Literature DB >> 28798838

Simultaneous measurement of erythrocyte deformability and blood viscoelasticity using micropillars and co-flowing streams under pulsatile blood flows.

Yang Jun Kang1.   

Abstract

The biophysical properties of blood provide useful information on the variation in hematological disorders or diseases. In this study, a simultaneous measurement method of RBC (Red Blood Cell) deformability and blood viscoelasticity is proposed by evaluating hemodynamic variations through micropillars and co-flowing streams under sinusoidal blood flow. A disposable microfluidic device is composed of two inlets and two outlets, two upper side channels, and two lower side channels connected to one bridge channel. First, to measure the RBC deformability, the left-lower side channel has a deformability assessment chamber (DAC) with narrow-sized micropillars. Second, to evaluate the blood viscoelasticity in co-flowing streams, a phosphate buffered saline solution is supplied at a constant flow rate. By closing or opening a pinch valve connected to the outlet of DAC, blood flows in forward or back-and-forth mode. A time-resolved micro-particle image velocimetry technique and a digital image processing technique are used to quantify the blood velocity and image intensity. Then, RBC deformability is evaluated by quantifying the blood volume passing through the DAC under forward flow, and quantifying the variations of blood velocity and image intensity in the DAC under back-and-forth flow. Using a discrete circuit model, blood viscoelasticity is obtained by evaluating variations of blood velocity and co-flowing streams. The effect of several factors (period, hematocrit, and base solution) on the performance is quantitatively evaluated. Based on the experimental results, the period of sinusoidal flow and hematocrit are fixed at 30 s and 50%, respectively. As a performance demonstration, the proposed method is employed to detect the homogeneous and heterogeneous blood composed of normal RBCs and hardened RBCs. These experimental results show that the RBC deformability is more effective to detect minor subpopulations of heterogeneous bloods, compared with blood viscoelasticity. Therefore, it leads to the conclusion that the proposed method has the ability to evaluate RBC deformability and blood viscoelasticity under sinusoidal blood flow, with sufficient accuracy and high-throughput.

Entities:  

Year:  2017        PMID: 28798838      PMCID: PMC5533506          DOI: 10.1063/1.4973863

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  26 in total

1.  Sorting cells by size, shape and deformability.

Authors:  Jason P Beech; Stefan H Holm; Karl Adolfsson; Jonas O Tegenfeldt
Journal:  Lab Chip       Date:  2012-02-10       Impact factor: 6.799

2.  Microfluidic micropipette aspiration for measuring the deformability of single cells.

Authors:  Quan Guo; Sunyoung Park; Hongshen Ma
Journal:  Lab Chip       Date:  2012-05-23       Impact factor: 6.799

3.  Microfluidics-based assessment of cell deformability.

Authors:  Andrea Adamo; Armon Sharei; Luigi Adamo; ByungKun Lee; Shirley Mao; Klavs F Jensen
Journal:  Anal Chem       Date:  2012-07-10       Impact factor: 6.986

4.  Microfluidics analysis of red blood cell membrane viscoelasticity.

Authors:  Giovanna Tomaiuolo; Mario Barra; Valentina Preziosi; Antonio Cassinese; Bruno Rotoli; Stefano Guido
Journal:  Lab Chip       Date:  2010-11-15       Impact factor: 6.799

5.  Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel.

Authors:  Yang Jun Kang; Jeongeun Ryu; Sang-Joon Lee
Journal:  Biomicrofluidics       Date:  2013-07-26       Impact factor: 2.800

Review 6.  Red cell deformability and its relevance to blood flow.

Authors:  S Chien
Journal:  Annu Rev Physiol       Date:  1987       Impact factor: 19.318

7.  Passive circulating cell sorting by deformability using a microfluidic gradual filter.

Authors:  P Preira; V Grandné; J-M Forel; S Gabriele; M Camara; O Theodoly
Journal:  Lab Chip       Date:  2012-11-12       Impact factor: 6.799

8.  A microfabricated deformability-based flow cytometer with application to malaria.

Authors:  Hansen Bow; Igor V Pivkin; Monica Diez-Silva; Stephen J Goldfless; Ming Dao; Jacquin C Niles; Subra Suresh; Jongyoon Han
Journal:  Lab Chip       Date:  2011-02-03       Impact factor: 6.799

9.  Red Blood Cells from Individuals with Abdominal Obesity or Metabolic Abnormalities Exhibit Less Deformability upon Entering a Constriction.

Authors:  Nancy F Zeng; Jordan E Mancuso; Angela M Zivkovic; Jennifer T Smilowitz; William D Ristenpart
Journal:  PLoS One       Date:  2016-06-03       Impact factor: 3.240

10.  Assessment of red blood cell deformability in type 2 diabetes mellitus and diabetic retinopathy by dual optical tweezers stretching technique.

Authors:  Rupesh Agrawal; Thomas Smart; João Nobre-Cardoso; Christopher Richards; Rhythm Bhatnagar; Adnan Tufail; David Shima; Phil H Jones; Carlos Pavesio
Journal:  Sci Rep       Date:  2016-03-15       Impact factor: 4.379

View more
  5 in total

1.  Comparing of Frequency Shift and Impedance Analysis Method Based on QCM Sensor for Measuring the Blood Viscosity.

Authors:  Shuang Liao; Peng Ye; Cheng Chen; Jie Zhang; Lin Xu; Feng Tan
Journal:  Sensors (Basel)       Date:  2022-05-17       Impact factor: 3.847

2.  Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations.

Authors:  Yang Jun Kang
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

3.  A Disposable Blood-on-a-Chip for Simultaneous Measurement of Multiple Biophysical Properties.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2018-09-20       Impact factor: 2.891

4.  Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2019-08-30       Impact factor: 2.891

5.  Experimental Investigation of Air Compliance Effect on Measurement of Mechanical Properties of Blood Sample Flowing in Microfluidic Channels.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2020-04-28       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.