Literature DB >> 17343278

Effect of dermatan sulfate glycosaminoglycans on the quasi-static material properties of the human medial collateral ligament.

Trevor J Lujan1, Clayton J Underwood, Heath B Henninger, Brent M Thompson, Jeffrey A Weiss.   

Abstract

The glycosaminoglycan of decorin, dermatan sulfate (DS), has been suggested to contribute to the mechanical properties of soft connective tissues such as ligaments and tendons. This study investigated the mechanical function of DS in human medial collateral ligaments (MCL) using nondestructive shear and tensile material tests performed before and after targeted removal of DS with chondroitinase B (ChB). The quasi-static elastic material properties of human MCL were unchanged after DS removal. At peak deformation, tensile and shear stresses in ChB treated tissue were within 0.5% (p>0.70) and 2.0% (p>0.30) of pre-treatment values, respectively. From pre- to post-ChB treatment under tensile loading, the tensile tangent modulus went from 242+/-64 to 233+/-57 MPa (p=0.44), and tissue strain at peak deformation went from 4.3+/-0.3% to 4.4+/-0.3% (p=0.54). Tissue hysteresis was unaffected by DS removal for both tensile and shear loading. Biochemical analysis confirmed that 90% of DS was removed by ChB treatment when compared to control samples, and transmission electron microscopy (TEM) imaging further verified the degradation of DS by showing an 88% reduction (p<.001) of sulfated glycosaminoglycans in ChB treated tissue. These results demonstrate that DS in mature knee MCL tissue does not resist tensile or shear deformation under quasi-static loading conditions, challenging the theory that decorin proteoglycans contribute to the elastic material behavior of ligament. Copyright (c) 2007 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17343278     DOI: 10.1002/jor.20351

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  54 in total

1.  A novel bioreactor for the dynamic stimulation and mechanical evaluation of multiple tissue-engineered constructs.

Authors:  Trevor J Lujan; Kyle M Wirtz; Chelsea S Bahney; Steven M Madey; Brian Johnstone; Michael Bottlang
Journal:  Tissue Eng Part C Methods       Date:  2010-12-06       Impact factor: 3.056

2.  Micromechanical poroelastic finite element and shear-lag models of tendon predict large strain dependent Poisson's ratios and fluid expulsion under tensile loading.

Authors:  Hossein Ahmadzadeh; Benjamin R Freedman; Brianne K Connizzo; Louis J Soslowsky; Vivek B Shenoy
Journal:  Acta Biomater       Date:  2015-04-29       Impact factor: 8.947

3.  Incorporation of a decorin biomimetic enhances the mechanical properties of electrochemically aligned collagen threads.

Authors:  Vipuil Kishore; John E Paderi; Anna Akkus; Katie M Smith; Dave Balachandran; Stephen Beaudoin; Alyssa Panitch; Ozan Akkus
Journal:  Acta Biomater       Date:  2011-02-26       Impact factor: 8.947

4.  Collagen fibre arrangement and functional crimping pattern of the medial collateral ligament in the rat knee.

Authors:  Marco Franchi; Marilisa Quaranta; Maria Macciocca; Luisa Leonardi; Vittoria Ottani; Paolo Bianchini; Alberto Diaspro; Alessandro Ruggeri
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02-25       Impact factor: 4.342

5.  Collagen fibre and fibril ultrastructural arrangement of the superficial medial collateral ligament in the human knee.

Authors:  Stefano Zaffagnini; Giulio Maria Marcheggiani Muccioli; Marco Franchi; Beatrice Bacchelli; Alberto Grassi; Patrizia Agati; Marilisa Quaranta; Maurilio Marcacci; Viviana De Pasquale
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

6.  Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles.

Authors:  Spencer E Szczesny; Dawn M Elliott
Journal:  J Mech Behav Biomed Mater       Date:  2014-09-16

7.  Collagen fibril morphology and mechanical properties of the Achilles tendon in two inbred mouse strains.

Authors:  S Rigozzi; R Müller; J G Snedeker
Journal:  J Anat       Date:  2010-03-23       Impact factor: 2.610

8.  Exposure to buffer solution alters tendon hydration and mechanics.

Authors:  Babak N Safa; Kyle D Meadows; Spencer E Szczesny; Dawn M Elliott
Journal:  J Biomech       Date:  2017-07-06       Impact factor: 2.712

9.  Contribution of glycosaminoglycans to viscoelastic tensile behavior of human ligament.

Authors:  Trevor J Lujan; Clayton J Underwood; Nathan T Jacobs; Jeffrey A Weiss
Journal:  J Appl Physiol (1985)       Date:  2008-12-12

10.  Ring-Mesh Model of Proteoglycan Glycosaminoglycan Chains in Tendon based on Three-dimensional Reconstruction by Focused Ion Beam Scanning Electron Microscopy.

Authors:  Takafumi Watanabe; Kiyokazu Kametani; Yoh-Ichi Koyama; Daisuke Suzuki; Yasutada Imamura; Kazushige Takehana; Kohzy Hiramatsu
Journal:  J Biol Chem       Date:  2016-09-13       Impact factor: 5.157

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.