Yurday Ozdemir1, Yemliha Dolek1, Cem Onal1.
Abstract
PURPOSE: To investigate the impact of different cylinder positions on dosimetry of critical structures in patients with endometrial carcinoma undergoing three-dimensional image-based vaginal cuff brachytherapy (VCB).Entities:
Keywords: EQD2; brachytherapy; cylinder positions; endometrial cancer
Year: 2017 PMID: 28725246 PMCID: PMC5509981 DOI: 10.5114/jcb.2017.68171
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Fig. 1The 4 Gy isodose area (red) according to the vaginal cylinder in the (A) neutral, (B) parallel, and (C) angled positions in a representative patient
Dose levels to the rectum according to the cylinder positions in vaginal cuff brachytherapy (VCB) and equivalent dose calculated in 2 Gy (EQD2) of external beam radiotherapy
| Cases | EQD2 EBRT (1.8 Gy × 25 fx) | VCB (fx) | D2cc (fx/Gy) | D0.1cc (fx/Gy) | D1cc (fx/Gy) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| N | P | A | N | P | A | N | P | A | |||
| 1 | 43.2 | 3 | 4.9 | 4.5 | 4.5 | 6.4 | 6.3 | 5.6 | 5.2 | 4.8 | 5.1 |
| 2 | 43.2 | 3 | 5.2 | 4.5 | 4.5 | 6.5 | 6.2 | 5.4 | 5.5 | 4.8 | 4.9 |
| 3 | 43.2 | 3 | 5.3 | 4.8 | 3.7 | 6.2 | 5.9 | 4.6 | 5.8 | 5.1 | 4.0 |
| 4 | 43.2 | 3 | 5.6 | 3.2 | 4.4 | 7.2 | 3.9 | 5.5 | 6.2 | 3.5 | 4.7 |
| 5 | 43.2 | 3 | 4.9 | 4.8 | 5.6 | 6.3 | 5.7 | 8.3 | 5.2 | 5.1 | 6.0 |
| 6 | 43.2 | 3 | 5.4 | 4.9 | 4.2 | 6.4 | 6.3 | 5.1 | 5.4 | 5.5 | 4.4 |
| 7 | 43.2 | 3 | 5.2 | 5.2 | 4.7 | 5.3 | 5.6 | 5.6 | 5.4 | 5.4 | 4.9 |
| 8 | 43.2 | 3 | 5.1 | 4.7 | 4.1 | 6.6 | 5.4 | 4.9 | 5.4 | 4.9 | 4.4 |
| 9 | 43.2 | 3 | 4.0 | 3.6 | 3.8 | 4.9 | 4.1 | 4.5 | 4.3 | 3.8 | 4.0 |
| 10 | 43.2 | 3 | 6.0 | 5.1 | 5.0 | 8.4 | 6.1 | 5.5 | 7.2 | 5.5 | 5.3 |
| 11 | 43.2 | 3 | 5.3 | 4.7 | 4.9 | 6.3 | 5.9 | 5.9 | 5.6 | 4.9 | 5.2 |
| 12 | 43.2 | 3 | 5.0 | 4.4 | 4.2 | 6.3 | 5.1 | 5.1 | 5.2 | 4.6 | 4.5 |
| 13 | 43.2 | 3 | 3.8 | 5.2 | 3.8 | 5.1 | 8.1 | 5.1 | 4.2 | 5.8 | 4.2 |
| 14 | 43.2 | 3 | 6.4 | 4.7 | 4.6 | 9.2 | 8.8 | 5.6 | 7.5 | 5.7 | 5.1 |
| 15 | 43.2 | 3 | 4.1 | 4.1 | 4.1 | 4.9 | 4.6 | 5.1 | 4.3 | 3.6 | 4.4 |
EQD2 – equivalent dose calculated in 2 Gy, Gy – gray, fx –fractions, D2cc, 0.1cc, 1cc – the minimum dose to the most irradiated of 2 cc, 0.1 cc, and 1 cc of organ, VCB – vaginal cuff brachytherapy, N, P, A – neutral, parallel, and angled cylinder positions, respectively
Mean rectum dose statistics according to the vaginal cylinder positions for one fraction of brachytherapy
| Rectal dose statistics | Cylinder position | |||||
|---|---|---|---|---|---|---|
| N (Gy ± SD) | P (Gy ± SD) | A (Gy ± SD) | N vs. P | N vs. A | P vs. A | |
| D2cc | 5.1 ± 0.7 | 4.5 ± 0.6 | 4.4 ± 0.5 | 0.013 | 0.001 | 0.6 |
| D0.1cc | 6.4 ± 1.2 | 5.9 ± 1.3 | 5.5 ± 0.9 | 0.15 | 0.001 | 0.3 |
| D1cc | 5.5 ± 0.9 | 4.9 ± 0.7 | 4.7 ± 0.6 | 0.03 | 0.005 | 0.5 |
N – neutral, P – parallel, A – angled, D2cc, 0.1cc, 1cc – the minimum dose to the most irradiated of 2 cc, 0.1 cc, and 1 cc of organ, Gy – gray
Total* rectal doses according to cylinder position
| Dose-volume parameters | Cylinder position | |||||
|---|---|---|---|---|---|---|
| N (Gy ± SD) | P (Gy ± SD) | A (Gy ± SD) | N vs. P | N vs. A | P vs. A | |
| D2cc | 67.3 ± 5.5 | 63.4 ± 4.8 | 62.1 ± 3.8 | 0.028 | 0.002 | 0.34 |
| D0.1cc | 79.3 ± 12 | 73.1 ± 12.3 | 70.5 ± 8.4 | 0.08 | 0.028 | 0.49 |
| D1cc | 70.9 ± 8.4 | 66.1 ± 5.6 | 64.5 ± 4.3 | 0.043 | 0.007 | 0.35 |
Total dose is provided in equivalent dose calculated in 2 Gy (EQD2) and EQD2 is calculated as EQD2 EBRT + EQD2 VCB. The EQD2 VCB was calculated based on the D2cc, 0.1cc, 1cc values presented in Table 1. The EQD2 EBRT was calculated for the total EBRT fractions EBRT – external beam radiotherapy, VCB – vaginal cuff brachytherapy, Gy – gray, N – neutral, P – parallel, A – angled, D2cc, 0.1cc, 1cc – the minimum dose to the most irradiated of 2 cc, 0.1 cc, and 1 cc of organ
Fig. 2Comparative dose-volume histogram of the (A) rectum and (B) bladder according to the vaginal cylinder in the neutral (triangle), parallel (square), and angled (sphere) positions