Literature DB >> 28673491

Assessment of Volumetric Distortion Artifact in Filled Root Canals Using Different Cone-beam Computed Tomographic Devices.

Berkan Celikten1, Reinhilde Jacobs2, Karla deFaria Vasconcelos3, Yan Huang4, Laura Ferreira Pinheiro Nicolielo2, Kaan Orhan5.   

Abstract

INTRODUCTION: Artifacts in cone-beam computed tomographic (CBCT) imaging may compromise radiodiagnosis. Obturation materials for endodontic treatment may present with variable material density and thus also cause distinct artifact expression. The aim of this study was to assess the volume distortion artifact of root canal sealers using CBCT devices and micro-CT imaging as a reference.
METHODS: Thirty single-root mandibular central incisors were used for this study. Teeth were prepared with EndoSequence rotary nickel-titanium files (Brasseler USA, Savannah, GA) and divided into 3 groups. Canals were obturated with gutta-percha and AH Plus root canal sealer (Dentsply Maillefer, Ballaigues, Switzerland) using single-cone filling techniques. Each tooth was scanned with different CBCT devices (ie, Promax 3D Max [Planmeca Inc, Roselle, IL], NewTom VGi evo [NewTom, Verona, Italy], and 3D Accuitomo 170 [J Morita, Kyoto, Japan]) with the same voxel size (0.2 mm3) and compared with micro-CT imaging as a reference standard.
RESULTS: The results showed a significant difference in terms of volume distortion between micro-CT and CBCT images (P < .05). There were also significant differences among CBCT devices. Promax 3D Max measurements showed significantly larger root canal volumes than the other CBCT machines (P < .05). However, NewTom VGi evo and 3D Accuitomo 170 showed similar results without any significant difference (P > .05).
CONCLUSIONS: CBCT devices showed more volumetric distortion artifact than micro-CT imaging. The volume was variable for different CBCT devices while scanning at the same voxel size. However, to assess the effect of sealer materials on CBCT imaging, further studies should be conducted for different sealers.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Artifact; cone-beam computed tomographic machines; micro–computed tomographic imaging; root canal sealer

Mesh:

Substances:

Year:  2017        PMID: 28673491     DOI: 10.1016/j.joen.2017.03.035

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

Review 1.  Precision medicine using patient-specific modelling: state of the art and perspectives in dental practice.

Authors:  Pierre Lahoud; Reinhilde Jacobs; Philippe Boisse; Mostafa EzEldeen; Maxime Ducret; Raphael Richert
Journal:  Clin Oral Investig       Date:  2022-06-10       Impact factor: 3.606

2.  Is it possible to estimate volume of bone defects formed on dry sheep mandibles more practically by secondarily reconstructing section thickness of cone beam computed tomography images?

Authors:  Alaettin Koç; Sema Kaya
Journal:  Dentomaxillofac Radiol       Date:  2020-10-15       Impact factor: 2.419

3.  Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices.

Authors:  Deivi Cascante-Sequeira; Fernanda Coelho-Silva; Lucas P Lopes Rosado; Deborah Queiroz Freitas; Sergio Lins de-Azevedo-Vaz; Francisco Haiter-Neto
Journal:  Clin Oral Investig       Date:  2021-07-29       Impact factor: 3.606

4.  Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars.

Authors:  Clarissa Teles Rodrigues; Reinhilde Jacobs; Karla Faria Vasconcelos; Paul Lambrechts; Izabel Regina Fisher Rubira-Bullen; Hugo Gaêta-Araujo; Christiano Oliveira-Santos; Marco Antonio Hungaro Duarte
Journal:  Dentomaxillofac Radiol       Date:  2021-01-05       Impact factor: 3.525

5.  Quantitative Analysis of Cone-Beam Computed Tomography Artifacts Induced by Nonmetallic Root Canal Filling Materials Using Different Fields of View: In Vitro Study.

Authors:  Rahaf A AlMohareb; Reem M Barakat; Mohamed Mehanny
Journal:  Scanning       Date:  2022-02-22       Impact factor: 1.932

6.  CBCT-based assessment of root canal treatment using micro-CT reference images.

Authors:  Alessando Lamira; Jardel Francisco Mazzi-Chaves; Laura Ferreira Pinheiro Nicolielo; Graziela Bianchi Leoni; Alice Corrêa Silva-Sousa; Yara Terezinha Corrêa Silva-Sousa; Ruben Pauwels; Nico Buls; Reinhilde Jacobs; Manoel Damião Sousa-Neto
Journal:  Imaging Sci Dent       Date:  2022-05-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.