Optical Measurement of Straylight in Eyes With Cataract.

Onurcan Sahin, Alexandros Pennos, Harilaos Ginis, Lucia Hervella, Eloy A Villegas, Belen Cañizares, Jose Maria Marin, Ioannis Pallikaris, Pablo Artal.   

Abstract

PURPOSE: To measure straylight in a cohort of patients with cataract using a novel optical instrument and to correlate optical straylight values with clinical grade of cataracts and psychophysical straylight values.
METHODS: Measurements were performed on 53 eyes of 44 patients with cataract admitted to the ophthalmology service of the university hospital in Murcia, Spain, and 9 young volunteers with no known ophthalmic pathology. Lens opacities were classified according to the Lens Opacities Classification System Ill (LOCS III) under slit-lamp examination. Intraocular straylight was additionally assessed psychophysically using the C-Quant straylight meter (Oculus Optikgeräte GmbH, Wetzlar, Germany).
RESULTS: Optical measurements of the logarithm of the straylight parameter ranged from 1.01 to 2.01 (mean: 1.43 ± 0.244) in patients with cataract and 0.80 to 1.08 (mean: 0.92 ± 0.104) in healthy young volunteers. Straylight differed by a statistically significant amount among different LOCS III groups (P < .05). Moreover, the optically measured straylight parameter was positively correlated to the psychophysically estimated value (r = 0.803, P < .05).
CONCLUSIONS: A new compact optical instrument suitable for clinical measurements of straylight in the human eye has been developed. Optically measured straylight values were highly correlated to those that were obtained psychophysically. Optical measurement of straylight can be used for the objective classification of cataract opacities based on their optical impact. [J Refract Surg. 2016;32(12):846-850.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27930795     DOI: 10.3928/1081597X-20160920-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Performance of a differential contrast sensitivity method to measure intraocular scattering.

Authors:  Alexandros Pennos; Harilaos Ginis; Augusto Arias; Dimitrios Christaras; Pablo Artal
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

2.  The Effect of Induced Intraocular Stray Light on Recognition Thresholds for Pseudo-High-Pass Filtered Letters.

Authors:  Nilpa Shah; Steven C Dakin; Pádraig J Mulholland; Kalina Racheva; Juliane Matlach; Roger S Anderson
Journal:  Transl Vis Sci Technol       Date:  2022-05-02       Impact factor: 3.048

3.  Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.

Authors:  Ireneusz Grulkowski; Silvestre Manzanera; Lukasz Cwiklinski; Juan Mompeán; Alberto de Castro; Jose Maria Marin; Pablo Artal
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.