Literature DB >> 28708200

Periacetabular bone densitometry after total hip arthroplasty with highly porous titanium cups: a 2-year follow-up prospective study.

Leo Massari1, Alessandro Bistolfi2, Pier Paolo Grillo3, Alda Borré4, Gaetano Gigliofiorito1, Carlotta Pari1, Andrea Francescotto5, Piermario Tosco3, Davide Deledda2, Laura Ravera2, Araldo Causero5.   

Abstract

INTRODUCTION: Trabecular Titanium is an advanced cellular solid structure, composed of regular multiplanar hexagonal interconnected cells that mimic the morphology of the trabecular bone. This biomaterial demonstrated improved mechanical properties and enhanced osteoinduction and osteoconduction in several in vitro and in vivo studies. The aim of this study was to assess Trabecular Titanium osseointegration by measuring periacetabular changes in bone mineral density (BMD) with dual-emission X-ray absorptiometry (DEXA).
METHODS: 89 patients (91 hips) underwent primary total hip arthroplasty (THA) with acetabular Trabecular Titanium cups. Clinical (Harris Hip Score (HHS), SF-36) and radiographic assessment were performed preoperatively, and postoperatively at 7 days and at 3, 6, 12 and 24 months. DEXA analysis was performed only postoperatively, using the BMD values measured at 7 days as baselines.
RESULTS: After an initial decrease from baseline to 6 months, BMD increased and progressively stabilised in all 3 regions of interest (ROIs). Median (IQR) HHS and SF-36 increased from 48 (39-62) and 49 (37-62) preoperatively to 99 (96-100) and 86 (79-92) at 24 months, indicating a considerable improvement in terms of pain relief, functional recovery and quality of life. BMD patterns and radiographic evaluation showed evident signs of periacetabular bone remodelling and osseointegration; all cups were stable at the final follow-up without radiolucent lines, loosening or osteolysis. No revisions were performed.
CONCLUSIONS: After an initial reduction in periacetabular BMD, all 3 ROIs exhibited stabilisation or slight recovery. Although clinical outcomes and functional recovery proved satisfactory, longer follow-ups are necessary to assess this cup long-term survivorship.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28708200     DOI: 10.5301/hipint.5000509

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  6 in total

1.  Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty.

Authors:  Francesco Castagnini; Barbara Bordini; Makiko Yorifuji; Federico Giardina; Simone Natali; Francesco Pardo; Francesco Traina
Journal:  Med Princ Pract       Date:  2019-05-13       Impact factor: 1.927

2.  A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients.

Authors:  Xiao Geng; Yang Li; Feng Li; Xinguang Wang; Ke Zhang; Zhongjun Liu; Hua Tian
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

3.  Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.

Authors:  Kazuki Oishi; Yuji Yamamoto; Yoshifumi Harada; Ryo Inoue; Eiji Sasaki; Yasuyuki Ishibashi
Journal:  J Orthop Surg Res       Date:  2021-04-15       Impact factor: 2.359

4.  Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis.

Authors:  Amanda D Klaassen; Elisabeth A Schäffer; Nienke W Willigenburg; Loes W A H Van Beers; Vanessa A B Scholtes; Victor P M Van der Hulst; Lennard A Koster; Bart L Kaptein; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2022-04-28       Impact factor: 3.925

5.  Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study.

Authors:  Conrad Anderl; Georg Mattiassich; Reinhold Ortmaier; Martin Steinmair; Josef Hochreiter
Journal:  BMC Musculoskelet Disord       Date:  2020-10-06       Impact factor: 2.362

Review 6.  Off-the-shelf 3D printed titanium cups in primary total hip arthroplasty.

Authors:  Francesco Castagnini; Filippo Caternicchia; Federico Biondi; Claudio Masetti; Cesare Faldini; Francesco Traina
Journal:  World J Orthop       Date:  2021-06-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.