OBJECTIVE: To investigate the value of application of low-dose and optimized length CT scan on puncture results, complications and patients' radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules (PTNB).Entities:
Keywords: CT guided; Low dose; Lung biopsy; Optimized scan; Radiation dose
Year: 2021 PMID: 34805963 PMCID: PMC8562293 DOI: 10.1016/j.jimed.2021.05.005
Source DB: PubMed Journal: J Interv Med ISSN: 2590-0293
Comparison of basic information of the three groups of patients.
| basic information | Conventional group | optimized length group | Low-dose optimized length group | Con/Opti | Opti/Low |
|---|---|---|---|---|---|
| P | P | ||||
| Gender(M/F) | 49/25 | 42/30 | 50/35 | 0.326 | 0.950 |
| Age(year) | 58.54 ± 12.24 | 59.18 ± 10.97 | 57.31 ± 11.67 | 0.609 | 0.245 |
| Weight(kg) | 61.77 ± 9.88 | 60.91 ± 10.09 | 59.08 ± 10.20 | 0.507 | 0.159 |
| Height (cm) | 165.31 ± 7.48 | 163.40 ± 7.93 | 162.88 ± 8.12 | 0.154 | 0.592 |
| BMI (kg/m2) | 22.56 ± 3.05 | 22.77 ± 3.08 | 22.21 ± 3.07 | 0.823 | 0.172 |
Comparison of the information of the three groups of patients during puncture.
| Intraoperative condition | Conventional group | optimized length group | Low-dose optimized length group | Con/ Opti | Opti/Low |
|---|---|---|---|---|---|
| P | P | ||||
| Biopsy needle (BARD/BD/ARGON) | 34/32/8 | 35/27/10 | 35/26/24 | 0.729 | 0.093 |
| Position (supine/prone) | 34/40 | 38/34 | 52/33 | 0.409 | 0.289 |
| Lesion location (right upper/middle/lower/left upper/lower) | 19/8/22/10/15 | 21/7/13/13/18 | 24/5/14/27/15 | 0.538 | 0.320 |
| Lesion size(cm) | 3.81 ± 2.38 | 3.19 ± 1.41 | 3.73 ± 1.87 | 0.229 | 0.094 |
| Puncture depth (cm) | 6.20 ± 1.94 | 6.27 ± 1.78 | 6.04 ± 1.75 | 0.474 | 0.363 |
| Distance across lung (cm) | 2.05 ± 1.98 | 2.23 ± 1.48 | 1.86 ± 1.54 | 0.196 | 0.122 |
| Number of adjustments | 2.89 ± 1.79 | 2.72 ± 1.53 | 2.59 ± 1.54 | 0.800 | 0.467 |
| Number of scans | 6.18 ± 2.48 | 5.78 ± 1.87 | 5.53 ± 1.74 | 0.684 | 0.345 |
| Bleeding (present vs absent) | 67/7 | 62/10 | 71/14 | 0.404 | 0.429 |
| Pneumothorax (present vs absent) | 64/10 | 57/15 | 73/12 | 0.240 | 0.404 |
| Puncture results (positive/suspicious/negative) | 59/6/9 | 58/3/11 | 75/1/9 | 0.554 | 0.315 |
Note: A positive in the puncture result indicates a confirmed malignant tumor, a suspected malignant tumor is not excluded, and a negative result indicates a non-malignant tumor.
Fig. 1A and C are pictures during CT guidance before and after puncture in the optimized length group, B and D are during CT guidance before and after puncture in the low-dose optimization length group. Both groups of pictures can clearly show the puncture needle and the lesion. The relationship of normal lung structure can also be clearly shown for postoperative review for identification of potential complications, such as needle bleeding.
Fig. 2A-D showed that the quality of CT pictures in low-dose optimization length group meet the demand of biopsy for lung lesions in different lobes and patients in different position.
Fig. 3Comparison of the distribution of DLP among the three groups in terms of preoperative positioning, intraoperative guidance and postoperative review.
