Ultrasonic motors (USMs) are common actuators that can be safely used in the magnetic resonance imaging (MRI) environment. However, lack of MRI compatibility results in issues such as image distortion. This fact led researchers to shift focus from USMs to pneumatic and hydraulic actuators in development of surgical robots. The aim is to quantify and compensate the geometric distortion of MR images as generated by the presence of USMs. An ultrasonic motor was positioned in three orientations with respect to the bore axis. The induced distortions were compared across four image sequences. To reduce the distortions, three artifact reduction methods were employed. Geometric distortion is the only artifact in image slices farther from the motor. The various motor orientations lead to different distortions, with the lowest distortion for the z orientation. The maximum measured distortion of ten pixels occurred. This maximal distortion is equal to a 1-cm displacement of the displayed points relative to their actual locations and it is beyond the acceptable level for medical display standards. Bandwidth reduction reduced the distortion, with a 50% reduction for a doubled bandwidth. In conclusion, USMs can be preferred alternative because accurate targeting of pathologies can occur in free distorted images.

Keywords:  Artifact reduction; Geometric distortion; MRI-compatibility; Robotic surgery; Ultrasonic motor

Mesh:

Year:  2017        PMID: 28670659     DOI: 10.1007/s11517-017-1665-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  On the accuracy of unwarping techniques for the correction of susceptibility-induced geometric distortion in magnetic resonance Echo-planar images.

Authors:  Ali Gholipour; Nasser Kehtarnavaz; Benoit Scherrer; Simon K Warfield
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Authors:  Ehsan Samei; Aldo Badano; Dev Chakraborty; Ken Compton; Craig Cornelius; Kevin Corrigan; Michael J Flynn; Bradley Hemminger; Nick Hangiandreou; Jeffrey Johnson; Donna M Moxley-Stevens; William Pavlicek; Hans Roehrig; Lois Rutz; Jeffrey Shepard; Robert A Uzenoff; Jihong Wang; Charles E Willis
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

Review 3.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

Authors:  Nikolaos V Tsekos; Azadeh Khanicheh; Eftychios Christoforou; Constantinos Mavroidis
Journal:  Annu Rev Biomed Eng       Date:  2007       Impact factor: 9.590

4.  Characterization, prediction, and correction of geometric distortion in 3 T MR images.

Authors:  Lesley N Baldwin; Keith Wachowicz; Steven D Thomas; Ryan Rivest; B Gino Fallone
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

Review 5.  Artifacts in 3-T MRI: physical background and reduction strategies.

Authors:  Olaf Dietrich; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur J Radiol       Date:  2007-12-26       Impact factor: 3.528

Review 6.  The case for MR-compatible robotics: a review of the state of the art.

Authors:  Haytham Elhawary; Zion Tsz Ho Tse; Abbi Hamed; Marc Rea; Brian L Davies; Michael U Lamperth
Journal:  Int J Med Robot       Date:  2008-06       Impact factor: 2.547

Review 7.  Metal-induced artifacts in MRI.

Authors:  Brian A Hargreaves; Pauline W Worters; Kim Butts Pauly; John M Pauly; Kevin M Koch; Garry E Gold
Journal:  AJR Am J Roentgenol       Date:  2011-09       Impact factor: 3.959

8.  Susceptibility artefacts in NMR imaging.

Authors:  K M Lüdeke; P Röschmann; R Tischler
Journal:  Magn Reson Imaging       Date:  1985       Impact factor: 2.546

9.  "MRI Stealth" robot for prostate interventions.

Authors:  Dan Stoianovici; Danny Song; Doru Petrisor; Daniel Ursu; Dumitru Mazilu; Michael Muntener; Michael Mutener; Michael Schar; Alexandru Patriciu
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

  9 in total
  4 in total

1.  A study on observed ultrasonic motor-induced magnetic resonance imaging (MRI) artifacts.

Authors:  Peyman Shokrollahi; James M Drake; Andrew A Goldenberg
Journal:  Biomed J       Date:  2019-05-06       Impact factor: 4.910

2.  MRI-guided robotic arm drives optogenetic fMRI with concurrent Ca2+ recording.

Authors:  Yi Chen; Patricia Pais-Roldan; Xuming Chen; Michael H Frosz; Xin Yu
Journal:  Nat Commun       Date:  2019-06-10       Impact factor: 17.694

Review 3.  Sweet dreams: How mini-invasive surgery tackles obstructive sleep apnea.

Authors:  Sophia Julia Häfner
Journal:  Biomed J       Date:  2019-05-20       Impact factor: 4.910

4.  NITINOL-based actuator for device control even in high-field MRI environment.

Authors:  Marco Kalmar; Axel Boese; Ivan Maldonado; Rainer Landes; Michael Friebe
Journal:  Med Devices (Auckl)       Date:  2019-08-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.