An IR Sensor Based Smart System to Approximate Core Body Temperature.

Partha Pratim Ray1.   

Abstract

Herein demonstrated experiment studies two methods, namely convection and body resistance, to approximate human core body temperature. The proposed system is highly energy efficient that consumes only 165 mW power and runs on 5 VDC source. The implemented solution employs an IR thermographic sensor of industry grade along with AT Mega 328 breakout board. Ordinarily, the IR sensor is placed 1.5-30 cm away from human forehead (i.e., non-invasive) and measured the raw data in terms of skin and ambient temperature which is then converted using appropriate approximation formula to find out core body temperature. The raw data is plotted, visualized, and stored instantaneously in a local machine by means of two tools such as Makerplot, and JAVA-JAR. The test is performed when human object is in complete rest and after 10 min of walk. Achieved results are compared with the CoreTemp CM-210 sensor (by Terumo, Japan) which is calculated to be 0.7 °F different from the average value of BCT, obtained by the proposed IR sensor system. Upon a slight modification, the presented model can be connected with a remotely placed Internet of Things cloud service, which may be useful to inform and predict the user's core body temperature through a probabilistic view. It is also comprehended that such system can be useful as wearable device to be worn on at the hat attachable way.

Entities:  

Keywords:  Core body Temperature; Distant Measurement; Infra Red Sensor

Mesh:

Year:  2017        PMID: 28695440     DOI: 10.1007/s10916-017-0770-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  13 in total

Review 1.  Deep temperature monitoring using a zero-heat-flow method.

Authors:  Michiaki Yamakage; Akiyoshi Namiki
Journal:  J Anesth       Date:  2003       Impact factor: 2.078

2.  Prediction of Core Body Temperature from Multiple Variables.

Authors:  Victoria L Richmond; Sarah Davey; Katy Griggs; George Havenith
Journal:  Ann Occup Hyg       Date:  2015-08-12

3.  Estimation of human core temperature from sequential heart rate observations.

Authors:  Mark J Buller; William J Tharion; Samuel N Cheuvront; Scott J Montain; Robert W Kenefick; John Castellani; William A Latzka; Warren S Roberts; Mark Richter; Odest Chadwicke Jenkins; Reed W Hoyt
Journal:  Physiol Meas       Date:  2013-06-19       Impact factor: 2.833

4.  Insulated skin temperature as a measure of core body temperature for individuals wearing CBRN protective clothing.

Authors:  V L Richmond; D M Wilkinson; S D Blacker; F E Horner; J Carter; G Havenith; M P Rayson
Journal:  Physiol Meas       Date:  2013-10-22       Impact factor: 2.833

5.  Development of a new method for the noninvasive measurement of deep body temperature without a heater.

Authors:  Kei-Ichiro Kitamura; Xin Zhu; Wenxi Chen; Tetsu Nemoto
Journal:  Med Eng Phys       Date:  2009-11-10       Impact factor: 2.242

6.  Hydration and thermoregulation during a half-ironman performed in tropical climate.

Authors:  Michelle Baillot; Olivier Hue
Journal:  J Sports Sci Med       Date:  2015-05-08       Impact factor: 2.988

7.  Characterization of ultradian and circadian rhythms of core body temperature based on wavelet analysis.

Authors:  Toshiyo Tamura; Kei-Ichiro Kitamura; Tetsu Nemoto; Shigehiko Kanaya
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

8.  A Wearable Thermometry for Core Body Temperature Measurement and Its Experimental Verification.

Authors:  Ming Huang; Toshiyo Tamura; Zunyi Tang; Wenxi Chen; Shigehiko Kanaya
Journal:  IEEE J Biomed Health Inform       Date:  2016-02-25       Impact factor: 5.772

9.  Non-invasive continuous core temperature measurement by zero heat flux.

Authors:  L P J Teunissen; J Klewer; A de Haan; J J de Koning; H A M Daanen
Journal:  Physiol Meas       Date:  2011-03-28       Impact factor: 2.833

10.  Telemetry pill measurement of core temperature in humans during active heating and cooling.

Authors:  C O'Brien; R W Hoyt; M J Buller; J W Castellani; A J Young
Journal:  Med Sci Sports Exerc       Date:  1998-03       Impact factor: 5.411

View more
  2 in total

Review 1.  A Systematic Review of Wearable Systems for Cancer Detection: Current State and Challenges.

Authors:  Partha Pratim Ray; Dinesh Dash; Debashis De
Journal:  J Med Syst       Date:  2017-10-02       Impact factor: 4.460

2.  Measurement of Core Body Temperature Using Graphene-Inked Infrared Thermopile Sensor.

Authors:  Jorge S Chaglla E; Numan Celik; Wamadeva Balachandran
Journal:  Sensors (Basel)       Date:  2018-10-03       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.