PURPOSE: To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging.
METHODS: A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board-approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting.
RESULTS: High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes).
CONCLUSIONS: High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon.

Entities:  

Mesh:

Year:  2011        PMID: 21282565      PMCID: PMC3109021          DOI: 10.1167/iovs.10-6720

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  17 in total

1.  Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography.

Authors:  Shuliang Jiao; Robert Knighton; Xiangrun Huang; Giovanni Gregori; Carmen Puliafito
Journal:  Opt Express       Date:  2005-01-24       Impact factor: 3.894

2.  Implementation of fiber tract navigation.

Authors:  Christopher Nimsky; Oliver Ganslandt; Rudolf Fahlbusch
Journal:  Neurosurgery       Date:  2007-07       Impact factor: 4.654

3.  A new concept for vitreous surgery. 4. Improvements in instrumentation and illumination.

Authors:  J M Parel; R Machemer; W Aumayr
Journal:  Am J Ophthalmol       Date:  1974-01       Impact factor: 5.258

4.  A new concept for vitreous surgery. 5. An automated operating microscope.

Authors:  J M Parel; R Machemer; W Aumayr
Journal:  Am J Ophthalmol       Date:  1974-02       Impact factor: 5.258

5.  A binocular indirect ophthalmomicroscope (BIOM) for non-contact wide-angle vitreous surgery.

Authors:  M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1987       Impact factor: 3.117

6.  Vitrectomy: a pars plana approach.

Authors:  R Machemer; H Buettner; E W Norton; J M Parel
Journal:  Trans Am Acad Ophthalmol Otolaryngol       Date:  1971 Jul-Aug

7.  Staining of internal limiting membrane in macular hole surgery.

Authors:  K Kadonosono; N Itoh; E Uchio; S Nakamura; S Ohno
Journal:  Arch Ophthalmol       Date:  2000-08

8.  Insights into advanced retinopathy of prematurity using handheld spectral domain optical coherence tomography imaging.

Authors:  Sai H Chavala; Sina Farsiu; Ramiro Maldonado; David K Wallace; Sharon F Freedman; Cynthia A Toth
Journal:  Ophthalmology       Date:  2009-09-18       Impact factor: 12.079

9.  Imaging the infant retina with a hand-held spectral-domain optical coherence tomography device.

Authors:  Adrienne W Scott; Sina Farsiu; Laura B Enyedi; David K Wallace; Cynthia A Toth
Journal:  Am J Ophthalmol       Date:  2008-10-09       Impact factor: 5.258

10.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation.

Authors:  Stephanie J Chiu; Xiao T Li; Peter Nicholas; Cynthia A Toth; Joseph A Izatt; Sina Farsiu
Journal:  Opt Express       Date:  2010-08-30       Impact factor: 3.894

View more
  66 in total

1.  Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers.

Authors:  Mohamed T El-Haddad; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2015-07-23       Impact factor: 3.732

Review 2.  Intraoperative optical coherence tomography: past, present, and future.

Authors:  J P Ehlers
Journal:  Eye (Lond)       Date:  2015-12-18       Impact factor: 3.775

3.  In vivo virtual intraoperative surgical photoacoustic microscopy.

Authors:  Seunghoon Han; Changho Lee; Sehui Kim; Mansik Jeon; Jeehyun Kim; Chulhong Kim
Journal:  Appl Phys Lett       Date:  2013-11-11       Impact factor: 3.791

4.  Microvascular anastomosis guidance and evaluation using real-time three-dimensional Fourier-domain Doppler optical coherence tomography.

Authors:  Yong Huang; Zuhaib Ibrahim; Dedi Tong; Shan Zhu; Qi Mao; John Pang; Wei Ping Andree Lee; Gerald Brandacher; Jin U Kang
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

5.  Miniature real-time intraoperative forward-imaging optical coherence tomography probe.

Authors:  Karen M Joos; Jin-Hui Shen
Journal:  Biomed Opt Express       Date:  2013-07-16       Impact factor: 3.732

Review 6.  Clinical utility of intraoperative optical coherence tomography.

Authors:  Mehnaz Khan; Justis P Ehlers
Journal:  Curr Opin Ophthalmol       Date:  2016-05       Impact factor: 3.761

7.  Motorized Micro-Forceps with Active Motion Guidance based on Common-Path SSOCT for Epiretinal Membranectomy.

Authors:  Gyeong Woo Cheon; Berk Gonenc; Russell H Taylor; Peter L Gehlbach; Jin U Kang
Journal:  IEEE ASME Trans Mechatron       Date:  2017-09-05       Impact factor: 5.303

8.  Intraoperative optical coherence tomography in macula involving rhegmatogenous retinal detachment repair with pars plana vitrectomy and perfluoron.

Authors:  O Toygar; C D Riemann
Journal:  Eye (Lond)       Date:  2015-12-11       Impact factor: 3.775

9.  Intraoperative optical coherence tomography-compatible surgical instruments for real-time image-guided ophthalmic surgery.

Authors:  Justis P Ehlers; Atsuro Uchida; Sunil K Srivastava
Journal:  Br J Ophthalmol       Date:  2017-07-20       Impact factor: 4.638

10.  Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.

Authors:  Paul Hahn; Justin Migacz; Rachelle O'Donnell; Shelley Day; Annie Lee; Phoebe Lin; Robin Vann; Anthony Kuo; Sharon Fekrat; Prithvi Mruthyunjaya; Eric A Postel; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2013 Jul-Aug       Impact factor: 4.256

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.