-gauge needles and to evaluate the efficacy of suction for these needles.
MATERIALS AND METHODS: Three experienced echoendoscopists performed EUS-guided TA with and without suction using 43 types of needles. The amount of obtained tissue specimens and blood contamination was assessed using a scoring system, and the weight of the obtained tissue specimens was measured using an electronic balance.
RESULTS: The mean amount of core tissue score of the Acquire 22-gauge needle or ProCore 20-gauge needle was significantly higher than that of the conventional 22-gauge needles (Acquire 22-gauge needle vs. conventional 22-gauge needles: P = 0.024; ProCore 20-gauge needle vs. conventional 22-gauge needles: P = 0.001). There was no significant difference in the mean amount of core tissue score between the Acquire 22-gauge needle and the ProCore 20-gauge needle (P = 0.296). In the Acquire 22-gauge needle and ProCore 20-gauge needle, there was no significant difference between the mean amount of core tissue score with suction and that without suction (3.7 ± 0.4 vs. 3.5 ± 0.4, P = 0.734) although blood contamination increased (2.3 ± 0.7 vs. 1.6 ± 0.3, P = 0.061).
CONCLUSION: The TA abilities of the ProCore 20-gauge needle and Acquire 22-gauge needle were better than those of the conventional 22-gauge needles. The efficacy of suction for the ProCore 20-gauge needle and Acquire 22-gauge needle was limited.

Entities:  

Keywords:  Acquire needle; ProCore needle; animal experimental study; endoscopic ultrasound-guided fine-needle aspiration

Year:  2018        PMID: 28836511      PMCID: PMC6106151          DOI: 10.4103/eus.eus_16_17

Source DB:  PubMed          Journal:  Endosc Ultrasound        ISSN: 2226-7190            Impact factor:   5.628


INTRODUCTION

Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a safe and accurate procedure for establishing pathological diagnosis of various intraintestinal and extraintestinal target lesions.[12345] To distinguish between malignant lesions and benign lesions, cytological or histological assessment with a small fragmented tissue is sufficient in most cases. However, the accurate histological diagnosis of a particular tumor or inflammatory diseases such as malignant lymphoma or autoimmune pancreatitis requires histological assessment with a large amount of core tissue and immunohistochemical examinations.[678] Therefore, acquisition of a large amount of core tissue, so-called EUS-guided fine-needle biopsy (EUS-FNB), has been regarded as important for establishing an accurate histological diagnosis. EUS-FNA with a large-caliber 19-gauge needle is recommended for obtaining sufficient core tissue for histological analysis.[9] However, there are some technical issues regarding the use of a 19-gauge needle because its stiffness makes adequate positioning of the scope and manipulation of the needle difficult. Thus, a needle thinner than a 19-gauge needle with good maneuverability, which can obtain a large amount of core tissue with fewer needle passes, is required. Recently, various kinds of needle for EUS-FNB such as a new 20-gauge histology needle with reverse bevel and a 22-gauge needle with novel three symmetric heels have been developed. Herein, we conducted an experiment using animal organs to assess the core tissue acquisition (TA) abilities of these new histology needles by comparing with conventional 22-gauge needles, as well as to evaluate the efficacy of additional application of negative pressure using syringe suction for these needles.

