Bob W J Pirok1,2, Stef R A Molenaar1, Liana S Roca1, Peter J Schoenmakers1. 1. van 't Hoff Institute for Molecular Sciences, Analytical Chemistry Group , University of Amsterdam , Science Park 904 , 1098 XH Amsterdam , The Netherlands. 2. TI-COAST , Science Park 904 , 1098 XH Amsterdam , The Netherlands.
Abstract
A peak-tracking algorithm for chromatograms recorded using liquid chromatography and mass spectrometry was developed. Peaks are tracked across chromatograms using the spectrometric information, the statistical moments of the chromatographic peaks, and the relative retention. The algorithm can be applied to pair chromatographic peaks in two very different chromatograms, obtained for different samples using different methods. A fast version of the algorithm was specifically tailored to process chromatograms obtained during method development or optimization, where a few similar mobile-phase-composition gradients (same eluent components, but different ranges and programming rates) are applied to the same sample for the purpose of obtaining model parameters to describe the retention of sample components. Due to the relative similarity between chromatograms, time-saving preselection protocols can be used to locate a candidate peak in another chromatogram. The algorithm was applied to two different samples featuring isomers. The automatically tracked peaks and the resulting retention parameters generally yielded prediction errors of less than 1%.
A peak-tracking algorithm for chromatograms recorded using liquid chromatography and mass spectrometry was developed. Peaks are tracked across chromatograms using the spectrometric information, the statistical moments of the chromatographic peaks, and the relative retention. The algorithm can be applied to pair chromatographic peaks in two very different chromatograms, obtained for different samples using different methods. A fast version of the algorithm was specifically tailored to process chromatograms obtained during method development or optimization, where a few similar mobile-phase-composition gradients (same eluent components, but different ranges and programming rates) are applied to the same sample for the purpose of obtaining model parameters to describe the retention of sample components. Due to the relative similarity between chromatograms, time-saving preselection protocols can be used to locate a candidate peak in another chromatogram. The algorithm was applied to two different samples featuring isomers. The automatically tracked peaks and the resulting retention parameters generally yielded prediction errors of less than 1%.
Liquid chromatography
(LC) is
one of the most established and useful tools for the analytical chemist.
In recent years, developments including ultrahigh-pressure operation,
core–shell particles, and monolithic stationary phases have
improved the technique further, and hyphenation with powerful detectors,
such as mass spectrometers, has rendered LC indispensable in the analytical
lab. For very complex samples, for which more resolving power is needed,
(comprehensive) two-dimensional (2D) liquid chromatography is a valuable
addition. In recent years, this latter technique has been maturing
rapidly. Advanced modulation interfaces have significantly reduced
the threats of solvent incompatibility[1,2] and limited
detector sensitivity[3] in the comprehensive
mode (LC × LC).[4] However, these developments
are accompanied by an increase in the complexity of the system and,
thus, the time required for method development. This is not only important
in the case of two-dimensional LC, where essentially two complementary
LC methods are required both in heart-cut 2D-LC and in LC × LC.[5] Method development is also critical in 1D-LC.
For example, in the emerging field of biopharmaceuticals, including
biosimilars, many difficult questions arise, and very efficient method
development is needed.The prospect of cumbersome method development
looms as a millstone
around the neck of chromatographers, and this has spurred the development
of computer-aided method-development tools. Research in such tools
can roughly be categorized in two major categories, viz., (i) tools
that rely on very large sets (>200 experiments) of data to train
an
algorithm in modeling the data[6,7] and (ii) tools that
describe component retention with relatively simple (physicochemical
interaction or empirical) models. In the first case, no knowledge
on the retention mechanism is required. However, the requirement of
recording hundreds of experiments tailored to the analytes of interest
is daunting. Moreover, the obtained models are not related to the
physicochemical interactions that take place in the column. This latter
aspect renders the models vulnerable if they are extrapolated to analytes
or conditions outside the training set.In the second case,
a thorough understanding of the physicochemical
interactions is crucial to derive a robust strategy to address unknown
analytes and unexplored conditions. This type of strategy is routinely
applied by optimization approaches such as DryLab[8] and PEWS[9] in 1D-LC and PIOTR[10] in both 1D- and 2D-LC. Typically, gradient-scanning
techniques are used, where two to three chromatograms are recorded
of the same sample using a different gradient slope (and possibly
different initial and/or final compositions). The peaks of sample
analytes are then matched (or “paired”) across the recorded
chromatograms and a physicochemical retention model is derived from
the retention times. The retention parameters for all analytes are
then used to predict the results of potential methods. Readers interested
in this approach are referred to useful works.[4,9,10] In the case of the PIOTR program, Pareto
optimality analysis is used to identify methods, which meet user-defined
optimization objectives. The PIOTR approach allows (LC × LC)
method-development times to be reduced from several months to a few
days.[10]For such approaches to run
as automatically as possible, the computer
program must be able to efficiently track the different peaks found
in all scanned chromatograms, i.e., decide which peaks in the different
chromatograms belong to the same analyte. Especially in LC ×
LC, the number of possible analytes is vast, for example, when protein
digest samples are targeted. In such a case manual peak tracking may
form a new millstone around the chromatographer’s neck.In comprehensive two-dimensional gas chromatography (GC ×
GC) algorithms have been developed to track peaks across chromatograms
automatically.[11] However, one critical
difference between GC × GC and LC × LC is that in the latter
case the elution order of peaks is subject to more dramatic changes.
