| Literature DB >> 31969952 |
Magdalena Derlatka-Kochel1, Pawel Kumoniewski2, Marcin Majos3, Kamil Ludwisiak1, Lech Pomorski2, Agata Majos1.
Abstract
PURPOSE: To verify the value of dynamic magnetic resonance imaging (MRI) sequences, fast field echo (FFE), and balanced gradient echo (true fast imaging with steady-state free precession - TRUFI) in the evaluation of vocal fold mobility in healthy volunteers, against ultrasound examination (US) as the reference test.Entities:
Keywords: magnetic resonance; mobility; ultrasound; vocal cords; vocal folds
Year: 2019 PMID: 31969952 PMCID: PMC6964356 DOI: 10.5114/pjr.2019.89122
Source DB: PubMed Journal: Pol J Radiol ISSN: 1733-134X
Figure 1Ultrasonography – measurement of the minimum (A) and maximum (B) angle between the vocal fold and the midline during normal breathing
Figure 2Ultrasonography – vocal folds during voice emission
Parameters of obtained dynamic and static sequences
| Type of sequence | Dynamic examination | Static examination | ||
|---|---|---|---|---|
| FFE | Balanced GE (TRUFI) | IR (TIRM) | TSE | |
| Repetition time (ms) | 23 | 364.76 | 3440 | 3600 |
| Echo time (ms) | 3.64 | 1.29 | 76 | 82 |
| Image resolution | 1.1 x 1.1 | 1.4 x 1.1 | 0.9 x 0.9 | 0.8 x 0.8 |
| Slice thickness | 6 | 10 | 3 | 4 |
| Number of slices | 3 | 1 | 25 | 45 |
| Flip angle | 20 | 62 | 150 | 127 |
| Field of view (mm) | 220 x 220 | 280 x 280 | 220 x 220 | 210 x 210 |
| Total acquisition time | 1:08 | 0:22 | 4:42 | 3:43 |
| Number of dynamic scans | 15 | 60 | Not applicable | Not applicable |
Figure 3A) Pilot sagittal sequence. B) Coronal turbo inversion recovery magnitude (TIRM) sequence. Identification of a plane for dynamic magnetic resonance imaging
Figure 4Rima glottidis on dynamic magnetic resonance imaging sequences: A-B) fast field echo (FFE) and C-D) true fast imaging with steady-state free precession (TRUFI) during normal breathing
Figure 5Dynamic true fast imaging with steady-state free precession (TRUFI) sequence, axial slices. Representative measurements of the glottic angle (A) and rima glottidis area (B)
Mean values of minimum and maximum glottic angles during normal breathing
| Parameter | Minimum angle (°) | Maximum angle (°) | ||||
|---|---|---|---|---|---|---|
| USG | FFE MRI | TRUFI MRI | USG | FFE MRI | TRUFI MRI | |
| Whole group | 7.17 ± 1.69 | 9.54 ± 3.18 | 8.11 ± 2.14 | 17.09 ± 4.00 | 16.63 ± 4.46 | 17.46 ± 3.73 |
| Women | 7.35 ± 1.57 (Me = 7) | 9.55 ± 3.36 | 7.95 ± 2.21 | 17.00 ± 3.85 | 16.95 ± 4.05 | 17.95 ± 3.17 |
| Men | 6.93 ± 1.87 | 9.53 ± 3.02 | 8.33 ± 2.09 | 17.20 ± 4.33 | 16.20 ± 5.07 | 16.80 ± 4.40 |
Mean values of minimum and maximum rima glottidis area during normal breathing determined based on dynamic magnetic resonance imaging sequences
| Parameter | Minimum area (cm2) | Maximum area (cm2) | ||
|---|---|---|---|---|
| FFE MRI | TRUFI MRI | FFE MRI | TRUFI MRI | |
| Whole group | 0.36 ± 0.15 (Me = 0.30) | 0.26 ± 0.11 (Me = 0.25) | 0.62 ± 0.21 (Me = 0.60) | 0.67 ± 0.20 (Me = 0.60) |
| Women | 0.23 ± 0.08 (Me = 0.30) | 0.20 ± 0.09 (Me = 0.20) | 0.48 ± 0.10 (Me = 0.50) | 0.56 ± 0.16 (Me = 0.53) |
| Men | 0.47 ± 0.15 (Me = 0.45) | 0.34 ± 0.10 (Me = 0.35) | 0.81 ± 0.17 (Me = 0.80) | 0.78 ± 0.19 (Me = 0.80) |