Literature DB >> 28728009

Bridged Rebar Graphene functionalized aptasensor for pathogenic E. coli O78:K80:H11 detection.

Harmanjit Kaur1, Munish Shorie1, Manju Sharma1, Ashok K Ganguli2, Priyanka Sabherwal3.   

Abstract

We report a novel fabrication method of functionalised Bridged Rebar Graphene (BRG) onto newly designed nanostructured aptasensor for label free impedimetric sensing of pathogenic bacteria E. coli O78:K80:H11. The chemical facilitated unscrolling of MWCNT and subsequent bridging with terephthalaldehyde (TPA) to form 3D-hierarchical BRG nanoconstruct exhibited synergistic effect by combining enhanced electrical properties and facile chemical functionality for stable bio-interface. The bacteria-DNA interactions were captured on BRG nanostructured electrode by using specific anti-E.coli DNA aptamer (Kd~ 14nM), screened by new in-situ developed SELEX method using phenylboronic acid on microtitre plate. The developed nanostructured aptasensor demonstrated a low detection limit and sensitivity of ~ 101cfu/mL towards E. coli O78:K80:H11 with a dynamic response range from 101 to 106cfu/mL in water, juice and milk samples.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bacteria detection; Bridged Rebar Graphene; Cell-SELEX; DNA aptamer; Impedimetric aptasensor; Pathogenic E.coli

Mesh:

Substances:

Year:  2017        PMID: 28728009     DOI: 10.1016/j.bios.2017.07.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  15 in total

Review 1.  Selection of aptamers against pathogenic bacteria and their diagnostics application.

Authors:  Lijun Wang; Ronghui Wang; Hua Wei; Yanbin Li
Journal:  World J Microbiol Biotechnol       Date:  2018-09-15       Impact factor: 3.312

2.  Plasmonic DNA hotspots made from tungsten disulfide nanosheets and gold nanoparticles for ultrasensitive aptamer-based SERS detection of myoglobin.

Authors:  Munish Shorie; Vinod Kumar; Harmanjit Kaur; Kulvinder Singh; Vijay K Tomer; Priyanka Sabherwal
Journal:  Mikrochim Acta       Date:  2018-02-05       Impact factor: 5.833

3.  An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode.

Authors:  Seyed Sanaan Zarei; Sabihe Soleimanian-Zad; Ali A Ensafi
Journal:  Mikrochim Acta       Date:  2018-11-09       Impact factor: 5.833

4.  Microtitre Plate Based Cell-SELEX Method.

Authors:  Munish Shorie; Harmanjit Kaur
Journal:  Bio Protoc       Date:  2018-10-20

Review 5.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

Review 6.  Electrochemical Biosensors in Food Safety: Challenges and Perspectives.

Authors:  Antonella Curulli
Journal:  Molecules       Date:  2021-05-15       Impact factor: 4.411

7.  Covalent capture and electrochemical quantification of pathogenic E. coli.

Authors:  Sarah H Klass; Laura E Sofen; Zachary F Hallberg; Tahoe A Fiala; Alexandra V Ramsey; Nicholas S Dolan; Matthew B Francis; Ariel L Furst
Journal:  Chem Commun (Camb)       Date:  2021-03-09       Impact factor: 6.065

Review 8.  Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.

Authors:  Xuan Liu; Hui Jiang
Journal:  Sensors (Basel)       Date:  2017-12-04       Impact factor: 3.576

Review 9.  Two-Dimensional Nanostructures for Electrochemical Biosensor.

Authors:  Reem Khan; Antonio Radoi; Sidra Rashid; Akhtar Hayat; Alina Vasilescu; Silvana Andreescu
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

Review 10.  Application of Aptamer-Based Biosensor for Rapid Detection of Pathogenic Escherichia coli.

Authors:  Yu-Wen Zhao; Hai-Xia Wang; Guang-Cheng Jia; Zheng Li
Journal:  Sensors (Basel)       Date:  2018-08-01       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.