Literature DB >> 28667589

Design and evaluation of safety operation VR training system for robotic catheter surgery.

Yu Wang1, Shuxiang Guo2,3, Yaxin Li4, Takashi Tamiya5, Yu Song6.   

Abstract

A number of remote robotic catheter systems have been developed to protect physicians from X-ray exposure in endovascular surgery. However, the teleoperation prevents the physicians sensing the force directly which may easily result in healthy vessels injured. To realize the safe operation, a tissue protection-based VR training system has been developed in this paper to prevent collateral damage by collision. The integrated VR simulator cannot only remind the novice possible collisions by visual signs, but also cooperate with the newly designed tissue protection mechanism to remit collision trauma beforehand. Such mechanism exploits the diameter variable pulley in order to implement the safe interaction between catheter and vasculature. To testify the effectiveness of the tissue protection in training system, we invited four non-medical students to participate the successive 5 days training session. The evaluation results show that the average impingement distance (representing tissue damage) to vascular wall has been reduced to 0.6 mm, and the collision frequency is greatly decreased which implies the realization of relative safe catheterization.

Entities:  

Keywords:  Collision trauma; Minimally endovascular surgery; Robotic catheter operation; Tissue protection; Virtual reality-based training system

Mesh:

Year:  2017        PMID: 28667589     DOI: 10.1007/s11517-017-1666-2

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Vascular deformation for vascular interventional surgery simulation.

Authors:  Dapeng Zhang; Tianmiao Wang; Da Liu; Guo Lin
Journal:  Int J Med Robot       Date:  2010-06       Impact factor: 2.547

2.  Design and Evaluation of a Catheter Contact-Force Controller for Cardiac Ablation Therapy.

Authors:  Daniel Gelman; Allan C Skanes; Mohammad A Tavallaei; Maria Drangova
Journal:  IEEE Trans Biomed Eng       Date:  2016-02-04       Impact factor: 4.538

3.  Master-slave robotic platform and its feasibility study for micro-neurosurgery.

Authors:  Mamoru Mitsuishi; Akio Morita; Naohiko Sugita; Shigeo Sora; Ryo Mochizuki; Keiji Tanimoto; Young Min Baek; Hiroki Takahashi; Kanako Harada
Journal:  Int J Med Robot       Date:  2012-05-16       Impact factor: 2.547

4.  A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention.

Authors:  Yasuo Okumura; Susan B Johnson; T Jared Bunch; Benhur D Henz; Christine J O'Brien; Douglas L Packer
Journal:  J Cardiovasc Electrophysiol       Date:  2008-03-26

5.  A novel hybrid microrobot using rotational magnetic field for medical applications.

Authors:  Qiang Fu; Shuxiang Guo; Yasuhiro Yamauchi; Hideyuki Hirata; Hidenori Ishihara
Journal:  Biomed Microdevices       Date:  2015-04       Impact factor: 2.838

6.  First experience with a novel robotic remote catheter system: Amigo™ mapping trial.

Authors:  Ejaz M Khan; William Frumkin; G Andre Ng; Suresh Neelagaru; Freddy M Abi-Samra; Jay Lee; Michael Giudici; Douglas Gohn; Roger A Winkle; Jonathan Sussman; Bradley P Knight; Adam Berman; Hugh Calkins
Journal:  J Interv Card Electrophysiol       Date:  2013-05-01       Impact factor: 1.900

7.  A virtual-reality simulator and force sensation combined catheter operation training system and its preliminary evaluation.

Authors:  Yu Wang; Shuxiang Guo; Takashi Tamiya; Hideyuki Hirata; Hidenori Ishihara; Xuanchun Yin
Journal:  Int J Med Robot       Date:  2016-08-19       Impact factor: 2.547

8.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

9.  Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion.

Authors:  Vania Tacher; MingDe Lin; Pascal Desgranges; Jean-Francois Deux; Thijs Grünhagen; Jean-Pierre Becquemin; Alain Luciani; Alain Rahmouni; Hicham Kobeiter
Journal:  J Vasc Interv Radiol       Date:  2013-09-12       Impact factor: 3.464

10.  Virtual reality training in neurosurgery: Review of current status and future applications.

Authors:  Ali Alaraj; Michael G Lemole; Joshua H Finkle; Rachel Yudkowsky; Adam Wallace; Cristian Luciano; P Pat Banerjee; Silvio H Rizzi; Fady T Charbel
Journal:  Surg Neurol Int       Date:  2011-04-28
View more
  2 in total

Review 1.  Bioengineering, augmented reality, and robotic surgery in vascular surgery: A literature review.

Authors:  Sara Condino; Roberta Piazza; Marina Carbone; Jonathan Bath; Nicola Troisi; Mauro Ferrari; Raffaella Berchiolli
Journal:  Front Surg       Date:  2022-08-19

2.  A Magnetorheological Fluids-Based Robot-Assisted Catheter/Guidewire Surgery System for Endovascular Catheterization.

Authors:  Linshuai Zhang; Shuoxin Gu; Shuxiang Guo; Takashi Tamiya
Journal:  Micromachines (Basel)       Date:  2021-05-30       Impact factor: 2.891

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.