Literature DB >> 28697529

Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

Timo Julian Schwarz1, Markus Weber1, Christian Dornia2, Michael Worlicek1, Tobias Renkawitz1, Joachim Grifka1, Benjamin Craiovan1.   

Abstract

Purpose Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points  · Pelvic tilt and rotation influence cup orientation after THA. · Cup anteversion and inclination should be referenced to the pelvis. · Radiological measurement errors of cup position may be reduced by mathematical concepts. Citation Format · Schwarz TJ, Weber M, Dornia C et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Fortschr Röntgenstr 2017; 189: 864 - 873. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2017        PMID: 28697529     DOI: 10.1055/s-0043-110012

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  9 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

2.  Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Int Orthop       Date:  2018-02-17       Impact factor: 3.075

3.  Assessment of pelvic tilt in anteroposterior radiographs by means of tilt ratios.

Authors:  T Schwarz; A Benditz; H-R Springorum; J Matussek; G Heers; M Weber; T Renkawitz; J Grifka; B Craiovan
Journal:  Arch Orthop Trauma Surg       Date:  2018-04-12       Impact factor: 3.067

Review 4.  [Discrepancy between radiographic and true cup position after total hip arthroplasty : Are we interpreting our radiographic quality indicators correctly? Video article].

Authors:  T J Schwarz; M Weber; T Renkawitz; F Greimel; F Leiss; J Grifka; J Schaumburger
Journal:  Orthopade       Date:  2020-03       Impact factor: 1.087

5.  The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Guo-Fei Sun; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Biol Eng Comput       Date:  2019-09-09       Impact factor: 2.602

6.  The effect of pelvic ring rotation and tilt on the radiographic teardrop distance: an important consideration in the assessment of dynamic displacement on stress radiographs.

Authors:  Nicholas J Tucker; Bryan L Scott; Austin Heare; Stephen C Stacey; Cyril Mauffrey; Joshua A Parry
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-09-01

7.  A Novel Method for Correcting Pelvic Tilt on Anteroposterior Pelvic Radiographs.

Authors:  Jeffrey M Muir; John Vincent; Joseph Schipper; Varsha D Gobin; Meinusha Govindarajan; Karlina Fiaes; Jonathan Vigdorchik
Journal:  Cureus       Date:  2019-12-02

8.  3D simulation of radiographic projections to test and reduce the effect of pelvic tilt on the accuracy of cross-table lateral radiography.

Authors:  Jie Xu; Baohua Su; Wenhui Zhang; Hao Sun; Deng Li; Zhiqing Cai; Meiyi Chen; Meiling Qiu; Ruofan Ma
Journal:  BMC Musculoskelet Disord       Date:  2020-12-14       Impact factor: 2.362

9.  Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure.

Authors:  Timo J Schwarz; Günther Maderbacher; Franziska Leiss; Joachim Grifka; G Heers; J Matussek
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-24       Impact factor: 3.067

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.