MATERIALS AND METHODS

Animal experiment of endoscopic ultrasound-guided tissue acquisition

Three experienced echoendoscopists (T.I., A.I., and A.K.) performed EUS-guided TA on a porcine liver using a curved linear array echoendoscope (GF-UCT260; Olympus Medical Systems, Tokyo, Japan), which was connected to a processor (EU-ME1; Olympus Medical Systems). EUS-TA was performed under general anesthesia with intubation and ventilation. The following three types of needles (total 4 needles) were evaluated: two conventional 22-gauge needles (Expect SL, Boston Scientific, Natick, MA, USA; EZshot3, Olympus Medical Systems), a new 20-gauge histology needle with reverse bevel (ProCore, Wilson Cook Medical Inc., Winston-Salem, NC) [Figure 1a], and a 22-gauge histology needle with a novel Franseen tip design (Acquire, Boston Scientific) [Figure 1b]. Each echoendoscopist performed two passes of EUS-TA using each needle. One pass was performed with no suction, and the other pass was performed with 20-mL syringe suction force. A total of six tissue specimens obtained by each needle were evaluated. The number of stroke (five times) and the length of stroke in the porcine liver (20 mm) were standardized. The standard stroke method without the door knocking method and fanning technique were used. The obtained tissue specimens were immediately fixed in 10% neutral-buffered formalin solution for histological examination by releasing the syringe and reinserting the stylet. On the following puncture, the puncture point was selected, avoiding the previous puncture site.
Figure 1

(a) The new ProCore 20-gauge histology needle with reverse bevel (Wilson Cook Medical Inc., Winston-Salem, NC). (b) The Acquire 22-gauge histology needle with three novel symmetric heels (Boston Scientific, Natick, MA, USA)

(a) The new ProCore 20-gauge histology needle with reverse bevel (Wilson Cook Medical Inc., Winston-Salem, NC). (b) The Acquire 22-gauge histology needle with three novel symmetric heels (Boston Scientific, Natick, MA, USA)

Specimen handling and histological assessment

The obtained tissue specimens fixed in formalin were brought to the Medical Research Center at Tokyo Medical University. The fixed tissue specimens were processed and embedded in paraffin. Then, the paraffin-embedded tissue specimens were cut into 3 μm slices. Only sections that contained mostly tissue specimen were processed into slides, namely one slide was made for one pass. Thereafter, the tissue specimens in the slides were stained with hematoxylin and eosin for histological examination. In this study, only histological analyses were performed without cytological analyses by a single experienced pathologist blinded to information of used needles. The amount of obtained tissue specimens based on the amount of liver parenchyma was assessed using a scoring system classified into four phases according to the amount of obtained core tissue [Table 1 and Figure 2]. Histologic core tissue was defined as an architecturally intact piece of tissue sufficient for histologic evaluation of the targeted lesion. The core TA ability of each needle was compared in terms of the mean amount of core tissue score. The amount of blood contamination was also assessed using a scoring system classified into three phases.
Table 1

Scoring systems for the amounts of core tissue and blood contamination

Figure 2

(a) Amount of core tissue score 2 (a tissue fragment; a cell cluster). (b) Amount of core tissue score 3 (a small histological core tissue; <×10 objective, field diameter = 2.2 mm). (c) Amount of core tissue score 4 (a large histological core tissue; >×10 objective, filed diameter = 2.2 mm). (d) Amount of blood score 1 (none– few). (e) Amount of blood score 2 (moderate). (f) Amount of blood score 3 (high)

Scoring systems for the amounts of core tissue and blood contamination (a) Amount of core tissue score 2 (a tissue fragment; a cell cluster). (b) Amount of core tissue score 3 (a small histological core tissue; <×10 objective, field diameter = 2.2 mm). (c) Amount of core tissue score 4 (a large histological core tissue; >×10 objective, filed diameter = 2.2 mm). (d) Amount of blood score 1 (none– few). (e) Amount of blood score 2 (moderate). (f) Amount of blood score 3 (high)

Laboratory test of endoscopic ultrasound-guided tissue acquisition

Three experienced echoendoscopists (T.I., A.I., and A.K.) performed EUS-TA on a chicken gizzard placed on a stainless steel tray using the four needles. One pass was performed using each needle following the same method described earlier in the animal experiment of EUS-TA section. The obtained tissue specimens were mounted entirely onto a laboratory dish by reinsertion of the stylet and then weighed using an electronic balance to assess the difference in the weight of the obtained tissue specimens for each needle.

