Literature DB >> 24530675

Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.

Guilherme F Attizzani1, Davide Capodanno2, Yohei Ohno3, Corrado Tamburino4.   

Abstract

Incomplete stent apposition (ISA) is characterized by the lack of contact of at least 1 stent strut with the vessel wall in a segment not overlying a side branch; it is more commonly found in drug-eluting stents than bare-metal stents. The accurate diagnosis of ISA, initially only possible with intravascular ultrasound, can currently be performed with higher accuracy by optical coherence tomography, which also enables strut-level assessment due to its higher axial resolution. Different circumstances related both to the index procedure and to vascular healing might influence ISA occurrence. Although several histopathology and clinical studies linked ISA to stent thrombosis, potential selection bias precluded definitive conclusions. Initial studies usually performed single time point assessments comparing overall ISA percentage and magnitude in different groups (i.e., stent type), thus hampering a comprehensive understanding of its relationship with vascular healing. Serial intravascular imaging studies that evaluated vascular response heterogeneity recently helped fill this gap. Some particular clinical scenarios such as acute coronary syndromes, bifurcations, tapered vessels, overlapping stents, and chronic total occlusions might predispose to ISA. Interventional cardiologists should be committed to optimal stent choices and techniques of implantation and use intravascular imaging guidance when appropriate to aim at minimizing acute ISA. In addition, the active search for new stent platforms that could accommodate vessel remodeling over time (i.e., self-expandable stents) and for new polymers and/or eluting drugs that could induce less inflammation (hence, less positive remodeling) could ultimately reduce the occurrence of ISA and its potentially harmful consequences.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  drug-eluting stent(s); incomplete stent apposition; intravascular ultrasound; optical coherence tomography; percutaneous coronary intervention; stent malapposition

Mesh:

Substances:

Year:  2014        PMID: 24530675     DOI: 10.1016/j.jacc.2014.01.019

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  29 in total

1.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

2.  An assessment of the quality of optical coherence tomography image acquisition.

Authors:  Elder Iarossi Zago; Abdul Jawwad Samdani; Gabriel Tensol Rodrigues Pereira; Armando Vergara-Martel; Mohamad Amer Alaiti; Luis Augusto Dallan; Patricia Ely Pizzato; Vladislav Zimin; Anas Fares; Hiram G Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2020-02-18       Impact factor: 2.357

3.  Neointimal coverage and late apposition of everolimus-eluting bioresorbable scaffolds implanted in the acute phase of myocardial infarction: OCT data from the PRAGUE-19 study.

Authors:  Petr Toušek; Viktor Kočka; Martin Malý; Libor Lisa; Tomáš Buděšínský; Petr Widimský
Journal:  Heart Vessels       Date:  2015-04-21       Impact factor: 2.037

Review 4.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

5.  The impact of three-dimensional optical coherence tomography and kissing-balloon inflation for stent implantation to bifurcation lesions.

Authors:  Hiroshi Koiwaya; Masao Takemoto; Kenji Ogata; Tatsuya Nakama; Makoto Furugen; Nozomi Watanabe; Nehiro Kuriyama; Yoshisato Shibata
Journal:  J Cardiol Cases       Date:  2016-01-16

Review 6.  Optical coherence tomography-guided percutaneous coronary intervention: a review of current clinical applications.

Authors:  Kazumasa Kurogi; Masanobu Ishii; Nobuyasu Yamamoto; Kenshi Yamanaga; Kenichi Tsujita
Journal:  Cardiovasc Interv Ther       Date:  2021-01-17

Review 7.  Management of Percutaneous Coronary Intervention Complications.

Authors:  Gregory Means; Christopher End; Prashant Kaul
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-04

8.  Coronary stent thrombosis: what have we learned?

Authors:  Carlos Collet; Yohei Sotomi; Rafael Cavalcante; Pannipa Suwannasom; Erhan Tenekecioglu; Yoshinobu Onuma; Patrick W Serruys
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

Review 9.  A Practical Approach to Assessing Stent Results with IVUS or OCT.

Authors:  Daisuke Hachinohe; Satoru Mitomo; Luciano Candilio; Azeem Latib
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jan-Mar

10.  Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.

Authors:  Fumiaki Nakao; Takayuki Okamura; Takeshi Suetomi; Jutaro Yamada; Takeshi Nakamura; Tooru Ueda; Takamasa Oda; Masashi Kanemoto; Yasuhiro Ikeda; Takashi Fujii; Masafumi Yano
Journal:  Heart Vessels       Date:  2016-02-15       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.