Literature DB >> 28724287

Active Solvent Modulation: A Valve-Based Approach To Improve Separation Compatibility in Two-Dimensional Liquid Chromatography.

Dwight R Stoll1, Konstantin Shoykhet2, Patrik Petersson3, Stephan Buckenmaier2.   

Abstract

Two-dimensional liquid chromatography (2D-LC) is increasingly being viewed as a viable tool for solving difficult separation problems, ranging from targeted separations of structurally similar molecules to untargeted separations of highly complex mixtures. In spite of this performance potential, though, many users find method development challenging and most frequently cite the "incompatibility" between the solvent systems used in the first and second dimensions as a major obstacle. This solvent strength related incompatibility can lead to severe peak distortion and loss of resolution and sensitivity in the second dimension. In this paper, we describe a novel approach to address the incompatibility problem, which we refer to as Active Solvent Modulation (ASM). This valve-based approach enables dilution of 1D effluent with weak solvent prior to transfer to the 2D column but without the need for additional instrument hardware. ASM is related to the concept we refer to as Fixed Solvent Modulation (FSM), with the important difference being that ASM allows toggling of the diluent stream during each 2D separation cycle. In this work, we show that ASM eliminates the major drawbacks of FSM including complex elution solvent profiles, baseline disturbances, and slow 2D re-equilibration and demonstrate improvements in 2D separation quality using both simple small molecule probes and degradants of heat-treated bovine insulin as case studies. We believe that ASM will significantly ease method development for 2D-LC, providing a path to practical methods that involve both highly complementary 1D and 2D separations and sensitive detection.

Entities:  

Year:  2017        PMID: 28724287     DOI: 10.1021/acs.analchem.7b02046

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Online Nanoflow Two-Dimension Comprehensive Active Modulation Reversed Phase-Reversed Phase Liquid Chromatography High-Resolution Mass Spectrometry for Metaproteomics of Environmental and Microbiome Samples.

Authors:  Matthew R McIlvin; Mak A Saito
Journal:  J Proteome Res       Date:  2021-08-12       Impact factor: 4.466

2.  Peak-Tracking Algorithm for Use in Automated Interpretive Method-Development Tools in Liquid Chromatography.

Authors:  Bob W J Pirok; Stef R A Molenaar; Liana S Roca; Peter J Schoenmakers
Journal:  Anal Chem       Date:  2018-11-15       Impact factor: 6.986

3.  Rapid two-dimensional Protein-A size exclusion chromatography of monoclonal antibodies for titer and aggregation measurements from harvested cell culture fluid samples.

Authors:  Zachary D Dunn; Jayesh Desai; Gabriel M Leme; Dwight R Stoll; Douglas D Richardson
Journal:  MAbs       Date:  2020 Jan-Dec       Impact factor: 5.857

Review 4.  Optimizing separations in online comprehensive two-dimensional liquid chromatography.

Authors:  Bob W J Pirok; Andrea F G Gargano; Peter J Schoenmakers
Journal:  J Sep Sci       Date:  2017-11-23       Impact factor: 3.645

5.  Application of the new at-column dilution (ACD) modulator for the two-dimensional RP×HILIC analysis of Buddleja davidii.

Authors:  Yingzhuang Chen; Lidia Montero; Jiang Luo; Junjie Li; Oliver J Schmitz
Journal:  Anal Bioanal Chem       Date:  2020-01-21       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.