As a result, existing algorithms cannot easily be applied. In 1D-LC,
already in the late 1980s peak-tracking strategies were developed
that exclusively relied on chromatographic band areas[12] or spectroscopic data.[13] More
recently, the group of Bylund proposed and tested an integrated statistical
approach for tracking components in liquid chromatography–mass
spectrometry (LC–MS) methods.[14,15]Seeking
an integrated, comprehensive package for both 1D and 2D
separations, we initiated the development of a peak-pairing algorithm
that would combine chromatographic and spectral information to pair
chromatographic signals across a number of chromatograms, while simultaneously
allowing us to correctly assign isomer species and to distinguish
between true peaks and system/background peaks.A secondary
objective of the algorithm involves cases in which
the number of detected peaks is vast and/or analytes might be present
at trace concentrations. In such a case a successful algorithm may
contribute to the discovery of untargeted analytes in the sample.
In practice, signals that barely meet the minimum signal-to-noise
ratio may easily be (accidentally) excluded by the user. This is not
avoided when a peak-detection algorithm is used, because such a tool
mathematically treats all signals that meet the criteria similarly
and may also detect peaks which are not of interest (e.g., noise peaks).
However, a peak-tracking algorithm which compares chromatographic
and spectral features of each detected signal can determine the similarity
between these signals across chromatograms. Therefore, in the event
that apparent noise or a baseline irregularity can be matched with
a similar signal in another chromatogram based on similarity between
spectral and chromatographic data, the likelihood of the signal representing
a real peak rather than an irregularity increases greatly. Thus, through
comparison of all peak features across the chromatograms, the algorithm
may discover peaks that would be difficult to find manually.In this paper, we present a novel combination of algorithms to
track untargeted and unidentified peaks across LC–MS separations
through comparison of chromatographic and spectral information. The
algorithm is described in detail, and it is explored how the available
data can be used to reduce the number of possible candidates. The
performance of the algorithm is tested on two degraded dye mixtures
separated by reversed-phase LC (RPLC) and a mixture of metabolites
separated by hydrophilic-interaction LC (HILIC). The dye mixtures
contain a number of (coeluting) isomer peaks to obtain insight in
the robustness of the algorithms in case of coelution and the presence
of isomers. The tracked peaks are used to predict retention times
for a new method, and the results are compared with experimental values
to assess the accuracy.
Theory
One important aspect of a
practical peak-tracking algorithm is
efficient use of computational resources. A reasonable balance must
be found between the use of computational/time resources and tracking
performance. Figure shows a decision flowchart of the overall algorithm. The overall
algorithm was composed in several blocks, each targeting different
objectives, viz., (1) preparation, (2) comparison, and (3) evaluation.
Each block comprises several steps which are denoted with capital
characters (A, B, C, etc.) in Figure . In this section, the theoretical functionality of
each block will be discussed; references to the different steps will
be made.
Figure 1
Scheme depicting the decision flowchart of the peak-tracking algorithm.
Scheme depicting the decision flowchart of the peak-tracking algorithm.
Preparation of the Data
The preparation
block of the
algorithm aims to reliably reduce the number of potential candidates
for tracking evaluation. Depending on the sampling frequency a chromatogram
of, say, 30 min may easily contain hundreds if not thousands of mathematically
identified peaks. Comparing all chromatographic and spectral information
on every possible peak pair would require extreme computational power.
By excluding system/noise bands (Figure , steps 1A/B) and using retention patterns
(Figure , step 1C)
to preselect a logical domain of possible pairs (Figure , step 1D), the computational
resources required can be significantly reduced.
