Jan Bredow1,2, C Meyer3, F Siedek4, W F Neiss5, L Löhrer6, L P Müller3, P Eysel3, G Stein3. 1. Center for Spinal Surgery, Schön Klinik Düsseldorf, Schön Klinik Düsseldorf SE & Co. KG, Am Heerdter Krankenhaus 2, 40549, Düsseldorf, Germany. JBredow@schoen-kliniken.de. 2. Department of Orthopaedics and Trauma Surgery, University Hospital of Cologne, Cologne, Germany. JBredow@schoen-kliniken.de. 3. Department of Orthopaedics and Trauma Surgery, University Hospital of Cologne, Cologne, Germany. 4. Department of Radiology, University Hospital of Cologne, Cologne, Germany. 5. Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany. 6. Center for Spinal Surgery, Schön Klinik Düsseldorf, Schön Klinik Düsseldorf SE & Co. KG, Am Heerdter Krankenhaus 2, 40549, Düsseldorf, Germany.
Abstract
INTRODUCTION: Pedicle screw stabilization, the standard technique in the thoracic and lumbar spine, is increasingly used in the cervical spine. Initial studies on the use of anterior pedicle screws (ATPS) in the cervical spine have been recently published. ATPS use has theoretical advantages over posterior stabilization. We have already established a 3D-fluoroscopy navigation setup in a study of artificial bones. The aim of the current study was to evaluate the positioning quality/accuracy of ATPS introduced to human specimens. METHODS: 36 cannulated screws (3.5 mm) were implanted anteriorly into the C3-C7 segments of four spines (unfixed, frozen, cadaveric specimens) using a 3D-fluoroscopy navigation system. Placement accuracy was evaluated using a recently published classification on postoperative CT scans. Grade 1 is perfect position with pedicle wall perforation <1 mm, grade 2 is perforation <2 mm, etc., and finally grade 5 is cortical perforation of >4 mm and/or transverse foramen entry. RESULTS: 36 anterior pedicle screws were inserted into four human cervical spine specimens. Of these, seven screws were introduced to C3, five to C4 and eight each to C5, C6, and C7. Classified with the modified G&R, 21 of 36 (58.3%) were grade 1. Ten screws (27.8%) were grade 2. Grade 4 was assessed for two screws and grade 5 for three. Customary "good" positioning, combining grades 1 and 2, was thus found in 86.1%. Five screws (13.9%) did not meet this criterion (grade ≥3). CONCLUSIONS: With 86.1% of good positioning (grade 2 or better), a 3D-fluoroscopy navigation of ATPS screws into human c-spine specimens achieved a satisfying results. These are at least comparable to results presented in the literature for posteriorly introduced subaxial pedicle screws.
INTRODUCTION: Pedicle screw stabilization, the standard technique in the thoracic and lumbar spine, is increasingly used in the cervical spine. Initial studies on the use of anterior pedicle screws (ATPS) in the cervical spine have been recently published. ATPS use has theoretical advantages over posterior stabilization. We have already established a 3D-fluoroscopy navigation setup in a study of artificial bones. The aim of the current study was to evaluate the positioning quality/accuracy of ATPS introduced to human specimens. METHODS: 36 cannulated screws (3.5 mm) were implanted anteriorly into the C3-C7 segments of four spines (unfixed, frozen, cadaveric specimens) using a 3D-fluoroscopy navigation system. Placement accuracy was evaluated using a recently published classification on postoperative CT scans. Grade 1 is perfect position with pedicle wall perforation <1 mm, grade 2 is perforation <2 mm, etc., and finally grade 5 is cortical perforation of >4 mm and/or transverse foramen entry. RESULTS: 36 anterior pedicle screws were inserted into four human cervical spine specimens. Of these, seven screws were introduced to C3, five to C4 and eight each to C5, C6, and C7. Classified with the modified G&R, 21 of 36 (58.3%) were grade 1. Ten screws (27.8%) were grade 2. Grade 4 was assessed for two screws and grade 5 for three. Customary "good" positioning, combining grades 1 and 2, was thus found in 86.1%. Five screws (13.9%) did not meet this criterion (grade ≥3). CONCLUSIONS: With 86.1% of good positioning (grade 2 or better), a 3D-fluoroscopy navigation of ATPS screws into human c-spine specimens achieved a satisfying results. These are at least comparable to results presented in the literature for posteriorly introduced subaxial pedicle screws.
Entities:
Keywords:
Accuracy of screw insertion; Anterior transpedicular screws; Navigated screw insertion; Spine surgery
Authors: Heiko Koller; Rene Schmidt; Michael Mayer; Wolfgang Hitzl; Juliane Zenner; Stefan Midderhoff; Stefan Middendorf; Nicolaus Graf; Nicolaus Gräf; H Resch; Hans-Joachim Wilke; Hans-Joachim Willke Journal: Eur Spine J Date: 2010-06-30 Impact factor: 3.134
Authors: Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein Journal: Eur Spine J Date: 2016-01-25 Impact factor: 3.134
Authors: Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl Journal: Eur Spine J Date: 2008-01-26 Impact factor: 3.134
Authors: Heiko Koller; Wolfgang Hitzl; Frank Acosta; Mark Tauber; Juliane Zenner; Herbert Resch; Yasutsugu Yukawa; Oliver Meier; Rene Schmidt; Michael Mayer Journal: Eur Spine J Date: 2009-07-03 Impact factor: 3.134
Authors: Sertac Kirnaz; Harry Gebhard; Taylor Wong; Raj Nangunoori; Franziska Anna Schmidt; Kosuke Sato; Roger Härtl Journal: Ann Transl Med Date: 2021-01