Literature DB >> 28750697

Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation.

Jin Iwasawa1, Jacob S Koruth1, Jan Petru2, Libor Dujka2, Stepan Kralovec2, Katerina Mzourkova2, Srinivas R Dukkipati1, Petr Neuzil2, Vivek Y Reddy3.   

Abstract

BACKGROUND: Saline irrigation improved the safety of radiofrequency (RF) ablation, but the thermal feedback for energy titration is absent.
OBJECTIVES: To allow temperature-controlled irrigated ablation, a novel irrigated RF catheter was designed with a diamond-embedded tip (for rapid cooling) and 6 surface thermocouples to reflect tissue temperature. High-resolution electrograms (EGMs) from the split-tip electrode allowed rapid lesion assessment. The authors evaluated the preclinical and clinical performance of this catheter for pulmonary vein (PV) isolation.
METHODS: Using the DiamondTemp (DT) catheter, pigs (n = 6) underwent discrete atrial ablation in a temperature control mode (60°C/50 W) until there was ∼80% EGM amplitude reduction. In a single-center clinical feasibility study, 35 patients underwent PV isolation with the DT catheter (study group); patients were planned for PV remapping after 3 months, regardless of symptomatology. A control group included 35 patients who underwent PV isolation with a standard force-sensing catheter.
RESULTS: Porcine lesion histology revealed transmurality in 51 of 55 lesions (92.7%). In patients, all PVs were successfully isolated; no char or thrombus formation was observed. Compared with the control group, the study cohort had shorter mean RF application duration (26.3 ± 5.2 min vs. 89.2 ± 27.2 min; p < 0.001), shorter mean fluoroscopic time (11.2 ± 8.5 min vs. 19.5 ± 6.8 min; p < 0.001), and lower acute dormant PV reconduction (0 of 35 vs. 5 of 35; p = 0.024). At 3 months, 23 patients underwent remapping: 39 of 46 PV pairs (84.8%) remained durably isolated in 17 of these patients (73.9%).
CONCLUSIONS: This first-in-human series demonstrated that temperature-controlled irrigated ablation produced rapid, efficient, and durable PV isolation. (ACT DiamondTemp Temperature-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation [TRAC-AF]; NCT02821351).
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  catheter ablation; electrogram; first-in-human; histology; remapping

Mesh:

Year:  2017        PMID: 28750697     DOI: 10.1016/j.jacc.2017.06.008

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

1.  [Pulmonary vein isolation using radiofrequency ablation].

Authors:  Leon Iden; Sonia Busch; Daniel Steven; Roland R Tilz; Dong-In Shin; K R Julian Chun; Heidi Estner; Felix Bourier; David Duncker; Philipp Sommer; Andreas Metzner; Tilman Maurer; Nils-Christian Ewertsen; Henning Jansen; Andreas Rillig; Victoria Johnson; Till Althoff
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-07-26

Review 2.  Innovations in atrial fibrillation ablation.

Authors:  Jitae A Kim; Khurrum Khan; Riyad Kherallah; Shamis Khan; Ishan Kamat; Owais Ulhaq; Qussay Marashly; Mihail G Chelu
Journal:  J Interv Card Electrophysiol       Date:  2022-04-11       Impact factor: 1.900

3.  Universal Method of Compatibility Assessment for Novel Ablation Technologies With Different 3D Navigation Systems.

Authors:  Luigi Pannone; Ivan Eltsov; Robbert Ramak; David Cabrita; Marc Verherstraeten; Anaïs Gauthey; Antonio Sorgente; Cinzia Monaco; Ingrid Overeinder; Gezim Bala; Alexandre Almorad; Erwin Ströker; Juan Sieira; Pedro Brugada; Mark La Meir; Gian-Battista Chierchia; Carlo de Asmundis
Journal:  Front Cardiovasc Med       Date:  2022-06-28

4.  Temperature-Controlled Catheter Ablation for Paroxysmal Atrial Fibrillation: the QDOT-MICRO Workflow Sttudy.

Authors:  Tom De Potter; Massimo Grimaldi; Henrik Kjaerulf Jensen; Josef Kautzner; Petr Neuzil; Johan Vijgen; Andrea Natale; Steen Buus Kristiansen; Peter Lukac; Petr Peichl; Vivek Y Reddy
Journal:  J Atr Fibrillation       Date:  2021-04-30

5.  A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber.

Authors:  Mario Gómez-Barea; Tomás García-Sánchez; Antoni Ivorra
Journal:  Sci Rep       Date:  2022-09-27       Impact factor: 4.996

6.  Assessing the Relationship of Applied Force and Ablation Duration on Lesion Size Using a Diamond Tip Catheter Ablation System.

Authors:  Atul Verma; Megan M Schmidt; Jean-Pierre Lalonde; David A Ramirez; Michael K Getman
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-06-17
  6 in total