Literature DB >> 28663881

Achromatic doublet intraocular lens for full aberration correction.

Enrique J Fernandez1, Pablo Artal1.   

Abstract

A doublet intraocular lens optimized for both chromatic and monochromatic aberration correction in pseudophakic eyes is presented. Ray-tracing techniques were applied to design the lens in white light within a chromatic eye model. Combinations of two materials, already commonly used in intraocular lenses, as acrylic and silicone, were used. Iterative optimization algorithms were employed to correct for longitudinal chromatic aberration, spherical aberration and off-axis aberrations within 10 degrees of visual field. The performance of this lens was compared with a standard single-material aspheric intraocular lens. Near full aberration correction was achieved with the doublet intraocular lens. The modulation transfer function and Strehl ratio were superior for the doublet lens. Through-focus calculations were also conducted showing better optical quality for the doublet. Real higher-order aberrations from normal eyes were incorporated in the model to evaluate the effect on the doublet intraocular lens performance. Results showed that the doublet lens preserved its benefits under realistic conditions. This doublet intraocular lens should provide patients with a better quality of vision after it is further developed in terms of manufacturing and surgical limitations.

Entities:  

Keywords:  (170.4460) Ophthalmic optics and devices; (170.4470) Ophthalmology; (330.7326) Visual optics, modeling; (330.7335) Visual optics, refractive surgery

Year:  2017        PMID: 28663881      PMCID: PMC5480488          DOI: 10.1364/BOE.8.002396

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  35 in total

1.  Theoretical performance of intraocular lenses correcting both spherical and chromatic aberration.

Authors:  Henk A Weeber; Patricia A Piers
Journal:  J Refract Surg       Date:  2011-11-10       Impact factor: 3.573

2.  Binocular accommodation reaction and response times for normal observers.

Authors:  G Heron; B Winn
Journal:  Ophthalmic Physiol Opt       Date:  1989-04       Impact factor: 3.117

3.  Adaptive optics simulation of intraocular lenses with modified spherical aberration.

Authors:  Patricia A Piers; Enrique J Fernandez; Silvestre Manzanera; Sverker Norrby; Pablo Artal
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-12       Impact factor: 4.799

4.  Chromatic aberration and polychromatic image quality with diffractive multifocal intraocular lenses.

Authors:  Sowmya Ravikumar; Arthur Bradley; Larry N Thibos
Journal:  J Cataract Refract Surg       Date:  2014-07       Impact factor: 3.351

5.  Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.

Authors:  Fidel Vega; Francisco Alba-Bueno; María S Millán; Consuelo Varón; Miguel A Gil; Jose A Buil
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-06       Impact factor: 4.799

6.  Development of the SRK/T intraocular lens implant power calculation formula.

Authors:  J A Retzlaff; D R Sanders; M C Kraff
Journal:  J Cataract Refract Surg       Date:  1990-05       Impact factor: 3.351

Review 7.  Developments in the correction of presbyopia II: surgical approaches.

Authors:  W Neil Charman
Journal:  Ophthalmic Physiol Opt       Date:  2014-04-10       Impact factor: 3.117

Review 8.  Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications.

Authors:  Emanuel Rosen; Jorge L Alió; H Burkhard Dick; Steven Dell; Stephen Slade
Journal:  J Cataract Refract Surg       Date:  2016-02       Impact factor: 3.351

9.  Real and pseudoaccommodation in accommodative lenses.

Authors:  Ioannis G Pallikaris; Georgios A Kontadakis; Dimitra M Portaliou
Journal:  J Ophthalmol       Date:  2011-09-18       Impact factor: 1.909

10.  Three-dimensional evaluation of accommodating intraocular lens shift and alignment in vivo.

Authors:  Susana Marcos; Sergio Ortiz; Pablo Pérez-Merino; Judith Birkenfeld; Sonia Durán; Ignacio Jiménez-Alfaro
Journal:  Ophthalmology       Date:  2013-08-12       Impact factor: 12.079

View more
  1 in total

1.  Keratoconic eyes with stable corneal tomography could benefit more from custom intraocular lens design than normal eyes.

Authors:  Simon Schröder; Timo Eppig; Weidi Liu; Jens Schrecker; Achim Langenbucher
Journal:  Sci Rep       Date:  2019-03-05       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.