| Literature DB >> 28785691 |
Muneo Kurokawa1,2, Shiro Uemura2,3, Makoto Watanabe2, Yoko Dote2, Yu Sugawara2, Yutaka Goryo2, Tomoya Ueda2, Satoshi Okayama2, Michinori Kayashima1, Yoshihiko Saito2.
Abstract
OBJECTIVE: In optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI), stent size is usually determined according to the pre-PCI lumen size of either the distal or proximal reference site. However, the effect of the OCT imaging catheter crossing the target lesion on the reference lumen measurements has not been studied. We evaluated changes in the reference lumen size before and after PCI using frequency domain OCT.Entities:
Keywords: Coronary artery disease; Optical coherence tomography; Percutaneous coronary intervention
Year: 2015 PMID: 28785691 PMCID: PMC5497265 DOI: 10.1016/j.ijcha.2015.06.003
Source DB: PubMed Journal: Int J Cardiol Heart Vasc ISSN: 2352-9067
Fig. 1Schematic methods for OCT measurement of target lesion.
Patient characteristics.
| N = 100 | |
|---|---|
| Age, years (± SD) | 67 ± 12 |
| Male gender | 81 |
| Coronary risk factor | |
| Hypertension | 49 |
| Dyslipidemia | 64 |
| Diabetes mellitus | 39 |
| Current smoker | 48 |
| Target imaging vessel | |
| LAD (left anterior descending coronary artery) | 36 |
| LCX (left circumflex coronary artery) | 38 |
| RCA (right coronary artery) | 26 |
| QCA | |
| Lesion length, mm | 17.2 ± 6.20 |
| MLD, mm | 1.20 ± 0.34 |
| Distal reference site, mm | 2.63 ± 0.55 |
| Proximal reference site, mm | 3.16 ± 0.43 |
| AHA lesion classification | |
| A | 3 |
| B1 | 41 |
| B2 | 23 |
| C | 33 |
OCT measurements.
| Pre-PCI (n = 100) | Post-PCI (n = 100) | Post–Pre | P value | |
|---|---|---|---|---|
| MLA site | LA, mm2 1.27 ± 0.62 | |||
| LD, mm 1.27 ± 0.27 | ||||
| Distal reference site | ||||
| LA, mm25.20 ± 2.66 | 5.41 ± 2.54 | 0.21 ± 0.74 | 0.003 | |
| LD, mm 2.57 ± 0.60 | 2.62 ± 0.64 | 0.05 ± 0.18 | < 0.001 | |
| Proximal reference site | ||||
| LA, mm2 7.99 ± 3.95 | 7.68 ± 3.90 | − 0.31 ± 0.74 | < 0.001 | |
| LD, mm 3.19 ± 0.73 | 3.12 ± 0.73 | − 0.07 ± 0.13 | < 0.001 |
Fig. 2(A) Receiver operating characteristic curve analysis for MLA at target stenosis in predicting the increase in distal reference site after PCI. The AUC for MLA was 0.78 (P < 0.001). When the MLA cut-off value was set at 1.50 mm2, the sensitivity and specificity were 0.69 and 84%, respectively. (B) A representative case of MLA < 1.5 mm2. The imaging catheter occupies more than 60% of the cross-sectional lumen area.
Changes in OCT measurements according to the cut-off MLA value of 1.50 mm2.
| (MLA < 1.50 mm2, n = 68) (MLA ≥ 1.50 mm2, n = 32) | Pre PCI | Post PCI | Post–Pre | P value |
|---|---|---|---|---|
| MLA < 1.50 mm2 | ||||
| LA, mm2 | 4.39 ± 1.79 | 4.78 ± 1.86 | 0.39 ± 0.66 | < 0.001 |
| LD, mm | 2.28 ± 0.48 | 2.40 ± 0.47 | 0.12 ± 0.17 | < 0.001 |
| MLA ≥ 1.50 mm2 | ||||
| LA, mm2 | 7.21 ± 2.97 | 7.10 ± 2.94 | − 0.11 ± 0.76 | 0.41 |
| LD, mm | 2.96 ± 0.68 | 2.94 ± 0.65 | − 0.02 ± 0.18 | 0.53 |
| MLA < 1.50 mm2 | ||||
| LA, mm2 | 7.38 ± 3.04 | 7.08 ± 3.12 | − 0.30 ± 0.75 | < 0.001 |
| LD, mm | 3.00 ± 0.62 | 2.94 ± 0.62 | − 0.06 ± 0.14 | < 0.001 |
| MLA ≥ 1.50 mm2 | ||||
| LA, mm2 | 9.85 ± 4.87 | 9.53 ± 4.88 | − 0.32 ± 0.48 | < 0.001 |
| LD, mm | 3.45 ± 0.81 | 3.39 ± 0.81 | − 0.06 ± 0.10 | < 0.001 |
Fig. 3Changes in the lumen diameter at distal (A) and proximal (B) reference site of target lesion. Each reference is categorized according to 1.50 mm2 value of MLA site of target lesion.
Fig. 4OCT tissue characteristics at distal (A) and proximal (B) reference site of target lesion. There were no differences in the distribution of tissue characteristics according to the changes in lumen diameter of pre- and post-PCI.