Exposure to buffer solution alters tendon hydration and mechanics.

Babak N Safa1, Kyle D Meadows2, Spencer E Szczesny3, Dawn M Elliott4.   

Abstract

A buffer solution is often used to maintain tissue hydration during mechanical testing. The most commonly used buffer solution is a physiological concentration of phosphate buffered saline (PBS); however, PBS increases the tissue's water content and decreases its tensile stiffness. In addition, solutes from the buffer can diffuse into the tissue and interact with its structure and mechanics. These bathing solution effects can confound the outcome and interpretation of mechanical tests. Potential bathing solution artifacts, including solute diffusion, and their effect on mechanical properties, are not well understood. The objective of this study was to measure the effects of long-term exposure of rat tail tendon fascicles to several concentrations (0.9-25%) of NaCl, sucrose, polyethylene glycol (PEG), and SPEG (NaCl+PEG) solutions on water content, solute diffusion, and mechanical properties. We found that with an increase in solute concentration the apparent water content decreased for all solution types. Solutes diffused into the tissue for NaCl and sucrose, however, no solute diffusion was observed for PEG or SPEG. The mechanical properties changed for both NaCl solutions, in particular after long-term (8h) incubation the modulus and equilibrium stress decreased compared to short-term (15min) for 25% NaCl, and the cross sectional area increased for 0.9% NaCl. However, the mechanical properties were unchanged for both PEG and SPEG except for minor alterations in stress relaxation parameters. This study shows that NaCl and sucrose buffer solutions are not suitable for long-term mechanical tests. We therefore propose using PEG or SPEG as alternative buffer solutions that after long-term incubation can maintain tissue hydration without solute diffusion and produce a consistent mechanical response.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Buffer solution; Stress relaxation; Tendon; Tendon mechanics; Tension

Mesh:

Substances:

Year:  2017        PMID: 28720201      PMCID: PMC5659756          DOI: 10.1016/j.jbiomech.2017.06.045

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  34 in total

1.  Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and Failure.

Authors:  John M Peloquin; Michael H Santare; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

2.  Mechanical properties of rat tail tendon in relation to proximal-distal sampling position and age.

Authors:  C C Danielsen; T T Andreassen
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

3.  The intermolecular space of reconstituted collagen fibrils.

Authors:  E P Katz; S T Li
Journal:  J Mol Biol       Date:  1973-02-19       Impact factor: 5.469

4.  Swelling of the intervertebral disc in vitro.

Authors:  J P Urban; A Maroudas
Journal:  Connect Tissue Res       Date:  1981       Impact factor: 3.417

5.  Altering ligament water content affects ligament pre-stress and creep behaviour.

Authors:  G M Thornton; N G Shrive; C B Frank
Journal:  J Orthop Res       Date:  2001-09       Impact factor: 3.494

6.  Water potential of aqueous polyethylene glycol.

Authors:  A A Steuter
Journal:  Plant Physiol       Date:  1981-01       Impact factor: 8.340

7.  Contribution of glycosaminoglycans to viscoelastic tensile behavior of human ligament.

Authors:  Trevor J Lujan; Clayton J Underwood; Nathan T Jacobs; Jeffrey A Weiss
Journal:  J Appl Physiol (1985)       Date:  2008-12-12

8.  Glutaraldehyde cross-linking of tendon--mechanical effects at the level of the tendon fascicle and fibril.

Authors:  Philip Hansen; Tue Hassenkam; Rene Bruggebusch Svensson; Per Aagaard; Todd Trappe; Bjarki Thor Haraldsson; Michael Kjaer; Peter Magnusson
Journal:  Connect Tissue Res       Date:  2009       Impact factor: 3.417

9.  Relationship between solute transport properties and tissue morphology in human annulus fibrosus.

Authors:  Francesco Travascio; Alicia R Jackson; Mark D Brown; Wei Yong Gu
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

10.  Effect of dermatan sulfate glycosaminoglycans on the quasi-static material properties of the human medial collateral ligament.

Authors:  Trevor J Lujan; Clayton J Underwood; Heath B Henninger; Brent M Thompson; Jeffrey A Weiss
Journal:  J Orthop Res       Date:  2007-07       Impact factor: 3.494

View more
  11 in total

1.  Helical fibrillar microstructure of tendon using serial block-face scanning electron microscopy and a mechanical model for interfibrillar load transfer.

Authors:  Babak N Safa; John M Peloquin; Jessica R Natriello; Jeffrey L Caplan; Dawn M Elliott
Journal:  J R Soc Interface       Date:  2019-11-20       Impact factor: 4.118

2.  Evaluating Plastic Deformation and Damage as Potential Mechanisms for Tendon Inelasticity using a Reactive Modeling Framework.

Authors:  Babak Safa; Andrea Lee; Michael H Santare; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2019-04-20       Impact factor: 2.097

3.  Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling.

Authors:  Babak N Safa; Ellen T Bloom; Andrea H Lee; Michael H Santare; Dawn M Elliott
Journal:  J Biomech       Date:  2020-06-26       Impact factor: 2.712

4.  Structure, composition and fibril-reinforced poroviscoelastic properties of bovine knee ligaments and patellar tendon.

Authors:  Aapo Ristaniemi; Dristi Regmi; Diponkor Mondal; Jari Torniainen; Petri Tanska; Lauri Stenroth; Mikko A J Finnilä; Juha Töyräs; Rami K Korhonen
Journal:  J R Soc Interface       Date:  2021-01-27       Impact factor: 4.118

5.  Water-content related alterations in macro and micro scale tendon biomechanics.

Authors:  Pamela F Lozano; Mario Scholze; Carsten Babian; Holger Scheidt; Franziska Vielmuth; Jens Waschke; Benjamin Ondruschka; Niels Hammer
Journal:  Sci Rep       Date:  2019-05-27       Impact factor: 4.379

6.  Influences of sodium and glycosaminoglycans on skin oedema and the potential for ulceration: a finite-element approach.

Authors:  Wu Pan; Sara Roccabianca; Marc D Basson; Tamara Reid Bush
Journal:  R Soc Open Sci       Date:  2019-07-03       Impact factor: 2.963

7.  Regional Differences in the Glycosaminoglycan Role in Porcine Scleral Hydration and Mechanical Behavior.

Authors:  Mohammad Pachenari; Hamed Hatami-Marbini
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-03-01       Impact factor: 4.799

8.  Elastase treatment of tendon specifically impacts the mechanical properties of the interfascicular matrix.

Authors:  Marta S Godinho; Chavaunne T Thorpe; Steve E Greenwald; Hazel R C Screen
Journal:  Acta Biomater       Date:  2021-01-26       Impact factor: 8.947

9.  Tendon Multiscale Structure, Mechanics, and Damage Are Affected by Osmolarity of Bath Solution.

Authors:  Ellen T Bloom; Andrea H Lee; Dawn M Elliott
Journal:  Ann Biomed Eng       Date:  2020-10-30       Impact factor: 3.934

10.  Accumulation of collagen molecular unfolding is the mechanism of cyclic fatigue damage and failure in collagenous tissues.

Authors:  Jared L Zitnay; Gang Seob Jung; Allen H Lin; Zhao Qin; Yang Li; S Michael Yu; Markus J Buehler; Jeffrey A Weiss
Journal:  Sci Adv       Date:  2020-08-28       Impact factor: 14.957

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.