Ann Barry Flood1, Victoria A Wood2, Harold M Swartz2. 1. EPR Center for the Study of Viable Systems at Dartmouth, Geisel School of Medicine at Dartmouth College, Hanover, NH, USA. Ann.B.Flood@Dartmouth.edu. 2. EPR Center for the Study of Viable Systems at Dartmouth, Geisel School of Medicine at Dartmouth College, Hanover, NH, USA.
Abstract
Clinical EPR spectroscopy is emerging as an important modality, with the potential to be used in standard clinical practice to determine the extent of hypoxia in tissues and whether hypoxic tissues respond to breathing enriched oxygen during therapy. Oximetry can provide important information useful for prognosis and to improve patient outcomes. EPR oximetry has many potential advantages over other ways to measure oxygen in tissues, including directly measuring oxygen in tissues and being particularly sensitive to low oxygen, repeatable, and non-invasive after an initial injection of the EPR-sensing material is placed in the tumor. The most immediately available oxygen sensor is India ink, where two classes of carbon (carbon black and charcoal) have been identified as having acceptable paramagnetic properties for oximetry. While India ink has a long history of safe use in tattoos, a systematic research search regarding its safety for marking tissues for medical uses and an examination of the evidence that differentiates between ink based on charcoal or carbon black has not been conducted. METHODS: Using systematic literature search techniques, we searched the PubMed and Food and Drug Administration databases, finding ~1000 publications reporting on adverse events associated with India/carbon based inks. The detailed review of outcomes was based on studies involving >16 patients, where the ink was identifiable as carbon black or charcoal. RESULTS: Fifty-six studies met these criteria. There were few reports of complications other than transient and usually mild discomfort and bleeding at injection, and there was no difference in charcoal vs. carbon black India ink. CONCLUSIONS: India ink was generally well tolerated by patients and physicians reported that it was easy to use in practice and used few resources. The risk is low enough to justify its use as an oxygen sensor in clinical practice.
Clinical EPR spectroscopy is emerging as an important modality, with the potential to be used in standard clinical practice to determine the extent of hypoxia in tissues and whether hypoxic tissues respond to breathing enriched oxygen during therapy. Oximetry can provide important information useful for prognosis and to improve patient outcomes. EPR oximetry has many potential advantages over other ways to measure oxygen in tissues, including directly measuring oxygen in tissues and being particularly sensitive to low oxygen, repeatable, and non-invasive after an initial injection of the EPR-sensing material is placed in the tumor. The most immediately available oxygen sensor is India ink, where two classes of carbon (carbon black and charcoal) have been identified as having acceptable paramagnetic properties for oximetry. While India ink has a long history of safe use in tattoos, a systematic research search regarding its safety for marking tissues for medical uses and an examination of the evidence that differentiates between ink based on charcoal or carbon black has not been conducted. METHODS: Using systematic literature search techniques, we searched the PubMed and Food and Drug Administration databases, finding ~1000 publications reporting on adverse events associated with India/carbon based inks. The detailed review of outcomes was based on studies involving >16 patients, where the ink was identifiable as carbon black or charcoal. RESULTS: Fifty-six studies met these criteria. There were few reports of complications other than transient and usually mild discomfort and bleeding at injection, and there was no difference in charcoal vs. carbon black India ink. CONCLUSIONS:India ink was generally well tolerated by patients and physicians reported that it was easy to use in practice and used few resources. The risk is low enough to justify its use as an oxygen sensor in clinical practice.
Entities:
Keywords:
Adverse Events; Carbon particles; EPR sensot; India ink; Structured literature review
Authors: Nadeem Khan; Huagang Hou; Patrick Hein; Richard J Comi; Jay C Buckey; Oleg Grinberg; Ildar Salikhov; Shi Y Lu; Hermine Wallach; Harold M Swartz Journal: Adv Exp Med Biol Date: 2005 Impact factor: 2.622
Authors: Harold M Swartz; Benjamin B Williams; Huagang Hou; Nadeem Khan; Lesley A Jarvis; Eunice Y Chen; Philip E Schaner; Arif Ali; Bernard Gallez; Periannan Kuppusamy; Ann B Flood Journal: Adv Exp Med Biol Date: 2016 Impact factor: 2.622
Authors: Huagang Hou; Jin H Baek; Hao Zhang; Francine Wood; Yamei Gao; Ann B Flood; Harold M Swartz; Paul W Buehler Journal: Blood Transfus Date: 2019-05-16 Impact factor: 3.443
Authors: Eunice Y Chen; Dan Tse; Huagang Hou; Wilson A Schreiber; Philip E Schaner; Maciej M Kmiec; Kendra A Hebert; Periannan Kuppusamy; Harold M Swartz; Benjamin B Williams Journal: Appl Magn Reson Date: 2021-07-09 Impact factor: 0.974
Authors: Philip E Schaner; Jason R Pettus; Ann Barry Flood; Benjamin B Williams; Lesley A Jarvis; Eunice Y Chen; David A Pastel; Rebecca A Zuurbier; Roberta M diFlorio-Alexander; Harold M Swartz; Periannan Kuppusamy Journal: Front Oncol Date: 2020-10-27 Impact factor: 6.244