Statistical analysis

The amounts of obtained tissue specimens and blood contamination in the animal experiments were presented as a mean ± standard deviation, and data were compared using the Student's t-test. The differences in the weights of the obtained tissue specimens for the laboratory test were presented as medians and ranges, and these data were analyzed using the Mann–Whitney U-test. Statistical analyses were performed using StatMate III (ATMS, Tokyo, Japan). A P < 0.05 was considered to indicate a statistically significant difference.

RESULTS

The results of the histological assessment for EUS-TA using each needle were as follows. The mean amount of core tissue scores was 2.2 ± 0.5 in the conventional 22-gauge needles (Expect and EZshot3), 3.3 ± 0.5 in the 22-gauge histology needle with a novel Franseen tip design (Acquire 22-gauge needle), and 3.8 ± 0.2 in the new 20-gauge histology needle with reverse bevel (ProCore 20-gauge needle) [Figure 3]. The mean amount of core tissue score of the Acquire 22-gauge needle or ProCore 20-gauge needle was significantly higher than that of the conventional 22-gauge needles (Acquire 22-gauge needle vs. conventional 22-gauge needles: P = 0.024; ProCore 20-gauge needle vs. conventional 22-gauge needles: P = 0.001). On the other hand, there was no significant difference in the mean amount of core tissue score between the Acquire 22-gauge needle and the ProCore 20-gauge needle (P = 0.296).
Figure 3

Comparison of the amount of core tissue scores and standard error among three types of needles for endoscopic ultrasound-guided tissue acquisition

Comparison of the amount of core tissue scores and standard error among three types of needles for endoscopic ultrasound-guided tissue acquisition Regarding the efficacy of additional application of negative pressure using syringe suction, in the conventional 22-gauge needles, the mean amount of core tissue score of EUS-TA with suction was significantly higher than that of EUS-TA without suction (3.0 ± 0.5 vs. 1.3 ± 0.4, P = 0.03) [Figure 4a], although the mean blood score was comparable (1.5 ± 0.3 vs. 1.1 ± 0.2, P = 0.130) [Figure 4b]. On the other hand, in the Acquire 22-gauge needle and ProCore 20-gauge needle, there was no significant difference in the mean amount of core tissue score between EUS-TA with suction and EUS-TA without suction (3.7 ± 0.4 vs. 3.5 ± 0.4, P = 0.734) [Figure 4a], although the blood contamination increased (2.3 ± 0.7 vs. 1.6 ± 0.3, P = 0.061) [Figure 4b].
Figure 4

(a) Comparison of the amount of core tissue scores and standard error between endoscopic ultrasound-guided tissue acquisition with suction and without suction. (b) Comparison of the amount of blood scores and standard error between endoscopic ultrasound-guided tissue acquisition with suction and without suction

(a) Comparison of the amount of core tissue scores and standard error between endoscopic ultrasound-guided tissue acquisition with suction and without suction. (b) Comparison of the amount of blood scores and standard error between endoscopic ultrasound-guided tissue acquisition with suction and without suction Regarding the laboratory test of EUS-TA, the average median weights of the obtained tissue were 2.3 mg (range: 0.7–8.5 mg) in the conventional 22-gauge needles, 4.2 mg (range: 4.0–20.9 mg) in the Acquire 22-gauge needle, and 2.8 mg (range: 2.4–6.8 mg) in the ProCore 20-gauge needle [Figure 5]. There was no significant difference between the weights of tissue obtained using each needle, although those obtained using the Acquire 22-gauge needle and ProCore 20-gauge needle tended to be higher than those obtained using the conventional 22-gauge needles.
Figure 5

Comparison of the weights of the obtained tissue and range among three types of needles for endoscopic ultrasound-guided tissue acquisition

Comparison of the weights of the obtained tissue and range among three types of needles for endoscopic ultrasound-guided tissue acquisition

