Literature DB >> 28821929

Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols.

Thomas Bayer1, Werner Adler2, Rolf Janka3, Michael Uder3, Frank Roemer3.   

Abstract

OBJECTIVE: To study the feasibility of magnetic resonance cinematography of the fingers (MRCF) with comparison of image quality of different protocols for depicting the finger anatomy during motion.
MATERIALS AND METHODS: MRCF was performed during a full flexion and extension movement in 14 healthy volunteers using a finger-gating device. Three real-time sequences (frame rates 17-59 images/min) and one proton density (PD) sequence (3 images/min) were acquired during incremental and continuous motion. Analyses were performed independently by three readers. Qualitative image analysis included Likert-scale grading from 0 (useless) to 5 (excellent) and specific visual analog scale (VAS) grading from 0 (insufficient) to 100 (excellent). Signal-to-noise calculation was performed. Overall percentage agreement and mean absolute disagreement were calculated.
RESULTS: Within the real-time sequences a high frame-rate true fast imaging with steady-state free precession (TRUFI) yielded the best image quality with Likert and overall VAS scores of 3.0 ± 0.2 and 60.4 ± 25.3, respectively. The best sequence regarding image quality was an incremental PD with mean values of 4.8 ± 0.2 and 91.2 ± 9.4, respectively. Overall percentage agreement and mean absolute disagreement were 47.9 and 0.7, respectively. No statistically significant SNR differences were found between continuous and incremental motion for the real-time protocols.
CONCLUSION: MRCF is feasible with appropriate image quality during continuous motion using a finger-gating device. Almost perfect image quality is achievable with incremental PD imaging, which represents a compromise for MRCF with the drawback of prolonged scanning time.

Entities:  

Keywords:  Cinematography; Finger; MRI; Pulley rupture; Volar plate

Mesh:

Year:  2017        PMID: 28821929     DOI: 10.1007/s00256-017-2742-2

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  18 in total

1.  MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study.

Authors:  J Barkhausen; S G Ruehm; M Goyen; T Buck; G Laub; J F Debatin
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study.

Authors:  Nasreddin D Abolmaali; Jan Schmitt; Wolfram Schwarz; Douglas E Toll; Stefan Hinterwimmer; Thomas J Vogl
Journal:  Eur Radiol       Date:  2004-07-29       Impact factor: 5.315

3.  Balanced steady-state free precession vs. segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla.

Authors:  Frank Grothues; Hagen Boenigk; Joachim Graessner; Martin Kanowski; Helmut U Klein
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

Review 4.  Kinematic magnetic resonance imaging of the joints: techniques and clinical applications.

Authors:  F G Shellock; J H Mink; A Deutsch; B D Pressman
Journal:  Magn Reson Q       Date:  1991-04

5.  Biomechanics of the volar plate of the proximal interphalangeal joint: a dynamic ultrasonographic study.

Authors:  Susumu Saito; Yoshihisa Suzuki
Journal:  J Hand Surg Am       Date:  2011-02       Impact factor: 2.230

Review 6.  MR imaging of temporomandibular joint dysfunction: a pictorial review.

Authors:  Xavier Tomas; Jaume Pomes; Juan Berenguer; Llorenç Quinto; Carlos Nicolau; Josep Maria Mercader; Vicente Castro
Journal:  Radiographics       Date:  2006 May-Jun       Impact factor: 5.333

7.  Kinematic MR imaging of the ankle--initial results with ultra-fast sequence imaging.

Authors:  C Muhle; G Brinkmann; J Brossmann; F Wesner; M Heller
Journal:  Acta Radiol       Date:  1997-09       Impact factor: 1.990

8.  Patellofemoral joint: identification of abnormalities with active-movement, "unloaded" versus "loaded" kinematic MR imaging techniques.

Authors:  F G Shellock; J H Mink; A L Deutsch; T K Foo; P Sullenberger
Journal:  Radiology       Date:  1993-08       Impact factor: 11.105

9.  Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study.

Authors:  Jean-Christophe Lasalarie; Jean-Michel Serfaty; Christophe Carre; David Messika-Zeitoun; Christophe Jeannot; Elisabeth Schouman-Claeys; Jean-Pierre Laissy
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

10.  Dynamic Three-Dimensional Shoulder Mri during Active Motion for Investigation of Rotator Cuff Diseases.

Authors:  Christine Tempelaere; Jérome Pierrart; Marie-Martine Lefèvre-Colau; Valérie Vuillemin; Charles-André Cuénod; Ulrich Hansen; Olivier Mir; Wafa Skalli; Thomas Gregory
Journal:  PLoS One       Date:  2016-07-19       Impact factor: 3.240

View more
  2 in total

Review 1.  Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences.

Authors:  Marc Garetier; Bhushan Borotikar; Karim Makki; Sylvain Brochard; François Rousseau; Douraïed Ben Salem
Journal:  Insights Imaging       Date:  2020-05-19

2.  Assessment of vocal fold mobility using dynamic magnetic resonance imaging and ultrasound in healthy volunteers.

Authors:  Magdalena Derlatka-Kochel; Pawel Kumoniewski; Marcin Majos; Kamil Ludwisiak; Lech Pomorski; Agata Majos
Journal:  Pol J Radiol       Date:  2019-09-25
  2 in total