Literature DB >> 28812247

Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

Christina Pahl1,2, Henning Ebelt3, Mostafa Sayahkarajy4, Eko Supriyanto5, Amiliana Soesanto6.   

Abstract

This paper proposes a robotic Transesophageal Echocardiography (TOE) system concept for Catheterization Laboratories. Cardiovascular disease causes one third of all global mortality. TOE is utilized to assess cardiovascular structures and monitor cardiac function during diagnostic procedures and catheter-based structural interventions. However, the operation of TOE underlies various conditions that may cause a negative impact on performance, the health of the cardiac sonographer and patient safety. These factors have been conflated and evince the potential of robot-assisted TOE. Hence, a careful integration of clinical experience and Systems Engineering methods was used to develop a concept and physical model for TOE manipulation. The motion of different actuators of the fabricated motorized system has been tested. It is concluded that the developed medical system, counteracting conflated disadvantages, represents a progressive approach for cardiac healthcare.

Entities:  

Keywords:  Catheterization laboratory; Ergonomics; Heart; Manipulator; Transesophageal echocardiography; Usability

Mesh:

Year:  2017        PMID: 28812247     DOI: 10.1007/s10916-017-0786-4

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  33 in total

1.  Esophageal echocardiography.

Authors:  L Frazin; J V Talano; L Stephanides; H S Loeb; L Kopel; R M Gunnar
Journal:  Circulation       Date:  1976-07       Impact factor: 29.690

2.  Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists.

Authors:  Rebecca T Hahn; Theodore Abraham; Mark S Adams; Charles J Bruce; Kathryn E Glas; Roberto M Lang; Scott T Reeves; Jack S Shanewise; Samuel C Siu; William Stewart; Michael H Picard
Journal:  J Am Soc Echocardiogr       Date:  2013-09       Impact factor: 5.251

3.  Nosocomial outbreak of multidrug-resistant Pseudomonas aeruginosa caused by damaged transesophageal echocardiogram probe used in cardiovascular surgical operations.

Authors:  Masafumi Seki; Hisako Machida; Naoko Machida; Yoshiaki Yamagishi; Hisao Yoshida; Kazunori Tomono
Journal:  J Infect Chemother       Date:  2013-01-05       Impact factor: 2.211

4.  ERCP and fluoroscopy time.

Authors:  Amer A Alkhatib; Ala Abdel Jalil; M E Harrison
Journal:  Am J Gastroenterol       Date:  2014-03       Impact factor: 10.864

5.  A system for ultrasonically imaging the human heart in three dimensions.

Authors:  D L Dekker; R L Piziali; E Dong
Journal:  Comput Biomed Res       Date:  1974-12

6.  Application of transesophageal echocardiography to continuous intraoperative monitoring of left ventricular performance.

Authors:  M Matsumoto; Y Oka; J Strom; W Frishman; A Kadish; R M Becker; R W Frater; E H Sonnenblick
Journal:  Am J Cardiol       Date:  1980-07       Impact factor: 2.778

Review 7.  Economics of psychosocial factors in patients with cardiovascular disease.

Authors:  Benjamin A Rodwin; Tanya M Spruill; Joseph A Ladapo
Journal:  Prog Cardiovasc Dis       Date:  2013-04-09       Impact factor: 8.194

8.  Transcatheter aortic valve replacement in Europe: adoption trends and factors influencing device utilization.

Authors:  Darren Mylotte; Ruben L J Osnabrugge; Stephan Windecker; Thierry Lefèvre; Peter de Jaegere; Raban Jeger; Peter Wenaweser; Francesco Maisano; Neil Moat; Lars Søndergaard; Johan Bosmans; Rui C Teles; Giuseppe Martucci; Ganesh Manoharan; Eulogio Garcia; Nicolas M Van Mieghem; A Pieter Kappetein; Patrick W Serruys; Ruediger Lange; Nicolo Piazza
Journal:  J Am Coll Cardiol       Date:  2013-05-15       Impact factor: 24.094

9.  An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures.

Authors:  O W E Morrish; K E Goldstone
Journal:  Br J Radiol       Date:  2007-11-26       Impact factor: 3.039

10.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures.

Authors:  Koichi Chida; Haruo Saito; Hiroki Otani; Masahiro Kohzuki; Shoki Takahashi; Shogo Yamada; Kunio Shirato; Masayuki Zuguchi
Journal:  AJR Am J Roentgenol       Date:  2006-03       Impact factor: 3.959

View more