Literature DB >> 28801824

Two-dimensional capillary zone electrophoresis-mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products.

Kevin Jooß1,2, Jens Hühner1,3, Steffen Kiessig4, Bernd Moritz4, Christian Neusüß5.   

Abstract

Capillary zone electrophoresis (CZE) is a powerful tool that is progressively being applied for the separation of monoclonal antibody (mAb) charge variants. Mass spectrometry (MS) is the desired detection method concerning identification of mAb variants. In biopharmaceutical applications, there exist optimized and validated electrolyte systems for mAb variant quantification. However, these electrolytes interfere greatly with the electrospray ionization (ESI) process. Here, a heart-cut CZE-CZE-MS setup with an implemented mechanical four-port valve interface was developed that used a generic ε-aminocaproic acid based background electrolyte in the first dimension and acetic acid in the second dimension. Interference-free, highly precise mass data (deviation less than 1 Da) of charge variants of trastuzumab, acting as model mAb system, were achieved. The mass accuracy obtained (low parts per million range) is discussed regarding both measured and calculated masses. Deamidation was detected for the intact model antibody, and related mass differences were significantly confirmed on the deglycosylated level. The CZE-CZE-MS setup is expected to be applicable to a variety of antibodies and electrolyte systems. Thus, it has the potential to become a compelling tool for MS characterization of antibody variants separated in ESI-interfering electrolytes. Graphical Abstract Two-dimensional capillary zone electrophoresis mass spectrometry for the characterization of intact monoclonal antibody (mAb) charge variants. A generic, but highly electrospray-interfering electrolyte system was used as first dimension for mAb charge variant separation and coupled to a volatile electrolyte system as second dimension via a four-port nanoliter valve. In this way, interference-free and precise mass spectrometric data of separated mAb charge variants, including deamidation products, were obtained.

Entities:  

Keywords:  Antibody analysis; Capillary zone electrophoresis–mass spectrometry; Electrospray ionization; Mechanical valve; Pharmaceutical application; Two-dimensional interface; ε-Aminocaproic acid

Mesh:

Substances:

Year:  2017        PMID: 28801824     DOI: 10.1007/s00216-017-0542-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  9 in total

Review 1.  Recent trends of capillary electrophoresis-mass spectrometry in proteomics research.

Authors:  Fabio P Gomes; John R Yates
Journal:  Mass Spectrom Rev       Date:  2019-08-12       Impact factor: 10.946

Review 2.  Characterizing Endogenous Protein Complexes with Biological Mass Spectrometry.

Authors:  Rivkah Rogawski; Michal Sharon
Journal:  Chem Rev       Date:  2021-08-18       Impact factor: 72.087

Review 3.  Mass Spectrometry Approaches to Glycomic and Glycoproteomic Analyses.

Authors:  L Renee Ruhaak; Gege Xu; Qiongyu Li; Elisha Goonatilleke; Carlito B Lebrilla
Journal:  Chem Rev       Date:  2018-03-19       Impact factor: 60.622

4.  Unambiguous Sequence Characterization of a Monoclonal Antibody in a Single Analysis Using a Nonspecific Immobilized Enzyme Reactor.

Authors:  Joshua D Hinkle; Robert A D'Ippolito; Maria C Panepinto; Wei-Han Wang; Dina L Bai; Jeffrey Shabanowitz; Donald F Hunt
Journal:  Anal Chem       Date:  2019-10-16       Impact factor: 6.986

5.  Separation and Characterization of Endogenous Nucleosomes by Native Capillary Zone Electrophoresis-Top-Down Mass Spectrometry.

Authors:  Kevin Jooß; Luis F Schachner; Rachel Watson; Zachary B Gillespie; Sarah A Howard; Marcus A Cheek; Matthew J Meiners; Amin Sobh; Jonathan D Licht; Michael-Christopher Keogh; Neil L Kelleher
Journal:  Anal Chem       Date:  2021-03-22       Impact factor: 6.986

6.  Investigating native capillary zone electrophoresis-mass spectrometry on a high-end quadrupole-time-of-flight mass spectrometer for the characterization of monoclonal antibodies.

Authors:  Xiaojing Shen; Zhijie Liang; Tian Xu; Zhichang Yang; Qianjie Wang; Daoyang Chen; Lucynda Pham; Wenjun Du; Liangliang Sun
Journal:  Int J Mass Spectrom       Date:  2021-01-30       Impact factor: 1.986

7.  Capillary Electrophoresis: Trends and Recent Advances.

Authors:  Robert L C Voeten; Iro K Ventouri; Rob Haselberg; Govert W Somsen
Journal:  Anal Chem       Date:  2018-01-18       Impact factor: 6.986

8.  Characterisation of a new online nanoLC-CZE-MS platform and application for the glycosylation profiling of alpha-1-acid glycoprotein.

Authors:  Alexander Stolz; Christian Neusüß
Journal:  Anal Bioanal Chem       Date:  2021-12-09       Impact factor: 4.142

9.  Application of affinity capillary electrophoresis for charge heterogeneity profiling of biopharmaceuticals.

Authors:  Andrei Hutanu; Steffen Kiessig; Andrea Bathke; Rolf Ketterer; Sonja Riner; Jan Olaf Stracke; Markus Wild; Bernd Moritz
Journal:  Electrophoresis       Date:  2019-10-08       Impact factor: 3.535

  9 in total