Huagang Hou1, Jin H Baek2, Hao Zhang3, Francine Wood2, Yamei Gao4, Ann B Flood1, Harold M Swartz1, Paul W Buehler2. 1. Department of Radiology, Geisel School of Medicine at Dartmouth College, Hanover, NH, United States of America. 2. Laboratory of Biochemistry and Vascular Biology, Division of Blood Components and Devices, Center of Biologics Evaluation and Research (CBER), FDA, Silver Spring, MD, United States of America. 3. Department of Chemistry, Dartmouth College, Hanover, NH, United States of America. 4. Division of Viral Products, Center of Biologics Evaluation and Research (CBER), FDA, Silver Spring, MD, United States of America.
Abstract
BACKGROUND: The goal of red blood cell transfusion is to improve tissue oxygenation. Assessment of red blood cell quality and individualised therapeutic needs can be optimised using direct oxygen (O2) measurements to guide treatment. Electron paramagnetic resonance oximetry is capable of accurate, repeatable and minimally invasive measurements of tissue pO2. Here we present preclinical proof-of-concept of the utility of electron paramagnetic resonance oximetry in an experimental setting of acute blood loss, transfusion, and post-transfusion monitoring. MATERIALS AND METHODS: Donor rat blood was collected, leucocyte-reduced, and stored at 4 °C in AS-3 for 1, 7 and 14 days. Red blood cell morphology, O2 equilibrium, p50 and Hill numbers from O2 binding and dissociation curves were evaluated in vitro. Recipient rats were bled and maintained at a mean arterial pressure of 30-40 mmHg and hind limb muscle (biceps femoris) pO2 at 25-50% of baseline. Muscle pO2 was monitored continuously over the course of experiments to assess the effectiveness of red blood cell preparations at different stages of blood loss and restoration. RESULTS: Red blood cell morphology, O2 equilibrium and p50 values of intra-erythrocyte haemoglobin were significantly altered by refrigerated storage for both 7 and 14 days. Transfusion of red blood cells stored for 7 or 14 days demonstrated an equivalently impaired ability to restore hind limb muscle pO2, consistent with in vitro observations and transfusion with albumin. Red blood cells refrigerated for 1 day demonstrated normal morphology, in vitro oxygenation and in vivo restoration of tissue pO2. DISCUSSION: Electron paramagnetic resonance oximetry represents a useful approach to assessing the quality of red blood cells and subsequent transfusion effectiveness.
BACKGROUND: The goal of red blood cell transfusion is to improve tissue oxygenation. Assessment of red blood cell quality and individualised therapeutic needs can be optimised using direct oxygen (O2) measurements to guide treatment. Electron paramagnetic resonance oximetry is capable of accurate, repeatable and minimally invasive measurements of tissue pO2. Here we present preclinical proof-of-concept of the utility of electron paramagnetic resonance oximetry in an experimental setting of acute blood loss, transfusion, and post-transfusion monitoring. MATERIALS AND METHODS:Donorrat blood was collected, leucocyte-reduced, and stored at 4 °C in AS-3 for 1, 7 and 14 days. Red blood cell morphology, O2 equilibrium, p50 and Hill numbers from O2 binding and dissociation curves were evaluated in vitro. Recipient rats were bled and maintained at a mean arterial pressure of 30-40 mmHg and hind limb muscle (biceps femoris) pO2 at 25-50% of baseline. Muscle pO2 was monitored continuously over the course of experiments to assess the effectiveness of red blood cell preparations at different stages of blood loss and restoration. RESULTS: Red blood cell morphology, O2 equilibrium and p50 values of intra-erythrocyte haemoglobin were significantly altered by refrigerated storage for both 7 and 14 days. Transfusion of red blood cells stored for 7 or 14 days demonstrated an equivalently impaired ability to restore hind limb muscle pO2, consistent with in vitro observations and transfusion with albumin. Red blood cells refrigerated for 1 day demonstrated normal morphology, in vitro oxygenation and in vivo restoration of tissue pO2. DISCUSSION: Electron paramagnetic resonance oximetry represents a useful approach to assessing the quality of red blood cells and subsequent transfusion effectiveness.
Authors: Jacques Lacroix; Paul C Hébert; Dean A Fergusson; Alan Tinmouth; Deborah J Cook; John C Marshall; Lucy Clayton; Lauralyn McIntyre; Jeannie Callum; Alexis F Turgeon; Morris A Blajchman; Timothy S Walsh; Simon J Stanworth; Helen Campbell; Gilles Capellier; Pierre Tiberghien; Laurent Bardiaux; Leo van de Watering; Nardo J van der Meer; Elham Sabri; Dong Vo Journal: N Engl J Med Date: 2015-03-17 Impact factor: 91.245
Authors: Bjoern Jacobi; Georg Bongartz; Sasan Partovi; Anja-Carina Schulte; Markus Aschwanden; Alan B Lumsden; Mark G Davies; Matthias Loebe; Georg P Noon; Sasan Karimi; John K Lyo; Daniel Staub; Rolf W Huegli; Deniz Bilecen Journal: J Magn Reson Imaging Date: 2012-06 Impact factor: 4.813
Authors: Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy Journal: Acad Radiol Date: 2014-02 Impact factor: 3.173
Authors: Ramasamy P Pandian; Narasimham L Parinandi; Govindasamy Ilangovan; Jay L Zweier; Periannan Kuppusamy Journal: Free Radic Biol Med Date: 2003-11-01 Impact factor: 7.376
Authors: Aggrey Dhabangi; Brenda Ainomugisha; Christine Cserti-Gazdewich; Henry Ddungu; Dorothy Kyeyune; Ezra Musisi; Robert Opoka; Christopher P Stowell; Walter H Dzik Journal: JAMA Pediatr Date: 2016-10-01 Impact factor: 16.193
Authors: Margaret J Ochocinska; Steven L Spitalnik; Alfred Abuhamad; Elliott Bennett-Guerrero; Waldemar A Carlo; Murali Cherukuri; Allan Doctor; Walter Dzik; Conor L Evans; Erica Forzani; Periannan Kuppusamy; Natacha Le Moan; Lei Li; Naomi Luban; Narla Mohandas; Ravi M Patel; John Roback; Harold Swartz; Stephen Textor; Sergei Vinogradov; Lihong V Wang; Natalie Wisniewski; Simone Glynn Journal: Transfus Med Rev Date: 2020-12-06