Plane-dependent ML scatter scaling: 3D extension of the 2D simulated single scatter (SSS) estimate.

Ahmadreza Rezaei1, Koen Salvo, Thomas Vahle, Vladimir Panin, Michael Casey, Fernando Boada, Michel Defrise, Johan Nuyts.   

Abstract

Scatter correction is typically done using a simulation of the single scatter, which is then scaled to account for multiple scatters and other possible model mismatches. This scaling factor is determined by fitting the simulated scatter sinogram to the measured sinogram, using only counts measured along LORs that do not intersect the patient body, i.e. 'scatter-tails'. Extending previous work, we propose to scale the scatter with a plane dependent factor, which is determined as an additional unknown in the maximum likelihood (ML) reconstructions, using counts in the entire sinogram rather than only the 'scatter-tails'. The ML-scaled scatter estimates are validated using a Monte-Carlo simulation of a NEMA-like phantom, a phantom scan with typical contrast ratios of a 68Ga-PSMA scan, and 23 whole-body 18F-FDG patient scans. On average, we observe a 12.2% change in the total amount of tracer activity of the MLEM reconstructions of our whole-body patient database when the proposed ML scatter scales are used. Furthermore, reconstructions using the ML-scaled scatter estimates are found to eliminate the typical 'halo' artifacts that are often observed in the vicinity of high focal uptake regions.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28737163      PMCID: PMC5748468          DOI: 10.1088/1361-6560/aa7a8c

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Energy-based scatter correction for 3-D PET scanners using NaI(T1) detectors.

Authors:  L E Adam; J S Karp; R Freifelder
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Physical and clinical performance of the mCT time-of-flight PET/CT scanner.

Authors:  B W Jakoby; Y Bercier; M Conti; M E Casey; B Bendriem; D W Townsend
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

3.  The performance of the single-slice rebinning technique for imaging the human striatum as evaluated by phantom studies.

Authors:  V Sossi; M W Stazyk; P E Kinahan; T J Ruth
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

4.  A convolution-subtraction scatter correction method for 3D PET.

Authors:  D L Bailey; S R Meikle
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

5.  Three-dimensional image reconstruction for PET by multi-slice rebinning and axial image filtering.

Authors:  R M Lewittt; G Muehllehner; J S Karpt
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

6.  Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

Authors:  Ahmadreza Rezaei; Michel Defrise; Girish Bal; Christian Michel; Maurizio Conti; Charles Watson; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2012-08-09       Impact factor: 10.048

7.  Model-based scatter correction for fully 3D PET.

Authors:  J M Ollinger
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

8.  Correction for scatter in 3D brain PET using a dual energy window method.

Authors:  S Grootoonk; T J Spinks; D Sashin; N M Spyrou; T Jones
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

9.  Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration.

Authors:  M E Casey; E J Hoffman
Journal:  J Comput Assist Tomogr       Date:  1986 Sep-Oct       Impact factor: 1.826

10.  Modelling Random Coincidences in Positron Emission Tomography by Using Singles and Prompts: A Comparison Study.

Authors:  Josep F Oliver; M Rafecas
Journal:  PLoS One       Date:  2016-09-07       Impact factor: 3.240

  10 in total
  4 in total

1.  Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.

Authors:  Ahmadreza Rezaei; Christophe M Deroose; Thomas Vahle; Fernando Boada; Johan Nuyts
Journal:  J Nucl Med       Date:  2018-03-01       Impact factor: 10.057

2.  Simultaneous whole-body 18F-PSMA-1007-PET/MRI with integrated high-resolution multiparametric imaging of the prostatic fossa for comprehensive oncological staging of patients with prostate cancer: a pilot study.

Authors:  Martin T Freitag; Claudia Kesch; Jens Cardinale; Paul Flechsig; Ralf Floca; Matthias Eiber; David Bonekamp; Jan P Radtke; Clemens Kratochwil; Klaus Kopka; Markus Hohenfellner; Albrecht Stenzinger; Heinz-Peter Schlemmer; Uwe Haberkorn; Frederik Giesel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-10-16       Impact factor: 9.236

3.  Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI.

Authors:  Thorsten Heußer; Philipp Mann; Christopher M Rank; Martin Schäfer; Antonia Dimitrakopoulou-Strauss; Heinz-Peter Schlemmer; Boris A Hadaschik; Klaus Kopka; Peter Bachert; Marc Kachelrieß; Martin T Freitag
Journal:  PLoS One       Date:  2017-08-17       Impact factor: 3.240

4.  Scatter Artifact with Ga-68-PSMA-11 PET: Severity Reduced With Furosemide Diuresis and Improved Scatter Correction.

Authors:  Courtney Lawhn-Heath; Robert R Flavell; David E Korenchan; Timothy Deller; Spencer Lake; Peter R Carroll; Thomas A Hope
Journal:  Mol Imaging       Date:  2018 Jan-Dec       Impact factor: 4.488

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.