Peak Detection
The first step (Figure , step 1A) is generic peak detection across
the chromatogram. The peak-detection algorithm developed by Peters
et al. was applied to generate an array of candidate peaks.[16] A relatively sensitive detection threshold was
typically used in this study, i.e., the maximum observed intensity
(Imax) divided by 10 000 (Imax/10 000). This allowed untargeted
peaks at very low concentrations to be detected. In cases in which
all peaks are of low intensity, such a sensitive setting may generate
too many candidates, but this should automatically be corrected in
the next step (Figure ). The above setting worked satisfactory for all examples shown in
this publication, but it is one of several overall input parameters
that the eventual end-user of the system may tweak.
Filtering of
Background Signals
After generating the
initial list of candidates, all spurious peaks (i.e., baseline noise
or irregularities) must be filtered out (Figure , step 1B). The algorithm selects a number
of spectrometric information points at minimal intensities across
the chromatogram to establish a generic spectrum of the background
signal. All spectra are reduced to the most prominent mass (i.e.,
the intensity of all other masses is set to equal 0). This process
is carried out for all chromatograms in which peaks are to be tracked,
and the final result is compared. The algorithm defines this as the
background signal. Next, all detected peaks of which the spectrum
matches the background spectrum are removed from the candidate list.
To enhance the accuracy, the background spectrum can easily be extended
to include the n most dominant peaks, but no substantial
benefit of such an expansion was observed. While, theoretically, all
remaining candidates should derive from the sample mixture, there
is still a possibility that this is not the case. The existence of
erroneous peaks in the remaining pool of candidates does not dramatically
affect the algorithm, because they are unlikely to be paired with
unique sample components. However, non-sample peaks will increase
the number of candidates and thus slow the entire process down.
Reduction of the Number of Candidate Pairs: Recognition of Retention
Pattern and Definition of Spread
Having filtered out the
background peaks, further reduction of the number of candidate pairs
across chromatograms is still required. For example, if both chromatograms
contain, say, 30 remaining candidates, then an unbiased algorithm
should theoretically assess 900 possible pairs based on both chromatographic
and spectral information, which is time-consuming. Indeed, the drain
on computational resources may be significantly reduced if the algorithm
is equipped with a search function.To understand this we regard Figure A, which portrays
an m-by-n matrix of all possible
combinations of peaks for a hypothetical case of two chromatograms.
Here, every box represents one possible combination, which—without
a search function—would all have to be evaluated. The colored
boxes will gradually be introduced in the course of this section.
For now we will focus on the size of the search window (highlighted
in blue) and how it is established.
Figure 2
Matrix depicting the selection of logical
combinations of peaks
between two hypothetical chromatograms m and n, and definition of the required search window (highlighted
in blue) using the (A) diagonal and (B) relative retention method.
The subsequent residual possible combinations for the evaluation block
of the algorithm (Figure , block 3) are reflected in panels C and D, respectively.
See text for further clarification on the colored boxes.
Matrix depicting the selection of logical
combinations of peaks
between two hypothetical chromatograms m and n, and definition of the required search window (highlighted
in blue) using the (A) diagonal and (B) relative retention method.
The subsequent residual possible combinations for the evaluation block
of the algorithm (Figure , block 3) are reflected in panels C and D, respectively.
See text for further clarification on the colored boxes.While the elution order may potentially be altered,
it is not likely
that the elution order will shift dramatically across two different
scanning gradients. Exaggerating, the first-eluting peak in chromatogram m is unlikely to match the last-eluting peak in chromatogram n if only the gradient conditions are changed.To
greatly reduce the number of possible pairs, the algorithm may
exclusively evaluate pairs along the diagonal of the matrix within
a range, ω; this “diagonal” method is illustrated
in Figure A. Here,
the diagonal represents an identical elution order and the width of
the window accounts for shifts in elution order. At this stage, the
algorithm will only evaluate combinations within this range and thus
ignore combinations depicted as gray boxes. This relatively narrow
window can fairly be assumed to allow pairing of a significant fraction
of the true peak pairs as is depicted by the green boxes in Figure A. Consequently,
the remaining possible pairs for later evaluation (Figure C, light blue boxes) can also
be expected to be small in number, allowing the algorithm to overall
swiftly track the residual peaks (Figure C, dark blue).In practice, however,
we found the remaining number of detected
peaks after preprocessing to be quite variable. The case displayed
in Figure A assumes
that the initially unpaired peaks are spread evenly across the first
chromatogram, but in practice this does not have to be true. For example,
the red boxes reflect a true combination which fell outside of the
search window. Alternative, two peaks in one chromatogram might both
be candidates for one peak in the other chromatogram (e.g., resolved
isomers) such as depicted by the orange boxes. However, the purple
boxes depict a case where one was outside of the window. Consequently,
the algorithm might wrongly conclude it found the true peak, requiring
more exhaustive computations during the evaluation step to undo this
mistake.The diagonal method described above applies a search
window to
the matrix. It selects boxes on the diagonal plus a number ω
of boxes around it. However, if a candidate peak is nested in a relatively
densely populated area of the chromatogram, more neighbors may be
considered. Therefore, the algorithm was expanded so as to search
for likely mean relative retention times () between
peaks in two chromatograms (Figure B, relative retention
method). Here, the algorithm does not apply a search window to the
matrix, but to the chromatograms (Figure ).
