Literature DB >> 11932216

The influence of applicator angle on dosimetry in vaginal vault brachytherapy.

P J Hoskin1, P Bownes, A Summers.   

Abstract

In vaginal vault brachytherapy, the critical normal tissues are bladder and rectum; doses to these tissues may be affected by the position of a single line applicator placed in the vagina. Dosimetry with the applicator lying at its "natural" angle in the vagina with the patient in the lithotomy position has been compared with the applicator held horizontal as defined by a spirit level in 30 consecutive patients. A mean change in angle of 19.7 degrees was found. This resulted in a mean decrease in ICRU (International Commission of Radiation Units and Measurements) rectal point dose when the applicator is horizontal of 12.9%, equivalent to a mean absolute dose reduction of 1.3 Gy for a prescription dose of 5.5 Gy at 5 mm depth. An increase in mean dose to the ICRU bladder point when the applicator is horizontal of 13.3%, equivalent to an absolute mean dose increase of 0.5 Gy per fraction for the same prescription dose, was also found. On the basis of these findings, it is recommended that vaginal vault brachytherapy is performed with a single line source held in the "corrected" horizontal position to reduce bowel dose as this is the most sensitive critical normal tissue.

Entities:  

Mesh:

Year:  2002        PMID: 11932216     DOI: 10.1259/bjr.75.891.750234

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  Reduction of rectal doses by removal of gas in the rectum during vaginal cuff brachytherapy.

Authors:  S Sabater; Ma M Sevillano; I Andres; R Berenguer; S Machin-Hamalainen; K Müller; M Arenas
Journal:  Strahlenther Onkol       Date:  2013-09-04       Impact factor: 3.621

Review 2.  American Brachytherapy Task Group Report: Adjuvant vaginal brachytherapy for early-stage endometrial cancer: A comprehensive review.

Authors:  Matthew M Harkenrider; Alec M Block; Kaled M Alektiar; David K Gaffney; Ellen Jones; Ann Klopp; Akila N Viswanathan; William Small
Journal:  Brachytherapy       Date:  2016-05-31       Impact factor: 2.362

3.  Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy: A prospective trial.

Authors:  Sebastià Sabater; Ignacio Andrés; Marina Gascon; Angeles Rovirosa; Marimar Sevillano; Roberto Berenguer; Cristina Camacho-Lopez; Manuel Aguayo; Maria Victoria Villas; Meritxell Arenas
Journal:  Strahlenther Onkol       Date:  2016-01-23       Impact factor: 3.621

4.  Prospective clinical trial of bladder filling and three-dimensional dosimetry in high-dose-rate vaginal cuff brachytherapy.

Authors:  Alexandra J Stewart; Robert A Cormack; Hang Lee; Li Xiong; Jorgen L Hansen; Desmond A O'Farrell; Akila N Viswanathan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-04-18       Impact factor: 7.038

5.  Body Mass Index and Doses at Organs at Risk in a Mediterranean Population Treated with Postoperative Vaginal Cuff Brachytherapy.

Authors:  Sebastia Sabater; Meritxell Arenas; Roberto Berenguer; Ignacio Andres; Esther Jimenez-Jimenez; Ana Martos; Jesus Fernandez-Lopez; Mar Sevillano; Angeles Rovirosa
Journal:  Cancer Res Treat       Date:  2014-11-24       Impact factor: 4.679

6.  Study of positional dependence of dose to bladder, pelvic wall and rectal points in High-Dose-Rate Brachytherapy in cervical cancer patients.

Authors:  Anil Kumar Talluri; Krishnam Raju Alluri; Deleep Kumar Gudipudi; Shabbir Ahamed; Madhusudhana M Sresty; Aparna Yarrama Reddy
Journal:  J Med Phys       Date:  2013-10

Review 7.  Vaginal cuff brachytherapy in endometrial cancer - a technically easy treatment?

Authors:  Sebastià Sabater; Ignacio Andres; Veronica Lopez-Honrubia; Roberto Berenguer; Marimar Sevillano; Esther Jimenez-Jimenez; Angeles Rovirosa; Meritxell Arenas
Journal:  Cancer Manag Res       Date:  2017-08-09       Impact factor: 3.989

8.  Volumetric (3D) bladder dose parameters are more reproducible than point (2D) dose parameters in vaginal vault high-dose-rate brachytherapy.

Authors:  Lucas Gomes Sapienza; Adriana Flosi; Antonio Aiza; Antonio Cassio de Assis Pellizzon; Rubens Chojniak; Glauco Baiocchi
Journal:  Sci Rep       Date:  2016-06-14       Impact factor: 4.379

9.  Effects of vaginal cylinder position on dose distribution in patients with endometrial carcinoma in treatment of vaginal cuff brachytherapy.

Authors:  Yurday Ozdemir; Yemliha Dolek; Cem Onal
Journal:  J Contemp Brachytherapy       Date:  2017-06-05

10.  Clinical and Dosimetric Implications of Intrafractional Cylinder Movement During Vaginal Cuff Brachytherapy.

Authors:  Benjamin E Onderdonk; Tianming Wu; Hania Al-Hallaq; Christina H Son; Joseph Waller; Yasmin Hasan
Journal:  Cureus       Date:  2019-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.