Tendon Multiscale Structure, Mechanics, and Damage Are Affected by Osmolarity of Bath Solution.

Ellen T Bloom1, Andrea H Lee1, Dawn M Elliott2.   

Abstract

One of the most common bath solutions used in musculoskeletal mechanical testing is phosphate buffered saline (PBS). In tendon, swelling induced by physiological PBS results in decreased tendon modulus and induces microstructural changes. It is critical to evaluate the multiscale mechanical behavior of tendon under swelling to interpret prior work and provide information to design future studies. We compared the effects of physiological PBS and 8% polyethylene glycol and saline bathing solutions on tendon multiscale tendon mechanics and damage as well as microstructure with TEM in order to understand the effect of swelling on tendon. At the tissue level, tendons in PBS had a lower modulus than SPEG samples. PBS samples also showed an increased amount of non-recoverable sliding, which is an analog for microscale damage. SPEG had a higher microscale to tissue-scale strain ratio, showing the fibrils experienced less strain attenuation. From the TEM data, we showed the fibril spacing of SPEG samples was more similar to fresh control than PBS. We concluded that swelling alters multiscale mechanics and damage in addition to tendon microstructure. Future mechanical testing should consider using SPEG as a bath solution with an osmotic pressure which preserves fresh tissue water content.

Entities:  

Keywords:  Buffer solution; Imaging; Multi-scale testing; TEM

Mesh:

Substances:

Year:  2020        PMID: 33128181      PMCID: PMC7954897          DOI: 10.1007/s10439-020-02649-z

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  3 in total

1.  Long-term histological analysis of innervation and macrophage infiltration in a mouse model of intervertebral disc injury-induced low back pain.

Authors:  Seunghwan Lee; Magali Millecamps; Daniel Z Foster; Laura S Stone
Journal:  J Orthop Res       Date:  2019-12-25       Impact factor: 3.494

2.  Exposure to buffer solution alters tendon hydration and mechanics.

Authors:  Babak N Safa; Kyle D Meadows; Spencer E Szczesny; Dawn M Elliott
Journal:  J Biomech       Date:  2017-07-06       Impact factor: 2.712

3.  Swelling of articular cartilage and other connective tissues: electromechanochemical forces.

Authors:  S R Eisenberg; A J Grodzinsky
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

  3 in total
  1 in total

1.  Rehydration of the Tendon Fascicle Bundles Using Simulated Body Fluid Ensures Stable Mechanical Properties of the Samples.

Authors:  Sylwia Dabrowska; Krzysztof Grabowski; Andrzej Mlyniec
Journal:  Materials (Basel)       Date:  2022-04-21       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.