Figure 3
Example of the determination of the mean relative
retention time
() between
two chromatograms and the corresponding
search window. By using , the algorithm applies the search window
to the chromatogram, and not to the matrix. Consequently, this function
is more robust to variations in peak density in the chromatograms.
Note that the scheme displays a simple hypothetical case for explanatory
purposes.
Example of the determination of the mean relative
retention time
() between
two chromatograms and the corresponding
search window. By using , the algorithm applies the search window
to the chromatogram, and not to the matrix. Consequently, this function
is more robust to variations in peak density in the chromatograms.
Note that the scheme displays a simple hypothetical case for explanatory
purposes.To define , the
peaks for each chromatogram are ranked
according to intensity and the x most intense peaks
are selected for each, as can be seen in Figure . Assuming that these most intense peaks
include likely pairs, the algorithm calculates the relative retention tR,rel for each peak pair. When recording chromatograms
using gradient-scanning techniques, the different gradient slopes
used in the different methods typically result in proportionally different
retention times. As such, tR,rel for retained
peaks is likely to be similar. The algorithm therefore evaluates whether
the element A(i) is greater than
3 times the scaled median absolute derivative (MAD)[17] defined aswhere A represents
the vector
of tR,rel values and s is a scaling factor which equals 1.4826. If the rank order changed
due to variation in signal intensity, tR,rel will automatically be recognized as an outlier, unless tR,rel of both pairs is similar (e.g., due to coelution)
and tR,rel would be similar and there
would be no significant negative effect. Moreover, all pairs are removed
that were either unretained or unaffected by the gradient (i.e., system
peaks or unretained peaks where tR,rel is close to 1), effectively filtering out everything meeting the
criterion of eq .The mean can then be taken of the remaining
list of relative retention times to obtain where,
similarly as in the example of Figure A, a window of allowed
variation can be set to allow for shifts in retention order. In essence,
the algorithm will only consider a limited number of candidates for
every peak as is reflected in Figure for the peak marked with X. This dynamic approach
is depicted in Figure B (see Supporting Information Section S-1 for a real example). In this work, this window was set to 25% (in
both directions). A smaller spread will improve the speed of the algorithm
at the risk of missing pairs.Figure D displays
an example of the effect of this preselection method on the matrix
of possible peak-pair combinations in the evaluation block of the
algorithm (Figure , block 3; to be addressed later). Indeed, for chromatograms recorded
using gradient scanning, the likelihood that the correct candidates
are paired increases compared to the diagonal approach (Figure A).The ranking step
relies on similar peaks appearing in all chromatograms
to be paired (i.e., similar or identical analytes) in plausible positions
(i.e., by using similar, logically different methods), as is the case
for gradient-scanning techniques, where the gradient slope is typically
varied and analytes are expected to elute around a proportionally
different locations. In case of tracking peaks across chromatograms
recorded using different samples, the diagonal method described in Figure A can be used. If
also the methods used are entirely different [e.g., when searching
for orthogonal methods in a comprehensive two-dimensional liquid chromatography
(LC × LC) approach], then the entire module of the algorithm
described in the Reduction of the Number of Candidate
Pairs section must be turned off and the overall speed will
be significantly reduced from (less than) 1 min to (several) hours.Regardless of the route taken, the process detailed in this section
will produce a matrix of candidate peak pairs between chromatograms m and n that fall within the search window.
This matrix will henceforth be called X.
Comparison
The established array of logical combinations X(m,n) (Figure , parts A or B, blue bins)
is transferred to the next block of the algorithm, where spectrometric
and chromatographic information is compared for each possible pair.
In this section, the steps taken to evaluate a possible pair m,n and to determine whether the peaks
are likely to represent the same analyte are discussed. This procedure
can then be iterated for all pairs in X.