Comparison of radiation dose and operation time among the three groups.
| Dose parameters | Conventional group | optimized length group | Low-dose optimized length group | Con/ Opti | Opti/Low |
|---|---|---|---|---|---|
| P | P | ||||
| positioning DLP(mGy·cm) | 312.4 ± 143.9 | 287.5 ± 130.1 | 33.87 ± 11.99 | 0.274 | <0.001 |
| guided DLP(mGy·cm) | 294.3 ± 259.4 | 185.3 ± 157.4 | 21.34 ± 15.10 | 0.003 | <0.001 |
| review DLP(mGy·cm) | 241.7 ± 197.2 | 220.2 ± 141.3 | 27.10 ± 14.55 | 0.451 | <0.001 |
| Total mAs | 6211 ± 3043 | 5122 ± 2111 | 1070.6 ± 306.7 | 0.013 | <0.001 |
| Average CTDIvol(mGy) | 9.79 ± 3.75 | 9.44 ± 3.04 | 1.33 ± 0.38 | 0.531 | <0.001 |
| ED(mSv) | 11.95 ± 5.86 | 9.77 ± 4.07 | 1.23 ± 0.41 | 0.010 | <0.001 |
| Operation duration(min) | 25.85 ± 8.95 | 22.40 ± 7.45 | 21.42 ± 7.91 | 0.021 | 0.214 |
binary logistic regression analysis of influencing factors of radiation dose in low dose optimized length group.
| Variable parameter | Standard error | Wald | P | Exp(B) | 95% CI of EXP(B) | |
|---|---|---|---|---|---|---|
| Lower | Upper | |||||
| Weight(kg) | 0.029 | 11.451 | 0.001 | 1.103 | 1.042 | 1.167 |
| BMI (kg/m2) | 0.093 | 11.076 | 0.001 | 1.365 | 1.136 | 1.639 |
| Puncture depth (cm) | 0.154 | 10.507 | 0.001 | 1.647 | 1.218 | 2.226 |
| Number of needle adjustment | 0.179 | 10.769 | 0.001 | 1.802 | 1.268 | 2.561 |
| Pneumothorax (present vs absent) | 0.812 | 7.346 | 0.007 | 9.038 | 1.840 | 44.41 |
| Total scan length(cm) | 0.023 | 18.023 | <0.001 | 1.104 | 1.054 | 1.155 |
| BMI (kg/m2) | 0.184 | 13.647 | <0.001 | 1.973 | 1.376 | 2.829 |
| Total scan length(cm) | 0.045 | 16.346 | <0.001 | 1.199 | 1.098 | 1.309 |
Single factor binary logistic regression analysis of the total scan length of the low-dose optimization group.
| Variable parameter | Standard error | Wald | P | Exp(B) | 95% CI of EXP(B) | |
|---|---|---|---|---|---|---|
| Lower | Upper | |||||
| Lesion diameter (cm) | 0.164 | 9.961 | 0.002 | 0.596 | 0.433 | 0.822 |
| Puncture depth (cm) | 0.150 | 9.260 | 0.002 | 1.578 | 1.176 | 2.116 |
| Distance across lung (cm) | 0.216 | 14.241 | <0.001 | 2.255 | 1.478 | 3.441 |
| Bleeding (present vs absent) | 0.698 | 7.977 | 0.005 | 7.181 | 1.828 | 28.202 |
| Pneumothorax (present vs absent) | 1.074 | 8.398 | 0.004 | 22.458 | 2.738 | 184.235 |
| Distance across lung (cm) | 0.228 | 7.282 | 0.007 | 1.852 | 1.184 | 2.899 |
| Bleeding (present vs absent) | 0.765 | 8.086 | 0.004 | 8.810 | 1.966 | 39.475 |
| Pneumothorax (present vs absent) | 1.116 | 9.155 | 0.002 | 29.250 | 3.284 | 260.513 |