DISCUSSION

EUS-FNA with cytology has been used as a safe and accurate procedure for establishing a pathological diagnosis of intraluminal or extraluminal lesions since the first report by Vilmann et al. in 1992.[10] Although the high accuracy of EUS-FNA with cytology has been reported, it remains imperfect because of the limited pathological evaluation. Recently, the acquisition of a large amount of core tissue and its histological assessment has become increasingly important to further improve the diagnostic yield of EUS-FNA and to establish an accurate diagnosis with fewer FNA passes. The acquisition of a large amount of histological core tissue has some advantages. First, it enables macroscopic on-site evaluation (MOSE). Although many reports have suggested that rapid on-site evaluation (ROSE) improved the diagnostic accuracy and limited the number of FNA passes required to establish a diagnosis,[111213] the presence of a cytopathologist is not routinely guaranteed because of labor shortages in many centers and even at high-volume centers. Iwashita et al. reported the efficacy of MOSE as an alternative to ROSE.[14] In MOSE, the number of FNA passes is decided on the basis of the macroscopically visible core, which is defined as whitish or yellow pieces of obtained tissue with an apparent bulk. MOSE is useful for estimating specimen adequacy and for reducing the number of FNA passes without the need for ROSE if a visible amount of histological core tissue is obtained. Second, regarding EUS-FNA for solid pancreatic masses, the cytological or histological assessment of a small tissue specimen is generally adequate for the diagnosis of benign or malignant tumors. However, it is occasionally difficult to distinguish between malignancy and chronic pancreatitis or autoimmune pancreatitis, including atypical cells with stromal fibrosis, by cytology or histology of a cell cluster, especially for pathologists who do not specialize in biliopancreatic diseases. A large amount of core tissue including an increase in invasive atypical cells with desmoplastic fibrosis readily enables a pathologist to make a pathological diagnosis of neoplasm. Third, to make an accurate pathological diagnosis of nonepithelial tumors or inflammatory benign diseases such as gastrointestinal stromal tumor, malignant lymphoma, or autoimmune pancreatitis, tissue architecture evaluation and immunohistochemical staining assessment are required.[1516] A large amount of core tissue enables not only hematoxylin and eosin staining but also additional immunohistochemical examinations or flow cytometric and cytogenetic assessments. Fourth, current advances in basic medical science have enabled the development and clinical application of molecular targeting and the assessment of molecular markers or DNA profiling, indicating resistance and the effects of anticancer chemotherapy or patient prognosis.[17] A small amount of obtained tissue is not suitable for the assessment of molecular expression by immunohistochemical staining or DNA sequencing. If personalized medical treatment according to individualized molecular profiling will be developed in the future, the importance of accurately obtaining a sufficiently large amount of core tissue by EUS-FNA in 1 session would increase. Recent developments of biopsy needles or the FNA technique have been initiated to obtain a large amount of core tissue.[1819] EUS-FNA with a 19-gauge needle has been reported to obtain a histological core tissue and yield a significantly higher diagnostic accuracy. However, a technical limitation of a 19-gauge needle is that it is stiffer than a 22-gauge needle or a 25-gauge needle which can restrict the positioning and angulation of the scope and elevator function.[20] To adequately obtain a core tissue, the ProCore needle has been developed. This is a uniquely designed needle with reverse bevel that hooks and cuts the tissue and traps it in the needle during the FNA motion. However, in their systematic review and meta-analysis comparing the performance of the ProCore needle with that of conventional FNA needles, Bang et al. found no difference in sample adequacy, diagnostic accuracy, or core TA ability.[21] Thus, a new 20-gauge ProCore needle has been designed, which may be a good compromise between the ease of use of a 22-gauge needle and the high TA ability of a 19-gauge needle. In the present animal experiments, the amount of core tissue obtained by the ProCore 20-guage needle was larger than that by the other 22-gauge needles. However, the flexibility of the ProCore 20-guage needle was not evaluated because only transgastric puncture was performed. In our subsequent clinical trial, the technical acceptability of transduodenal puncture would be evaluated. The recently developed Acquire 22-gauge needle, which is called a Franseen needle, has three symmetric heels designed to maximize tissue capture and minimize fragmentation. This needle was developed to adequately obtain a core tissue and improve the diagnostic yield. Although many different types of needles are currently available, the most widely used needle type is the end-cut type needle with beveled tips. To appropriately acquire core tissue, it is important to not only cut the tissue but also collect the tissue in the needle tract. Therefore, in core TA using an end-cut type needle, the tissue should be cut with not only the beveled side but also the buffed heel. As it may be more difficult to cut the tissue with the buffed heel, higher puncture speed and axial force are required.[18] In this respect, the three symmetric heels of the Acquire 22-gauge needle are very well designed enabling easy tissue collection in the needle tract even if only the needle penetrates the target lesion. In the present animal experiments, the mean amount of core tissue score of the Acquire 22-gauge needle was comparable to that of the ProCore 20-gauge needle and significantly higher than that of the conventional 22-gauge needles. Although an increase in adverse events such as bleeding may be a concern, the Acquire 22-gauge needle is promising as a first choice needle for EUS-FNA. What remains controversial is the efficacy of negative pressure by suction during EUS-FNA. It has been reported that negative pressure by suction can increase the amount of obtained specimen.[22] However, it has potential to increase blood contamination, which may hinder pathological interpretation.[23] In a previous bench-top experiment of suction forces generated through FNA needles, Katanuma et al. demonstrated that suction force was applied to a needle according to the needle diameter or syringe size.[24] The clinical efficacy of suction might differ depending on the needle type or the target lesions. In the present animal experiments, the mean amount of core tissue score of the conventional 22-gauge needles with suction was significantly higher than that of the conventional 22-gauge needles without suction. This indicates that in the conventional 22-gauge needles, suction is useful for increasing the amount of tissue obtained from the target lesion (i.e., porcine liver), although blood contamination may increase to some extent. On the other hand, the mean amount of core tissue score of the ProCore 20-gauge needle or Acquire 22-gauge needle was the same between EUS-FNA with suction and EUS-FNA without suction. From these results, it is considered that the efficacy of suction may be limited to needles with a high TA ability. Suction may also have the potential to produce an opposite effect because of an increase in blood contamination.