Spectrometric
Similarity
Mass spectra offer a wealth
of information, which facilitates comparison of two chromatographic
peaks m and n. Both m and n contain a mass spectrum, represented by a
vector of mass-to-charge ratio (m/z) values i and a vector of intensity values j. To assess the similarity, the algorithm first ranks both m(i,j) and n(i,j) on j, and
then extracts the m/z values of
the x most intense peaks. In this work, we mainly
used x = 30 as it provided a robust performance in
combination with our mass spectrometer. Of course, x can be altered to concur with the characteristics of the MS instrument
and the ionization method. Next, the ranked vectors mrank and nrank are linearly
compared based on the following criteria:Here, p is the precision
of the mass spectrometer (in our case 0.01 Da). If the element m(i) matches element n(i) within the precision limit, the combination
is given a score 1. Since xm/z values are compared, the maximum score is x. The relative score is calculated by dividing the score
by x and multiplication by 100 to obtain a similarity
percentage. We found x = 30 to provide the most robust
results and refer to this score as MS-30 (the similarity of the 30
most abundant peaks in mass spectra).In the event that the
relative score exceeds a preset value, in our case 75%, and no additional
pair within X(m,:) or X(:,n) exceeds this score [i.e., there are no multiple
options for either m(i) or n(i)], then the pair is considered to be
likely true.
Chromatographic Peak Similarity
In addition to spectrometric
information, there are also chromatographic features which can be
considered, such as the statistical moments of a peak. In this study,
the zeroth and third moments of peaks m and n were compared (i.e., peak area and vertical asymmetry).
The second moment, the variance, was also investigated, but was found
to reduce ability of the algorithm to reliably compare two peaks.While useful, statistical moments rely heavily on the type of mathematical
distribution that the peak represents and whether or not the peak
is pure. Indeed, an overlapping neighbor can significantly influence
the statistical moments. Nevertheless, in case of multiple isomers
present in the chromatogram, the mass spectrum will be similar, yet
the statistical moments and relative retention time are not necessarily.
As a result, it was opted to exclusively assess the statistical moments
for logical pairs in the event that the spectroscopic similarity yielded
inconclusive results.In the event that the statistical moments
of two peaks are similar,
the logical pair is now marked as likely pair and pooled with the
likely pairs from the Spectrometric Similarity section. Rejected pairs are pooled with the residual pairs from
the Preparation of the Data section.
Evaluation
To evaluate whether a likely pair can be
verified and accepted, the algorithm checks a number of scenarios.
Evaluation of Initially Logical Paired Peaks
First,
a new but more accurate definition is established of the average relative
retention. For all likely pairs from the comparison block, the retention
time in chromatogram m, tR,, is plotted against the ratio of retention times tR,/tR, (see Supporting Information Section S-2 for an example). A second-degree
polynomial is fitted through the points, which can be used to calculate
the likely retention time in chromatogram n, tR, for any tR,.Next, the extracted ion chromatogram
(XIC) for the most abundant m/z of
the two paired peaks is created. For both chromatograms, the XIC is
scanned for local maxima and the retention time of the apex on the
total ion-current chromatogram (TIC) is compared with the local maximum
found in the XIC. If maxima on the TIC and XIC match, then the algorithm
concludes that the most abundant m/z is at its local maximum at the identical location of the likely
pair. The algorithm now compares the areas of the XIC peak in chromatograms m and n using a simple trapezoidal numerical
integration function. If the similarity of the areas is not satisfactory,
the pair is rejected.One risk associated with the comparison
of mass spectra is that
a strongly overlapping neighbor peak can significantly influence the
mass spectrum of the peak of interest (POI). In the event of partial
or complete coelution, a large number of the abundant m/z values will be present in the mass spectrum of
the POI and the algorithm may incorrectly conclude that two peaks
represent the same analyte when they do not.The algorithm thus
verifies whether the most abundant m/z value of the POI in m matches
with that of n. In the event that this is not the
case, the XIC is scanned for nearby peaks of the same mass. To avoid
incorrect pairing of potentially existing isomers with the POI, the
scanning domain is determined by the earlier established relative
retention relation with a window of 5% deviation.Moreover,
the XIC for the alternative mass is established for both
chromatograms and cross-referenced. If no satisfactory combination
is found, the likely pair is rejected. If both m/z values are found in both chromatograms, the clearly coeluting
peak is split by the algorithm into two paired peaks. All combinations
rejected during the evaluation are now pooled with the residual combinations
for further evaluation.
Evaluation of Residual Peaks
Before
addressing the
further evaluation of residual peaks, it is good to note that all
steps taken thus far aimed to significantly reduce the number of combinations
for evaluation by the algorithm. More importantly, it should now be
evident that, if a combination was incorrectly included within the
pool of logical combinations, the evaluation should automatically
have corrected this. In any case, the total number of remaining combinations
possible should be significantly reduced, as is illustrated in Figure D. Here, the gray
bins represent combinations that are no longer likely, because one
of the two peaks has already been paired with another peak. The white
bins represent the remaining possible combinations, all of which will
be compared by the algorithm through the procedures explained in the Comparison section and evaluated as explained
in the Evaluation of Initially Logical Paired Peaks section.The residual combinations all go through MS-1 comparison.
