Literature DB >> 23292134

Nosocomial outbreak of multidrug-resistant Pseudomonas aeruginosa caused by damaged transesophageal echocardiogram probe used in cardiovascular surgical operations.

Masafumi Seki1, Hisako Machida, Naoko Machida, Yoshiaki Yamagishi, Hisao Yoshida, Kazunori Tomono.   

Abstract

Multidrug-resistant Pseudomonas aeruginosa (MDRP) is a major problem among hospital-acquired infections. We had a one-month outbreak of this strain at a university hospital in Osaka, Japan, from May to June 2004. To determine the cause of the outbreak, we collected and analyzed epidemiological information about the patients from whom MDRP was isolated, and performed microbiological investigations. MDRP was detected in respiratory specimens from eight patients in the intensive care unit. One of these patients developed severe lethal pneumonia accompanied by septicemia, and two contracted less severe non-lethal pneumonia. All the MDRP patients had been monitored with a contaminated transesophageal echocardiography (TOE) probe during their cardiac surgery. The TOE probe proved to have a defect 5 mm in diameter at the surface near the transducer, and the MDRP strain was traced to this defect. Pulsed-field gel electrophoresis showed that the strain isolated from the patients and from the TOE probe were genetically indistinguishable. After use of the damaged TOE probe was terminated, MDRP was not isolated from any patients who underwent cardiac surgery in the subsequent 8 years. In conclusion, TOE is routinely used during cardiac surgery and has been shown to have a significant clinical effect. Prevention of similar post-operative pneumonia outbreaks will require thorough infection control of TOE probes used for monitoring during cardiovascular surgery.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23292134     DOI: 10.1007/s10156-012-0542-0

Source DB:  PubMed          Journal:  J Infect Chemother        ISSN: 1341-321X            Impact factor:   2.211


  11 in total

1.  Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

Authors:  Christina Pahl; Henning Ebelt; Mostafa Sayahkarajy; Eko Supriyanto; Amiliana Soesanto
Journal:  J Med Syst       Date:  2017-08-15       Impact factor: 4.460

Review 2.  The Role of Environmental Contamination in the Transmission of Nosocomial Pathogens and Healthcare-Associated Infections.

Authors:  Geehan Suleyman; George Alangaden; Ana Cecilia Bardossy
Journal:  Curr Infect Dis Rep       Date:  2018-04-27       Impact factor: 3.725

3.  [Intraoperative transesophageal echocardiography as monitoring procedure in noncardiac surgery patients].

Authors:  V Umrath; C Dumps; B Rupprecht; J Schimpf; J Benak
Journal:  Anaesthesist       Date:  2021-11-11       Impact factor: 1.041

4.  Emergence and prevention measures for multidrug resistant Pseudomonas aeruginosa in catheter-associated urinary tract infection in spinal cord injury patients.

Authors:  K Shigemura; R Takase; K Osawa; K Takaba; M Nomi; M Fujisawa; S Arakawa
Journal:  Spinal Cord       Date:  2014-09-02       Impact factor: 2.772

5.  Validation of a phage-open reading frame typing kit for rapid identification of methicillin-resistant Staphylococcus aureus (MRSA) transmission in a tertiary hospital.

Authors:  Hiroki Takahashi; Masafumi Seki; Norihisa Yamamoto; Shigeto Hamaguchi; Masahiro Ojima; Tomoya Hirose; Kazuhisa Yoshiya; Masahiro Toyokawa; Isao Nishi; Hiroshi Ogura; Takeshi Shimazu; Kazunori Tomono
Journal:  Infect Drug Resist       Date:  2015-05-14       Impact factor: 4.003

6.  Community-acquired, hospital-acquired, and healthcare-associated pneumonia caused by Pseudomonas aeruginosa.

Authors:  Ayumi Fujii; Masafumi Seki; Masachika Higashiguchi; Isao Tachibana; Atsushi Kumanogoh; Kazunori Tomono
Journal:  Respir Med Case Rep       Date:  2014-03-26

Review 7.  Bacterial contamination of inanimate surfaces and equipment in the intensive care unit.

Authors:  Vincenzo Russotto; Andrea Cortegiani; Santi Maurizio Raineri; Antonino Giarratano
Journal:  J Intensive Care       Date:  2015-12-10

8.  Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology.

Authors:  Christiane Marita Nyhsen; Hilary Humphreys; Carlos Nicolau; Gerhard Mostbeck; Michel Claudon
Journal:  Insights Imaging       Date:  2016-10-24

9.  Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group.

Authors:  Christiane M Nyhsen; Hilary Humphreys; Roland J Koerner; Nicolas Grenier; Adrian Brady; Paul Sidhu; Carlos Nicolau; Gerhard Mostbeck; Mirko D'Onofrio; Afshin Gangi; Michel Claudon
Journal:  Insights Imaging       Date:  2017-11-27

10.  Risk of infection following semi-invasive ultrasound procedures in Scotland, 2010 to 2016: A retrospective cohort study using linked national datasets.

Authors:  David Scott; Eilidh Fletcher; Hayley Kane; William Malcolm; Kimberley Kavanagh; A-Lan Banks; Annette Rankin
Journal:  Ultrasound       Date:  2018-05-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.