CONCLUSION

The present animal experiments showed that the TA abilities of the ProCore 20-gauge needle and Acquire 22-gauge needle were better than those of the conventional 22-gauge needles. However, the efficacy of additional application of negative pressure using syringe suction of the ProCore 20-gauge needle and Acquire 22-gauge needle was limited. As a limitation, this study involved animal experiments in which the conditions might differ from those in clinical practice. Subsequent studies should investigate the efficacy and safety of the ProCore 20-gauge needle and Acquire 22-gauge needle in the clinical setting.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  24 in total

1.  Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders: feasibility of immunohistological, flow cytometric, and cytogenetic assessments.

Authors:  Ichiro Yasuda; Naoe Goto; Hisashi Tsurumi; Masanori Nakashima; Shinpei Doi; Takuji Iwashita; Nobuhiro Kanemura; Senji Kasahara; Seiji Adachi; Takeshi Hara; Masahito Shimizu; Tsuyoshi Takami; Hisataka Moriwaki
Journal:  Am J Gastroenterol       Date:  2011-10-11       Impact factor: 10.864

2.  Multicenter, prospective, crossover trial comparing the door-knocking method with the conventional method for EUS-FNA of solid pancreatic masses (with videos).

Authors:  Shuntaro Mukai; Takao Itoi; Reiko Ashida; Takayoshi Tsuchiya; Nobuhito Ikeuchi; Kentaro Kamada; Reina Tanaka; Junko Umeda; Ryosuke Tonozuka; Nobuyasu Fukutake; Koki Hoshi; Fuminori Moriyasu; Takuji Gotoda; Atsushi Irisawa
Journal:  Gastrointest Endosc       Date:  2015-10-30       Impact factor: 9.427

3.  Use of samples from endoscopic ultrasound-guided 19-gauge fine-needle aspiration in diagnosis of autoimmune pancreatitis.

