Literature DB >> 28769506

PNEUMATIC RETINOPEXY IN RHEGMATOGENOUS RETINAL DETACHMENT.

R P Gupta1, M Deshpande2, A Bharadwaj3, V K Baranwal4.   

Abstract

Existing surgical modes for retinal detachment are elaborate and extremely complex. We have treated 20 cases of rhegmatogenous retinal detachment with pneumatic retinopexy which is Iess time consuming and does not require hospitalization. After pneumatic retinopexy reattachment of retina was achieved in 15 (75%) eyes. In 2 eyes retinal reattachment was achieved after repeating intravitreal injection of sulphur hexafluoride gas. Remaining 3 eyes were secondarily treated with scleral buckle surgery. One case needed vitreoretinal surgery. In pneumatic retinopexy there is minimum tissue handling and functional results are good.

Entities:  

Keywords:  Retinal detachment; Sulphur hexafluoride; Vitreo retinopathy

Year:  2017        PMID: 28769506      PMCID: PMC5531145          DOI: 10.1016/S0377-1237(17)30747-5

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  7 in total

1.  Pneumatic retinopexy. A multicenter randomized controlled clinical trial comparing pneumatic retinopexy with scleral buckling. The Retinal Detachment Study Group.

Authors:  P E Tornambe; G F Hilton
Journal:  Ophthalmology       Date:  1989-06       Impact factor: 12.079

Review 2.  Pneumatic retinopexy: principles and practice.

Authors:  G F Hilton; T Das; A B Majji; S Jalali
Journal:  Indian J Ophthalmol       Date:  1996-09       Impact factor: 1.848

3.  Expanded indications for pneumatic retinopexy.

Authors:  P E Tornambe; G F Hilton; N F Kelly; T C Salzano; J W Wells; R T Wendel
Journal:  Ophthalmology       Date:  1988-05       Impact factor: 12.079

4.  Comparison of pneumatic retinopexy with alternative surgical techniques.

Authors:  I L McAllister; S M Meyers; H Zegarra; F A Gutman; Z N Zakov; G J Beck
Journal:  Ophthalmology       Date:  1988-07       Impact factor: 12.079

5.  The management of subretinal gas following attempted pneumatic retinal reattachment.

Authors:  H R McDonald; G W Abrams; A R Irvine; J O Sipperley; B S Boyden; J V Fiore; H Zegarra
Journal:  Ophthalmology       Date:  1987-04       Impact factor: 12.079

6.  Pneumatic retinopexy. A collaborative report of the first 100 cases.

Authors:  G F Hilton; N E Kelly; T C Salzano; P E Tornambe; J W Wells; R T Wendel
Journal:  Ophthalmology       Date:  1987-04       Impact factor: 12.079

7.  Pneumatic retinopexy. A two-step outpatient operation without conjunctival incision.

Authors:  G F Hilton; W S Grizzard
Journal:  Ophthalmology       Date:  1986-05       Impact factor: 12.079

  7 in total
  1 in total

1.  Pneumoretinopexy versus scleral buckling in retinal detachments with superior breaks: A comparative analysis of outcome and cost.

Authors:  Arshi Singh; Umesh Chandra Behera
Journal:  Indian J Ophthalmol       Date:  2021-02       Impact factor: 1.848

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.