For each unpaired candidate in chromatogram m, the
algorithm scans the XIC for the nearest unpaired peak in chromatogram n, within a range of 10%, or vice versa. If found, the algorithm
cross-references its own peak-detection database (Peak Detection section) to see whether the TIC peak was already
detected and/or paired. In the event of no conflict, the peaks are
paired.
Isomers
In the event that, during the evaluation steps
described in the previous section, multiple peaks of the exact identical m/z value are detected/paired, then the
algorithm is programmed to treat this as a case of isomers.In this case, the XIC of the m/z of interest is extracted for both chromatograms, and they are treated
as two individual new chromatograms that will be subjected to peak
tracking. In essence, this means that all already paired peaks of
the same m/z are unpaired and paired
again. This is a practical solution in the event that the chromatogram
is populated with multiple peaks of the same m/z, in which case the algorithm will struggle to pair partially
coeluting isomers.
Evaluation through Retention Curves
One advantage when
tracking peaks across chromatograms used for gradient scanning is
that the results are immediately used for retention prediction. Typically,
the slopes of the two most extreme scanning gradients differ by a
factor of 3.[10] The retention times of peaks
that are manually or algorithmically tracked are combined across chromatograms
so that a retention model may be fitted. There are a number of statistical
tools to evaluate the ability of the model to describe the data, such
as the Akaike information criterion,[18] which
can be reliably applied if multiple chromatograms are combined simultaneously.
Furthermore, logical indicators such as the slope of the obtained
retention curve of a compound can also provide evidence as to the
likelihood of realistic peak tracking. Supporting Information Section S-6 clarifies how model evaluation can
be used to filter wrongly paired peaks.
Experimental Section
Instruments
The LC system used for LC–MS analysis
comprised an Agilent 1290 series binary pump (G4220A), an Agilent
1260 Infinity degasser (G1322A), an Agilent Infinity 1290 diode-array
detector (DAD, G4212A) equipped with an Agilent Max-Light cartridge
cell (G4212-6008, V0 = 1.0 μL),
and an Agilent 1100 series autosampler (G1313A). The injection volume
was set to 5 μL, and the DAD data (used for manual verification
of the automatic pairing results) were recorded at several wavelengths
at an acquisition rate of 160 Hz. The system was controlled by OpenLAB
CDS Chemstation edition rev. C.01.04 [35] software. For the analysis
of the dyes, the flow was split using a stainless-steel tee-connection
(P/N U-428, IDEX, Lake Forest, IL, U.S.A.), with a 500 mm × 0.25
mm i.d. tubing to the DAD and 500 mm × 0.12 mm i.d. to the Bruker
MicroTOF-Q mass spectrometer (Bruker Daltonik, Bremen, Germany). For
the HILIC analyses, 100% of the flow was sent to the MS. The MS was
equipped with an electrospray ionization source and configured to
run in negative mode at an acquisition rate of 4 Hz. The system was
controlled with Compass 1.3 software for MicroTOF-SR1 (MicroTOF control
version 3.0, Build 53, Bruker). For the reversed-phase LC studies
an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HT (959941-902,
50 mm × 4.6 mm, 1.8 μm particles, 98 Å pore size)
column was used, whereas a Waters Acquity BEHamide (150 mm ×
2.1 mm i.d., 1.7 μm particles, 130 Å pore size) column
was used for the HILIC study.
Chemicals
Acetonitrile
(LC–MS grade) was obtained
from Biosolve (Valkenswaard, The Netherlands); deionized water (LiChrosolv,
LC–MS grade) was procured from Merck (Darmstadt, Germany).
Triethylamine (≥99.5%), dimethyl sulfoxide (DMSO, ≥
99%), ammonium formate (reagent grade), and formic acid (≥96%)
were obtained from Sigma-Aldrich (Darmstadt, Germany). The light-induced,
degraded dyestuffs eosine and alizarine were obtained from the reference
collection of the Cultural Heritage Agency of The Netherlands (RCE,
Amsterdam, The Netherlands).
Analytical Methods
For the dye mixtures,
the LC separation
was based on our earlier developed fast ion-pair method. A buffer
was prepared, containing triethylamine (5 mM) in water with formic
acid added to achieve a pH of 3. Mobile phase A consisted of buffer/acetonitrile
95:5 [v/v], and B consisted of buffer/acetonitrile 5:95 [v/v]. The
flow rate was 1.85 mL/min. The gradient used was as follows: 0–0.25
min, isocratic at 100% A followed by a min linear gradient to 100%
B in 6, 12, or 18 min, maintained at 100% B for 0.5 min, and finally
a 0.75 min linear gradient to 100% A. In the above program, the length
of the gradient time, tG, was varied to
obtain the data needed for gradient scanning. The MS ion source operating
conditions were the following: end plate offset −500 V; capillary
voltage 3800 V (positive mode −4400 V); nebulizer gas pressure
2.0 bar; drying gas flow 10 L·min–1; source
temperature 250 °C. The injection volume was 5 μL.