Authors:  Takuji Iwashita; Ichiro Yasuda; Shinpei Doi; Nobuhiro Ando; Masanori Nakashima; Seiji Adachi; Yoshinobu Hirose; Tsuyoshi Mukai; Keisuke Iwata; Eiichi Tomita; Takao Itoi; Hisataka Moriwaki
Journal:  Clin Gastroenterol Hepatol       Date:  2011-10-20       Impact factor: 11.382

4.  Histological diagnosis by EUS-guided fine-needle aspiration biopsy in pancreatic solid masses without on-site cytopathologist: a single-center experience.

Authors:  Takao Itoi; Takayoshi Tsuchiya; Fumihide Itokawa; Atsushi Sofuni; Toshio Kurihara; Shujiro Tsuji; Nobuhito Ikeuchi
Journal:  Dig Endosc       Date:  2011-05       Impact factor: 7.559

5.  Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

Authors:  J-M Dumonceau; M Polkowski; A Larghi; P Vilmann; M Giovannini; J-L Frossard; D Heresbach; B Pujol; G Fernández-Esparrach; E Vazquez-Sequeiros; A Ginès
Journal:  Endoscopy       Date:  2011-08-12       Impact factor: 10.093

6.  Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses.

Authors:  Julio Iglesias-Garcia; J Enrique Dominguez-Munoz; Ihab Abdulkader; Jose Larino-Noia; Elena Eugenyeva; Antonio Lozano-Leon; Jeronimo Forteza-Vila
Journal:  Am J Gastroenterol       Date:  2011-04-12       Impact factor: 10.864

7.  EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.

Authors:  Pujan Kandel; Ghassan Tranesh; Aziza Nassar; Russell Bingham; Massimo Raimondo; Timothy A Woodward; Victoria Gomez; Michael B Wallace
Journal:  Gastrointest Endosc       Date:  2016-03-24       Impact factor: 9.427

8.  EUS-guided fine-needle tissue acquisition by using a 19-gauge needle in a selected patient population: a prospective study.

Authors:  Alberto Larghi; Elizabeth C Verna; Riccardo Ricci; Tom C Seerden; Domenico Galasso; Antonella Carnuccio; Naohito Uchida; Guido Rindi; Guido Costamagna
Journal:  Gastrointest Endosc       Date:  2011-09       Impact factor: 9.427

9.  Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope.

Authors:  K F Binmoeller; R Thul; V Rathod; P Henke; B Brand; H C Jabusch; N Soehendra
Journal:  Gastrointest Endosc       Date:  1998-02       Impact factor: 9.427

Review 10.  A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition.

Authors:  Ji Young Bang; Robert Hawes; Shyam Varadarajulu
Journal:  Endoscopy       Date:  2015-11-12       Impact factor: 10.093

View more
  9 in total

1.  Histologic retrieval rate of a newly designed side-bevelled 20G needle for EUS-guided tissue acquisition of solid pancreatic lesions.

Authors:  Elia Armellini; Erminia Manfrin; Elena Trisolini; Silvano Andorno; Marco Ballarè; Laura Bernardoni; Renzo Luciano Boldorini; Armando Gabbrielli; Luca Frulloni; Alberto Larghi; Pietro Occhipinti; Aldo Scarpa; Stefano Francesco Crinò
Journal:  United European Gastroenterol J       Date:  2018-09-30       Impact factor: 4.623

Review 2.  Diagnostic Endoscopic Ultrasound: Technique, Current Status and Future Directions.

