Literature DB >> 28736947

Intraobserver and Interobserver Variability in Ultrasound Measurements of Thyroid Nodules.

Hyung Jin Lee1, Dae Young Yoon1, Young Lan Seo1, Jin Ho Kim1, Sora Baek1, Kyoung Ja Lim1, Young Kwon Cho1, Eun Joo Yun1.   

Abstract

OBJECTIVES: The purpose of this study was to assess the intraobserver and interobserver variability in ultrasound (US) measurements of thyroid nodules.
METHODS: We performed a prospective study of the US examinations of 73 patients with 122 thyroid nodules greater than 5 mm in size. Ultrasound measurements in 4 dimensions (anteroposterior, transverse, longitudinal, and maximum diameters) and measurement of the estimated volume (using the ellipsoid formula) of each thyroid nodule were performed twice by 2 independent radiologists (A and B, with 10 years and 6 months of experience, respectively). The intraobserver and interobserver variability in measurements of thyroid nodules was assessed by a Bland-Altman analysis of agreement. The absolute values for intraobserver and interobserver variability were compared by a paired t test.
RESULTS: The 95% intraobserver and interobserver limits of agreement for the anteroposterior, transverse, longitudinal, and maximum diameters and estimated volume of thyroid nodules were ±18.2%, ± 14.3%, and ±21.0%; ± 17.2%%, ± 17.3%, and 18.2%; ± 14.6%, ± 15.5%, and ±22.3%; ± 13.8%, ± 15.5%, and ±19.6%; and ±30.2%, ± 27.7%, and ±44.1%, respectively. The absolute values for intraobserver variability were lower than those for interobserver variability for all measurements.
CONCLUSIONS: There was considerable intraobserver and interobserver variability in US measurement of thyroid nodules, which must be taken into account during follow-up US examinations of patients with thyroid nodules.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  interobserver variability; intraobserver variability; measurement; thyroid nodule; thyroid/parathyroid; ultrasound

Mesh:

Year:  2017        PMID: 28736947     DOI: 10.1002/jum.14316

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  13 in total

1.  Application of deep learning to the diagnosis of cervical lymph node metastasis from thyroid cancer with CT.

Authors:  Jeong Hoon Lee; Eun Ju Ha; Ju Han Kim
Journal:  Eur Radiol       Date:  2019-03-15       Impact factor: 5.315

2.  Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound.

Authors:  Lin Yan; Yukun Luo; Jing Xiao; Lin Lin
Journal:  Eur Radiol       Date:  2020-10-31       Impact factor: 5.315

3.  Taller-Than-Wide Shape: A New Definition Improves the Specificity of TIRADS Systems.

Authors:  Giorgio Grani; Livia Lamartina; Valeria Ramundo; Rosa Falcone; Cristiano Lomonaco; Laura Ciotti; Martina Barone; Marianna Maranghi; Vito Cantisani; Sebastiano Filetti; Cosimo Durante
Journal:  Eur Thyroid J       Date:  2019-11-15

4.  2020 Chinese guidelines for ultrasound malignancy risk stratification of thyroid nodules: the C-TIRADS.

Authors:  JianQiao Zhou; LiXue Yin; Xi Wei; Sheng Zhang; YanYan Song; BaoMing Luo; JianChu Li; LinXue Qian; LiGang Cui; Wen Chen; ChaoYang Wen; YuLan Peng; Qin Chen; Man Lu; Min Chen; Rong Wu; Wei Zhou; EnSheng Xue; YingJia Li; LiChun Yang; ChengRong Mi; RuiFang Zhang; Gang Wu; GuoQing Du; DaoZhong Huang; WeiWei Zhan
Journal:  Endocrine       Date:  2020-08-21       Impact factor: 3.633

5.  An efficient deep convolutional neural network model for visual localization and automatic diagnosis of thyroid nodules on ultrasound images.

Authors:  Jialin Zhu; Sheng Zhang; Ruiguo Yu; Zhiqiang Liu; Hongyan Gao; Bing Yue; Xun Liu; Xiangqian Zheng; Ming Gao; Xi Wei
Journal:  Quant Imaging Med Surg       Date:  2021-04

6.  Value and Diagnostic Efficacy of Fetal Morphology Assessment Using Ultrasound in A Poor-Resource Setting.

Authors:  Ofonime N Ukweh; Theophilus I Ugbem; Chibuike M Okeke; Ernest U Ekpo
Journal:  Diagnostics (Basel)       Date:  2019-09-01

7.  Effect of the location and size of thyroid nodules on the diagnostic performance of ultrasound elastography: A retrospective analysis.

Authors:  Xinxin Xie; Yongqiang Yu
Journal:  Clinics (Sao Paulo)       Date:  2020-06-22       Impact factor: 2.365

8.  Ultrasound Cine Loop Standard Operating Procedure for Benign Thyroid Diseases-Evaluation of Non-Physician Application.

Authors:  Philipp Seifert; Ivonne Maikowski; Thomas Winkens; Christian Kühnel; Falk Gühne; Robert Drescher; Martin Freesmeyer
Journal:  Diagnostics (Basel)       Date:  2021-01-04

9.  Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results.

Authors:  Anna Skowrońska; Justyna Milczarek-Banach; Wiesław Wiechno; Witold Chudziński; Marcin Żach; Michał Mazurkiewicz; Piotr Miśkiewicz; Tomasz Bednarczuk
Journal:  Pol J Radiol       Date:  2018-12-19

10.  Ultrasonography for the Prediction of High-Volume Lymph Node Metastases in Papillary Thyroid Carcinoma: Should Surgeons Believe Ultrasound Results?

Authors:  Chunhao Liu; Lei Zhang; Yuewu Liu; Yu Xia; Yue Cao; Ziwen Liu; Ge Chen; Ning Liu; Zhonghua Shang; Jinbao Yang; Qinghe Sun; Xiaoyi Li
Journal:  World J Surg       Date:  2020-09-11       Impact factor: 3.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.