Literature DB >> 31584792

Unambiguous Sequence Characterization of a Monoclonal Antibody in a Single Analysis Using a Nonspecific Immobilized Enzyme Reactor.

Joshua D Hinkle1, Robert A D'Ippolito1, Maria C Panepinto1, Wei-Han Wang1, Dina L Bai1, Jeffrey Shabanowitz1, Donald F Hunt1,2.   

Abstract

Accurate sequence characterization is essential for the development of therapeutic antibodies by the pharmaceutical industry. Presented here is a methodology to obtain comprehensive sequence analysis of a monoclonal antibody. An enzyme reactor of immobilized Aspergillopepsin I, a highly stable nonspecific protease, was used to cleave reduced antibody subunits into a peptide profile ranging from 1 to 20 kDa. Utilizing the Thermo Orbitrap Fusion's unique instrument architecture combined with state-of-the-art instrument control software allowed for dynamic instrument methods that optimally characterize eluting peptides based on their size and charge density. Using a data-dependent instrument method, both collisional dissociation and electron transfer dissociation were used to fragment the appropriate charge state of analyte peptides. The instrument layout also allowed for scans to be taken in parallel using both the ion trap and Orbitrap concurrently, thus allowing larger peptides to be analyzed in high resolution using the Orbitrap while simultaneously analyzing tryptic-like peptides using the ion trap. We harnessed these capabilities to develop a custom method to optimally fragment the eluting peptides based on their mass and charge density. Using this approach, we obtained 100% sequence coverage of the total antibody in a single chromatographic analysis, enabling unambiguous sequence assignment of all residues.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31584792      PMCID: PMC8092443          DOI: 10.1021/acs.analchem.9b02666

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  51 in total

1.  A two-dimensional quadrupole ion trap mass spectrometer.

Authors:  Jae C Schwartz; Michael W Senko; John E P Syka
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

Review 2.  Chromatographic, Electrophoretic, and Mass Spectrometric Methods for the Analytical Characterization of Protein Biopharmaceuticals.

Authors:  Szabolcs Fekete; Davy Guillarme; Pat Sandra; Koen Sandra
Journal:  Anal Chem       Date:  2015-12-16       Impact factor: 6.986

Review 3.  Fcgamma receptors as regulators of immune responses.

Authors:  Falk Nimmerjahn; Jeffrey V Ravetch
Journal:  Nat Rev Immunol       Date:  2008-01       Impact factor: 53.106

4.  Determination of the pore size distribution of high-performance liquid chromatography stationary phases via inverse size exclusion chromatography.

Authors:  Ivett Bacskay; Annamária Sepsey; Attila Felinger
Journal:  J Chromatogr A       Date:  2014-03-12       Impact factor: 4.759

Review 5.  Mass Spectrometry Applied to Bottom-Up Proteomics: Entering the High-Throughput Era for Hypothesis Testing.

Authors:  Ludovic C Gillet; Alexander Leitner; Ruedi Aebersold
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2016-03-30       Impact factor: 10.745

6.  Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS.

Authors:  Lidong He; Lissa C Anderson; David R Barnidge; David L Murray; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2017-02-28       Impact factor: 3.109

Review 7.  Top-down mass spectrometry: recent developments, applications and perspectives.

Authors:  Weidong Cui; Henry W Rohrs; Michael L Gross
Journal:  Analyst       Date:  2011-08-08       Impact factor: 4.616

8.  Pentamerization of single-domain antibodies from phage libraries: a novel strategy for the rapid generation of high-avidity antibody reagents.

Authors:  Jianbing Zhang; Jamshid Tanha; Tomoko Hirama; Nam Huan Khieu; Rebecca To; Hong Tong-Sevinc; Emily Stone; Jean Robert Brisson; C Roger MacKenzie
Journal:  J Mol Biol       Date:  2004-01-02       Impact factor: 5.469

9.  Accelerated tryptic digestion for the analysis of biopharmaceutical monoclonal antibodies in plasma by liquid chromatography with tandem mass spectrometric detection.

Authors:  Antoine Lesur; Emmanuel Varesio; Gérard Hopfgartner
Journal:  J Chromatogr A       Date:  2009-11-10       Impact factor: 4.759

Review 10.  Ion Activation Methods for Peptides and Proteins.

Authors:  Jennifer S Brodbelt
Journal:  Anal Chem       Date:  2015-12-11       Impact factor: 6.986

View more
  2 in total

1.  Sequencing a Bispecific Antibody by Controlling Chain Concentration Effects When Using an Immobilized Nonspecific Protease.

Authors:  Robert A D'Ippolito; Maria C Panepinto; Keira E Mahoney; Dina L Bai; Jeffrey Shabanowitz; Donald F Hunt
Journal:  Anal Chem       Date:  2020-07-13       Impact factor: 6.986

Review 2.  Process- and Product-Related Foulants in Virus Filtration.

Authors:  Solomon Isu; Xianghong Qian; Andrew L Zydney; S Ranil Wickramasinghe
Journal:  Bioengineering (Basel)       Date:  2022-04-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.