Literature DB >> 20621544

Soft tissue artefact in the thoracic spine during axial rotation and arm elevation using ultrasound imaging: a descriptive study.

Nicola R Heneghan1, George M Balanos.   

Abstract

Much of the current understanding of thoracic motion analysis is based on the use of skin sensors or markers. Skin tissue artefact, movement occurring between the skin and underlying bone, is readily acknowledged by researchers as a source or measurement error, yet to date has not been quantified. The aim of this study was therefore to evaluate skin tissue artefact, during thoracic axial rotation and single arm elevation. Using an ultrasound imaging technique this study describes soft tissue artefact in the thoracic spine during axial rotation and single arm elevation in sitting using 30 asymptomatic individuals. The findings from this study indicate that soft tissue artefact (STA) in the mid thoracic region ranges between 14 and 16 mm for 35-degrees of rotation. During single arm elevation 0.8-1.5 mm STA was measured at the levels of T1-T6-T12. The results of this study suggests that STA is a considerable and variable source of error in all regions of the thoracic spine, but most notably for the mid thoracic region during axial rotation.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20621544     DOI: 10.1016/j.math.2010.05.004

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  4 in total

1.  Validity of the Digital Inclinometer and iPhone When Measuring Thoracic Spine Rotation.

Authors:  Jonathan Bucke; Simon Spencer; Louise Fawcett; Lawrence Sonvico; Alison Rushton; Nicola R Heneghan
Journal:  J Athl Train       Date:  2017-08-08       Impact factor: 2.860

Review 2.  Application of Ultrasound in Spine Kinematic Determination: A Systemic Review.

Authors:  Mohammad Reza Effatparvar; Stéphane Sobczak
Journal:  J Med Ultrasound       Date:  2022-02-24

Review 3.  Analysis of the Active Measurement Systems of the Thoracic Range of Movements of the Spine: A Systematic Review and a Meta-Analysis.

Authors:  Pablo Esteban-González; Eleuterio A Sánchez-Romero; Jorge Hugo Villafañe
Journal:  Sensors (Basel)       Date:  2022-04-15       Impact factor: 3.847

4.  Soft tissue artefacts of the human back: comparison of the sagittal curvature of the spine measured using skin markers and an open upright MRI.

Authors:  Roland Zemp; Renate List; Turgut Gülay; Jean Pierre Elsig; Jaroslav Naxera; William R Taylor; Silvio Lorenzetti
Journal:  PLoS One       Date:  2014-04-18       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.