BACKGROUND: Previous studies have reported on endoscopic ultrasound-guided, fine needle aspiration biopsy using 22- to 25-gauge needles. We evaluated the histologic and cytologic yield of endoscopic ultrasound-guided, fine needle aspiration biopsy of the pancreas using an 18-gauge, Menghini-type core needle.
METHODS: Fine needle aspiration biopsy was performed in conjunction with a prototype 2.8 mm channel convex array echoendoscope. The core specimen was placed in formalin for cell block, and residual material was expelled on slides for cytology. Definitive diagnosis was established by surgery or clinical follow-up.
RESULTS: Of 45 patients who underwent fine needle aspiration biopsy, the needle failed to penetrate indurated pancreatic lesions in five. An average of 2.6 passes were performed in the remaining patients. Sufficient material for a histologic and/or cytologic diagnosis was obtained in 40 patients (histologic and cytologic yield of 68% and 75%, respectively). Combining the results of histology and cytology, the sensitivity and specificity for detection of malignancy was 76% and 100%, respectively. Histology confirmed the cytologic findings in 35 patients, providing additional tissue specific information. In three cases histology established a diagnosis of malignancy where cytology was not conclusively malignant. However, in three cases of surgically confirmed malignancy histology failed to detect malignancy, whereas cytology showed suspicious or malignant cells. The sensitivity of histology and cytology alone in detecting malignancy was 53% and 70%, respectively. Mild pancreatitis occurred after pancreatic fine needle aspiration biopsy in one patient.
CONCLUSION: Core specimens for histology can be safely obtained using an 18-gauge needle. Histology provides tissue-specific information that complements cytology, but histology is less sensitive than cytology in detecting malignancy.

Entities:  

Mesh:

Year:  1998        PMID: 9512275     DOI: 10.1016/s0016-5107(98)70343-8

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  29 in total

Review 1.  Endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic adenocarcinoma.

Authors:  Kyung W Noh; Michael B Wallace
Journal:  MedGenMed       Date:  2005-05-25

2.  Changing trends in endosonography: linear imaging and tissue are increasingly the issue.

Authors:  Kyung W Noh; Timothy A Woodward; Massimo Raimondo; Alan D Savoy; Surakit Pungpapong; Joy D Hardee; Michael B Wallace
Journal:  Dig Dis Sci       Date:  2007-03-01       Impact factor: 3.199

3.  Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses.

Authors:  Julio Iglesias-Garcia; Enrique Dominguez-Munoz; Antonio Lozano-Leon; Ihab Abdulkader; Jose Larino-Noia; Jose Antunez; Jeronimo Forteza
Journal:  World J Gastroenterol       Date:  2007-01-14       Impact factor: 5.742

Review 4.  Rapid on-site evaluation increases endoscopic ultrasound-guided fine-needle aspiration adequacy for pancreatic lesions.

Authors:  Robert L Schmidt; Benjamin L Witt; Anna P Matynia; Gonzalo Barraza; Lester J Layfield; Douglas G Adler
Journal:  Dig Dis Sci       Date:  2012-10-04       Impact factor: 3.199

5.  Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses.

Authors:  M Voss; P Hammel; G Molas; L Palazzo; A Dancour; D O'Toole; B Terris; C Degott; P Bernades; P Ruszniewski
Journal:  Gut       Date:  2000-02       Impact factor: 23.059

6.  Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis.

Authors:  Masato Matsuyama; Hiroshi Ishii; Kensuke Kuraoka; Seigo Yukisawa; Akiyoshi Kasuga; Masato Ozaka; Sho Suzuki; Kouichi Takano; Yuko Sugiyama; Takao Itoi
Journal:  World J Gastroenterol       Date:  2013-04-21       Impact factor: 5.742

7.  Rare pancreatic neoplasms: the utility of endoscopic ultrasound-guided fine-needle aspiration-a large single center study.

Authors:  Hiroshi Imaoka; Kenji Yamao; Vikram Bhatia; Yasuhiro Shimizu; Yasushi Yatabe; Takashi Koshikawa; Yoshikazu Kinoshita
Journal:  J Gastroenterol       Date:  2009-02-13       Impact factor: 7.527

8.  The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis.

Authors:  S Hébert-Magee; S Bae; S Varadarajulu; J Ramesh; A R Frost; M A Eloubeidi; I A Eltoum
Journal:  Cytopathology       Date:  2013-06       Impact factor: 2.073

Review 9.  Clinical approach to the patient with a solid pancreatic mass.

Authors:  Reinhold Függer; Odo Gangl; Uwe Fröschl
Journal:  Wien Med Wochenschr       Date:  2014-02-28

10.  Ultrasound-guided percutaneous pancreatic tumor biopsy in pancreatic cancer: a comparison with metastatic liver tumor biopsy, including sensitivity, specificity, and complications.

Authors:  Junichi Matsubara; Takuji Okusaka; Chigusa Morizane; Masafumi Ikeda; Hideki Ueno
Journal:  J Gastroenterol       Date:  2008-03-29       Impact factor: 7.527

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.