Data Processing
The entire algorithm was written using
MATLAB 2017a (Mathworks, Natick, MA, U.S.A.) for the in-house developed
PIOTR program.[10] All data were processed
using PIOTR. Raw MS data was converted into mzXML format by CompassXport
3.0.13.1 (Bruker Daltonik, Bremen, Germany).
Results and Discussion
Application
to Analysis of Alizarin by Ion-Pair Reversed-Phase
LC
While the algorithm was tested on a large variety of LC
analyses of simple standard mixtures, more challenging samples were
required to study the robustness of the algorithm to common practical
issues in the separations. The first case presented in this paper
is a sample of alizarin in DMSO which was subjected to focused light
at 254 nm for 5.5 h. Two chromatograms were recorded using scanning
gradients from 100% A to 100% B with a gradient duration (tG) of 6 and 18 min. The TIC chromatograms can
be seen in Figure , parts A and B, respectively (see Supporting Information Section S-4 for more extensive data). The purple
dots reflect the detected peaks that were not excluded due to a lack
of peak prominence or being identified as a spurious peak (see Supporting
Information Section S-3 for a completely
unfiltered chromatogram with all detected peaks). The green numbers
depict the coupled peaks.
Figure 4
(A and B) Gradient-scanning LC–MS TIC
chromatograms of light-degraded
alizarin using a gradient time of (A) 6 and (B) 18 min. Detected,
filtered peaks are depicted with purple markers. The green numbers
reflect identified peak pairs. (C) The relative retention times of
the matched peak pairs in chromatograms A and B, with the latter set
to 100%. (D) Plot of the similarity scores based on statistical moments
(■), mass spectra (▲), and the combined score (●)
for each peak pair. MS-30 = similarity between the 30 most abundant
peaks on the MS spectra (see the Spectrometric
Similarity section). The yellow marked peaks are discussed
further in the text.
(A and B) Gradient-scanning LC–MS TIC
chromatograms of light-degraded
alizarin using a gradient time of (A) 6 and (B) 18 min. Detected,
filtered peaks are depicted with purple markers. The green numbers
reflect identified peak pairs. (C) The relative retention times of
the matched peak pairs in chromatograms A and B, with the latter set
to 100%. (D) Plot of the similarity scores based on statistical moments
(■), mass spectra (▲), and the combined score (●)
for each peak pair. MS-30 = similarity between the 30 most abundant
peaks on the MS spectra (see the Spectrometric
Similarity section). The yellow marked peaks are discussed
further in the text.In Figure C the
relative retention times from the two chromatograms are plotted. The
retention times of the first loaded chromatogram are set to 100%,
and the retention times of the other chromatogram(s) are plotted relative
to this value. In our software we aim to give the end-user the possibility
of a complete overview of the data behind the calculations. Thus,
significant deviations in Figure C can attend the user to a possible (unexpected) shift
in elution order, or a wrongly paired set of peaks.Similarly, Figure D displays the different
scores that contribute to the overall score
per paired set of peaks to allow the end-user to quickly evaluate
the pairing performance. The usefulness of the statistical moments
becomes apparent for pairs 1 and 2. For these pairs, the constituting
chromatographic bands overlap in chromatogram A, which also impacts
the MS spectra of these peaks. This is reflected in a poor similarity
of the 30 most abundant peaks in both mass spectra (MS-30, see the Spectrometric Similarity section). Computationally,
the peaks can still easily be distinguished based on their statistical
moments, allowing the algorithm to correctly pair the peaks.Another issue is illustrated by the missed pair number 16 marked
with a yellow dot in Figure , parts A and B. These peaks had to be manually paired through
the user interface. Their relative retention and similarity scores
are marked in yellow in Figure , parts C and D. Visually the two peaks are clearly a match;
the similarity scores are not optimal, but the MS-30 exceeds the limit
of 75%. The algorithm reported that the pair had been accepted initially
but rejected as a result of the isomer evaluation (Isomers section).To detect chromatographic bands of
isomers in the XIC, the algorithm
applies a simple local-maxima search function. A relatively strict
(i.e., high) minimal prominence of the peak is used. This has the
advantage that the algorithm will ignore relatively high noise signals
at the particular m/z value. However,
if the threshold is wrongly chosen, the algorithm may find an unequal
number of isomer peaks in the two chromatograms. The latter will result
in rejection of the peak. As can be seen in Supporting Information Section S-5, three isomer bands are present in
the chromatogram. However, with one of the two gradients these peaks
nearly coeluted and the first peak was missed by the local-maxima
search. While an adjustment of the minimal prominence would be an
obvious solution, the correct threshold for finding the optimal (“true”)
number of pairs differs significantly from experiment to experiment.A third chromatogram was recorded using a gradient time of 12 min,
and the retention parameters were obtained for all analytes (see the Evaluation through Retention Curves section).
