Literature DB >> 30460155

Depth-multiplexed optical coherence tomography dual-beam manually-actuated distortion-corrected imaging (DMDI) with a micromotor catheter.

Anthony M D Lee1, Calum MacAulay1, Pierre Lane1.   

Abstract

We present a new micromotor catheter implementation of dual-beam manually-actuated distortion-corrected imaging (DMDI). The new catheter called a depth-multiplexed dual-beam micromotor catheter, or mDBMC, maintains the primary advantage of unlimited field-of-view distortion-corrected imaging along the catheter axis. The mDBMC uses a polarization beam splitter and cube mirror to create two beams that scan circularly with approximately constant separation at the catheter surface. This arrangement also multiplexes both imaging channels into a single optical coherence tomography channel by offsetting them in depth, requiring half the data bandwidth compared to previous DMDI demonstrations that used two parallel image acquisition systems. Furthermore, the relatively simple scanning pattern of the two beams enables a straightforward automated distortion correction algorithm. We demonstrate the imaging capabilities of this catheter with a printed paper phantom and in a section of dragon fruit.

Entities:  

Year:  2018        PMID: 30460155      PMCID: PMC6238937          DOI: 10.1364/BOE.9.005678

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  15 in total

1.  Manual-scanning optical coherence tomography probe based on position tracking.

Authors:  Jian Ren; Jigang Wu; Emily J McDowell; Changhuei Yang
Journal:  Opt Lett       Date:  2009-11-01       Impact factor: 3.776

2.  Ultrahigh speed en face OCT capsule for endoscopic imaging.

Authors:  Kaicheng Liang; Giovanni Traverso; Hsiang-Chieh Lee; Osman Oguz Ahsen; Zhao Wang; Benjamin Potsaid; Michael Giacomelli; Vijaysekhar Jayaraman; Ross Barman; Alex Cable; Hiroshi Mashimo; Robert Langer; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2015-03-05       Impact factor: 3.732

3.  Dual-beam manually actuated distortion-corrected imaging (DMDI): two dimensional scanning with a single-axis galvanometer.

Authors:  Madeline Harlow; Calum MacAulay; Pierre Lane; Anthony M D Lee
Journal:  Opt Express       Date:  2018-07-09       Impact factor: 3.894

4.  Endoscopic high-resolution autofluorescence imaging and OCT of pulmonary vascular networks.

Authors:  Hamid Pahlevaninezhad; Anthony M D Lee; Geoffrey Hohert; Stephen Lam; Tawimas Shaipanich; Eve-Lea Beaudoin; Calum MacAulay; Caroline Boudoux; Pierre Lane
Journal:  Opt Lett       Date:  2016-07-15       Impact factor: 3.776

5.  Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo.

Authors:  Kaicheng Liang; Zhao Wang; Osman O Ahsen; Hsiang-Chieh Lee; Benjamin M Potsaid; Vijaysekhar Jayaraman; Alex Cable; Hiroshi Mashimo; Xingde Li; James G Fujimoto
Journal:  Optica       Date:  2018-01-20       Impact factor: 11.104

6.  Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivo.

Authors:  David C Adams; Lida P Hariri; Alyssa J Miller; Yan Wang; Josalyn L Cho; Martin Villiger; Jasmin A Holz; Margit V Szabari; Daniel L Hamilos; R Scott Harris; Jason W Griffith; Brett E Bouma; Andrew D Luster; Benjamin D Medoff; Melissa J Suter
Journal:  Sci Transl Med       Date:  2016-10-05       Impact factor: 17.956

7.  Dual-beam manually-actuated distortion-corrected imaging (DMDI) with micromotor catheters.

Authors:  Anthony M D Lee; Geoffrey Hohert; Patricia T Angkiriwang; Calum MacAulay; Pierre Lane
Journal:  Opt Express       Date:  2017-09-04       Impact factor: 3.894

8.  Three-dimensional endomicroscopy of the human colon using optical coherence tomography.

Authors:  Desmond C Adler; Chao Zhou; Tsung-Han Tsai; Joe Schmitt; Qin Huang; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Express       Date:  2009-01-19       Impact factor: 3.894

9.  Enabling freehand lateral scanning of optical coherence tomography needle probes with a magnetic tracking system.

Authors:  Boon Y Yeo; Robert A McLaughlin; Rodney W Kirk; David D Sampson
Journal:  Biomed Opt Express       Date:  2012-06-08       Impact factor: 3.732

10.  Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging.

Authors:  Paritosh Pande; Guillermo L Monroy; Ryan M Nolan; Ryan L Shelton; Stephen A Boppart
Journal:  J Sens       Date:  2016       Impact factor: 2.137

View more