| Literature DB >> 28693493 |
M Smiljanic1, M Kaase2,3, P Ahmad-Nejad1, B Ghebremedhin4.
Abstract
BACKGROUND: Carbapenemase-producing gram-negative bacteria are increasing globally and have been associated with outbreaks in hospital settings. Thus, the accurate detection of these bacteria in infections is mandatory for administering the adequate therapy and infection control measures. This study aimed to establish and evaluate a multiplex real-time PCR assay for the simultaneous detection of carbapenemase gene variants in gram-negative rods and to compare the performance with a commercial RT-PCR assay (Check-Direct CPE).Entities:
Keywords: Acinetobacter baumannii; Carbapenemases; MDR gram-negative bacteria; RT-PCR
Mesh:
Substances:
Year: 2017 PMID: 28693493 PMCID: PMC5504714 DOI: 10.1186/s12941-017-0223-z
Source DB: PubMed Journal: Ann Clin Microbiol Antimicrob ISSN: 1476-0711 Impact factor: 3.944
Primer and probe sequences for the in-house RT-PCR assay
| Gene | Primer pairs | Product size, bp | Probe |
|---|---|---|---|
|
| for-GCGATACCACGTTCCGTCTG | 183 | 6FAM-AGCGGCAGCAGTTTGTTGATTG–BBQ |
|
| for-TTTGGCGATCTGGTTTTCCG | 101 | LC610-AGACATTCGGTGCGAGCTGGC–BBQ |
|
| for-CGCGACGTATCGGTCTTGAT | 162 | HEX-ACGTATTGGTTTCGGTAATGCTGA–BBQ |
|
| for-GGCACGTATGAGCAAGATGC | 182 | a |
|
| for-CCGAGTGGTGAGTATCCGAC | 337 | Cy5-CGCTGTATCAATCAAAAGCAACTCATCA–BBQ |
aThe melting-curve analysis for the OXA gene variants was performed with the OXA-48 primer. For the multiplex RT-PCR analysis a Light Mix Modular from TIB MOLBIOL Syntheselabor GmbH Berlin was used for OXA-48
Fig. 1Comparison of the in-house PCR assay and the Check-Direct CPE assay for the identification of carbapenemase-producing isolates (n = 116 isolates)
Fig. 2Melting-curve analysis of OXA-23-like and OXA-48-like gene variants. The carbapenemase genes were amplified by SYBR green multiplex PCR mix with OXA-23-like and OXA-48-like primer followed by melt curve analysis. The melting-curve was visualised at the wavelength channel of 475/520 nm. The melting peak for OXA-23-like was observed between 80.6 and 80.9 °C and for OXA-48-like between 83.2 and 83.3 °C
Detection of carbapenemase genes directly from positive blood culture vials by use of the in-house multiplex RT-PCR (n = 58)
| Species | OXA23-/48-like ( | NDM ( | VIM ( | KPC ( |
|---|---|---|---|---|
|
| 18a | 2a | ||
|
| 1 | 1 | ||
|
| 1 | |||
|
| 2 | |||
|
| 2 | 4 | 2 | |
|
| 1 | 1 | ||
|
| 5 | 4 | 1 | 11 |
|
| 4 | |||
| Detected by in-house RT-PCR | 21 | 11 | 9 | 13 |
a2 isolates carrying bla OXA-23-like and bla NDM-1/-6