Using the retention parameters, the retention times of the third chromatogram
were predicted and compared with the experimental values. As shown
in Supporting Information Section S-6,
the average prediction error was 0.9%, which is similar to retention-modeling
experiments that use manual peak tracking.[9,19,20]
Application to Analysis of Eosin by Ion-Pair
Reversed-Phase
LC
Similar to alizarin, a sample of eosin dissolved in DMSO
was aged by UV light at 254 nm for 5.5 h. The resulting chromatograms,
relative retention plot, and similarly scores are shown in Figure . The algorithm was
generally found to perform well, pairing all visually found peaks.
Under the influence of light, eosin can lose up to four bromine atoms
(see Supporting Information Section S-9), leading to a number of isomers, which, if coeluting, pose a significant
challenge to the algorithm. Supporting Information Section S-7 illustrates a difficult case, which was correctly
resolved. However, in some other cases where the chromatographic separation
was also poor we observed wrong peak assignments. An example is shown
in Supporting Information Section S-8.
Similar to alizarin, retention parameters were fitted using the automatically
paired peaks and the retention times were predicted for a third chromatogram
not used to obtain the retention models. With most (partially coeluting)
isomers correctly paired, the overall performance of the algorithm
was deemed acceptable with an average prediction error 0.4% (Supporting
Information Section S-9).
Figure 5
(A and B) Gradient-scanning
LC–MS TIC chromatograms of light-degraded
eosin using gradient times of (A) 6 and (B) 18 min. Detected, filtered
peaks are indicated with purple markers; the green numbers reflect
identified peak pairs. (C) The relative retention times of the matched
peak pairs in chromatograms A and B, with the latter set to 100%.
(D) Plot of the similarity scores based on statistical moments (■),
mass spectra (▲), and the combined score (●) for each
peak pair. MS-30 = similarity between the 30 most abundant peaks on
the MS spectra (see the Spectrometric Similarity section).
(A and B) Gradient-scanning
LC–MS TIC chromatograms of light-degraded
eosin using gradient times of (A) 6 and (B) 18 min. Detected, filtered
peaks are indicated with purple markers; the green numbers reflect
identified peak pairs. (C) The relative retention times of the matched
peak pairs in chromatograms A and B, with the latter set to 100%.
(D) Plot of the similarity scores based on statistical moments (■),
mass spectra (▲), and the combined score (●) for each
peak pair. MS-30 = similarity between the 30 most abundant peaks on
the MS spectra (see the Spectrometric Similarity section).
Conclusions and Outlook
We have developed a peak-tracking algorithm for liquid chromatography
coupled with mass spectrometry to track peaks across chromatograms
obtained from gradient-scanning techniques and method-optimization
tools. The performance of the algorithm was demonstrated using two
different samples which included the presence of isomers. The automatically
tracked peaks and their consequently fitted retention parameters generally
yielded prediction errors of less than 1%. While the algorithm was
developed for use with gradient-scanning techniques (i.e., identical
sample, different mobile phase composition programs), it can also
be applied to chromatograms of different samples, provided that parts
of algorithm in the preparation block (Preparation
of the Data section), which use the relative retention to limit
the number of options so as to enhance the speed, are turned off.The robustness of the algorithm toward partially coeluting isomers,
especially when the separation is not equally good in all of the paired
chromatograms, may still be improved. Moreover, we are exploring possibilities
or the algorithm to correctly estimate a threshold value, which is
representative for the peaks on the chromatogram.Another expansion
is that is currently under investigation involves
using the similarity between UV–vis spectra to track peaks.
Unlike common reversed-phase behavior, the description of analyte
retention in HILIC may necessitate three-parameter retention models,
which require more than two scanning chromatograms. A specific goal
for the algorithm is thus the ability to be able to track peaks across
more than two chromatograms. In its current state, the algorithm supports
this, but more testing is required.Our ultimate goal is for
the algorithm to automatically pair peaks
across two-dimensional liquid chromatography experiments. Here, the
statistical moments of the peak in a second dimension may prove to
be of major significance.