Authors:  Tiing Leong Ang; Andrew Boon Eu Kwek; Lai Mun Wang
Journal:  Gut Liver       Date:  2018-09-15       Impact factor: 4.519

3.  A retrospective histological comparison of EUS-guided fine-needle biopsy using a novel franseen needle and a conventional end-cut type needle.

Authors:  Shuntaro Mukai; Takao Itoi; Hiroshi Yamaguchi; Atsushi Sofuni; Takayoshi Tsuchiya; Reina Tanaka; Ryosuke Tonozuka; Mitsuyoshi Honjo; Mitsuru Fujita; Kenjiro Yamamoto; Yukitoshi Matsunami; Yasutsugu Asai; Takashi Kurosawa; Yuichi Nagakawa
Journal:  Endosc Ultrasound       Date:  2019 Jan-Feb       Impact factor: 5.628

4.  Prospective, multicenter, observational study of tissue acquisition through EUS-guided fine-needle biopsy using a 25G Franseen needle.

Authors:  Ryo Sugiura; Masaki Kuwatani; Kei Yane; Yoko Taya; Hideyuki Ihara; Manabu Onodera; Kazunori Eto; Itsuki Sano; Taiki Kudo; Tomoko Mitsuhashi; Akio Katanuma; Naoya Sakamoto
Journal:  Endosc Ultrasound       Date:  2019 Sep-Oct       Impact factor: 5.628

5.  Effectiveness of introducing a 20-gauge core biopsy needle with a core trap in EUS-FNA/B for diagnosing pancreatic cancer.

Authors:  Shunsuke Watanabe; Jun Miyoshi; Masao Toki; Komei Kambayashi; Shuichi Kitada; Takeshi Nosaka; Tomoyuki Goto; Hirotaka Ota; Kazushige Ochiai; Koichi Gondo; Nobuhito Ikeuchi; Shujiro Tsuji; Kenji Nakamura; Junji Shibahara; Tadakazu Hisamatsu
Journal:  BMC Gastroenterol       Date:  2021-01-06       Impact factor: 3.067

Review 6.  Creating Logical Flow When Writing Scientific Articles.

Authors:  Edward Barroga; Glafera Janet Matanguihan
Journal:  J Korean Med Sci       Date:  2021-10-18       Impact factor: 2.153

7.  Comparison of Fork-tip and Franseen needles for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions: A propensity-matched analysis.

Authors:  Akashi Fujita; Shomei Ryozawa; Yuki Tanisaka; Tomoya Ogawa; Yoichi Saito; Hiromune Katsuda; Kazuya Miyaguchi; Masanori Yasuda; Ryuichiro Araki; Yumi Mashimo; Tomoaki Tashima; Yuya Nakano; Rie Terada; Ryuhei Jinushi; Masafumi Mizuide
Journal:  DEN open       Date:  2022-06-28

8.  Histopathological evaluation of needle tract seeding caused by EUS-fine-needle biopsy based on resected specimens from patients with solid pancreatic masses: An analysis of 73 consecutive cases.

Authors:  Ryosuke Nakatsubo; Kenjiro Yamamoto; Takao Itoi; Atsushi Sofuni; Takayoshi Tsuchiya; Kentaro Ishii; Reina Tanaka; Ryosuke Tonozuka; Shuntaro Mukai; Kazumasa Nagai; Hiroshi Yamaguchi; Yuichi Nagakawa
Journal:  Endosc Ultrasound       Date:  2021 May-Jun       Impact factor: 5.628

9.  EUS-FNA Biopsies to Guide Precision Medicine in Pancreatic Cancer: Results of a Pilot Study to Identify KRAS Wild-Type Tumours for Targeted Therapy.

Authors:  Joanne Lundy; Marion Harris; John Zalcberg; Allan Zimet; David Goldstein; Val Gebski; Adina Borsaru; Christopher Desmond; Michael Swan; Brendan J Jenkins; Daniel Croagh
Journal:  Front Oncol       Date:  2021-12-09       Impact factor: 6.244

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.