Validity of the Digital Inclinometer and iPhone When Measuring Thoracic Spine Rotation.

Jonathan Bucke1, Simon Spencer1, Louise Fawcett1, Lawrence Sonvico1, Alison Rushton2, Nicola R Heneghan2.   

Abstract

CONTEXT: Spinal axial rotation is required for many functional and sporting activities. Eighty percent of axial rotation occurs in the thoracic spine. Existing measures of thoracic spine rotation commonly involve laboratory equipment, use a seated position, and include lumbar motion. A simple performance-based outcome measure would allow clinicians to evaluate isolated thoracic spine rotation. Currently, no valid measure exists.
OBJECTIVE: To explore the criterion and concurrent validity of a digital inclinometer (DI) and iPhone Clinometer app (iPhone) for measuring thoracic spine rotation using the heel-sit position.
DESIGN: Controlled laboratory study.
SETTING: University laboratory. PATIENTS OR OTHER PARTICIPANTS: A total of 23 asymptomatic healthy participants (14 men, 9 women; age = 25.82 ± 4.28 years, height = 170.26 ± 8.01 cm, mass = 67.50 ± 9.46 kg, body mass index = 23.26 ± 2.79) were recruited from a student population. MAIN OUTCOME MEASURE(S): We took DI and iPhone measurements of thoracic spine rotation in the heel-sit position concurrently with dual-motion analysis (laboratory measure) and ultrasound imaging of the underlying bony tissue motion (reference standard). To determine the criterion and concurrent validity, we used the Pearson product moment correlation coefficient (r, 2 tailed) and Bland-Altman plots.
RESULTS: The DI (r = 0.88, P < .001) and iPhone (r = 0.88, P < .001) demonstrated strong criterion validity. Both also had strong concurrent validity (r = 0.98, P < .001). Bland-Altman plots illustrated mean differences of 5.82° (95% confidence interval [CI] = 20.37°, -8.73°) and 4.94° (95% CI = 19.23°, -9.35°) between the DI and iPhone, respectively, and the reference standard and 0.87° (95% CI = 6.79°, -5.05°) between the DI and iPhone.
CONCLUSIONS: The DI and iPhone provided valid measures of thoracic spine rotation in the heel-sit position. Both can be used in clinical practice to assess thoracic spine rotation, which may be valuable when evaluating thoracic dysfunction.

Entities:  

Keywords:  criterion validity; reference standard; thoracic spine mobility

Mesh:

Year:  2017        PMID: 28787176      PMCID: PMC5634230          DOI: 10.4085/1062-6050-52.6.05

Source DB:  PubMed          Journal:  J Athl Train        ISSN: 1062-6050            Impact factor:   2.860


  17 in total

1.  The Modified-Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: a study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change.

Authors:  M Tousignant; L Poulin; S Marchand; A Viau; C Place
Journal:  Disabil Rehabil       Date:  2005-05-20       Impact factor: 3.033

2.  Thoracic rotation measurement techniques: clinical commentary.

Authors:  Katherine D Johnson; Terry L Grindstaff
Journal:  N Am J Sports Phys Ther       Date:  2010-12

3.  Soft tissue artefact in the thoracic spine during axial rotation and arm elevation using ultrasound imaging: a descriptive study.

Authors:  Nicola R Heneghan; George M Balanos
Journal:  Man Ther       Date:  2010-12

4.  The reliability and concurrent validity of measurements used to quantify lumbar spine mobility: an analysis of an iphone® application and gravity based inclinometry.

Authors:  Morey J Kolber; Matias Pizzini; Ashley Robinson; Dania Yanez; William J Hanney
Journal:  Int J Sports Phys Ther       Date:  2013-04

Review 5.  A regional interdependence model of musculoskeletal dysfunction: research, mechanisms, and clinical implications.

Authors:  Derrick G Sueki; Joshua A Cleland; Robert S Wainner
Journal:  J Man Manip Ther       Date:  2013-05

6.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity.

Authors:  R L Gajdosik; R W Bohannon
Journal:  Phys Ther       Date:  1987-12

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults.

Authors:  Michel Tousignant; Cécil Smeesters; Anne-Marie Breton; Emilie Breton; Hélène Corriveau
Journal:  J Orthop Sports Phys Ther       Date:  2006-04       Impact factor: 4.751

9.  Clinical and radiological investigation of thoracic spine extension motion during bilateral arm elevation.

Authors:  Stephen J Edmondston; Andrij Ferguson; Patrick Ippersiel; Lars Ronningen; Stig Sodeland; Luke Barclay
Journal:  J Orthop Sports Phys Ther       Date:  2012-04-20       Impact factor: 4.751

10.  The effect of shoulder movements on thoracic spine 3D motion.

Authors:  D Theodoridis; S Ruston
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-06       Impact factor: 2.063

View more
  6 in total

Review 1.  Thoracic dysfunction in whiplash associated disorders: A systematic review.

Authors:  Nicola R Heneghan; Richard Smith; Isaak Tyros; Deborah Falla; Alison Rushton
Journal:  PLoS One       Date:  2018-03-23       Impact factor: 3.240

2.  What is the effect of prolonged sitting and physical activity on thoracic spine mobility? An observational study of young adults in a UK university setting.

Authors:  Nicola R Heneghan; Gemma Baker; Kimberley Thomas; Deborah Falla; Alison Rushton
Journal:  BMJ Open       Date:  2018-05-05       Impact factor: 2.692

3.  Clinical reasoning framework for thoracic spine exercise prescription in sport: a systematic review and narrative synthesis.

Authors:  Nicola R Heneghan; Svein M Lokhaug; Isaak Tyros; Sigurd Longvastøl; Alison Rushton
Journal:  BMJ Open Sport Exerc Med       Date:  2020-03-29

4.  Effects of Instrument-Assisted Soft-Tissue Mobilization on Ankle Range of Motion and Triceps Surae Pressure Pain Sensitivity.

Authors:  Corrie Myburgh; Are Hammern; Peter Mannfjord; Eleanor Boyle
Journal:  J Rehabil Med Clin Commun       Date:  2018-09-20

Review 5.  Analysis of the Active Measurement Systems of the Thoracic Range of Movements of the Spine: A Systematic Review and a Meta-Analysis.

Authors:  Pablo Esteban-González; Eleuterio A Sánchez-Romero; Jorge Hugo Villafañe
Journal:  Sensors (Basel)       Date:  2022-04-15       Impact factor: 3.847

6.  Test-Retest Reliability of an iPhone® Inclinometer Application to Assess the Lumbar Joint Repositioning Error in Non-Specific Chronic Low Back Pain.

Authors:  Alejandro Caña-Pino; Luís Espejo-Antúnez; José Carmelo Adsuar; María Dolores Apolo-Arenas
Journal:  Int J Environ Res Public Health       Date:  2021-03-03       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.