Literature DB >> 28649165

Advanced 3D Mesh Manipulation in Stereolithographic Files and Post-Print Processing for the Manufacturing of Patient-Specific Vascular Flow Phantoms.

Ryan P O'Hara1,2, Arpita Chand1,3, Sowmya Vidiyala1,3, Stacie M Arechavala1,4, Dimitrios Mitsouras5, Stephen Rudin2,3, Ciprian N Ionita1,2.   

Abstract

Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 - 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations.

Entities:  

Keywords:  3D Printing; Aneurysms; CTA Segmentation; Patient-Specific; Vascular Phantoms

Year:  2016        PMID: 28649165      PMCID: PMC5479063          DOI: 10.1117/12.2217036

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  17 in total

1.  Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients.

Authors:  Rüdiger Lange; Sabine Bleiziffer; Nicolo Piazza; Domenico Mazzitelli; Andrea Hutter; Peter Tassani-Prell; Jean-Claude Laborde; Robert Bauernschmitt
Journal:  Eur J Cardiothorac Surg       Date:  2011-04-22       Impact factor: 4.191

2.  Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms.

Authors:  Boris Lubicz; Laurent Collignon; Gaï Raphaeli; Olivier De Witte
Journal:  World Neurosurg       Date:  2011 Jul-Aug       Impact factor: 2.104

3.  Comparison of modern stroke thrombectomy approaches using an in vitro cerebrovascular occlusion model.

Authors:  M Mokin; S V Setlur Nagesh; C N Ionita; E I Levy; A H Siddiqui
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

Review 4.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association.

Authors:  Alan S Go; Dariush Mozaffarian; Véronique L Roger; Emelia J Benjamin; Jarett D Berry; William B Borden; Dawn M Bravata; Shifan Dai; Earl S Ford; Caroline S Fox; Sheila Franco; Heather J Fullerton; Cathleen Gillespie; Susan M Hailpern; John A Heit; Virginia J Howard; Mark D Huffman; Brett M Kissela; Steven J Kittner; Daniel T Lackland; Judith H Lichtman; Lynda D Lisabeth; David Magid; Gregory M Marcus; Ariane Marelli; David B Matchar; Darren K McGuire; Emile R Mohler; Claudia S Moy; Michael E Mussolino; Graham Nichol; Nina P Paynter; Pamela J Schreiner; Paul D Sorlie; Joel Stein; Tanya N Turan; Salim S Virani; Nathan D Wong; Daniel Woo; Melanie B Turner
Journal:  Circulation       Date:  2012-12-12       Impact factor: 29.690

5.  Anesthesia and perioperative management of patients undergoing transcatheter aortic valve implantation: analysis of 90 consecutive patients with focus on perioperative complications.

Authors:  Pierre-Grégoire Guinot; Jean-Pol Depoix; Laure Etchegoyen; Abdel Benbara; Sophie Provenchère; Marie-Pierre Dilly; Ivan Philip; Daniel Enguerand; Hassan Ibrahim; Alec Vahanian; Dominique Himbert; Nawaar Al-Attar; Patrick Nataf; Jean-Marie Desmonts; Philippe Montravers; Dan Longrois
Journal:  J Cardiothorac Vasc Anesth       Date:  2010-02-25       Impact factor: 2.628

6.  Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison.

Authors:  Maxim Mokin; Ciprian N Ionita; Swetadri Vasan Setlur Nagesh; Stephen Rudin; Elad I Levy; Adnan H Siddiqui
Journal:  J Neurointerv Surg       Date:  2014-04-30       Impact factor: 5.836

7.  US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results.

Authors:  David Fiorella; Elad I Levy; Aquilla S Turk; Felipe C Albuquerque; David B Niemann; Beverly Aagaard-Kienitz; Ricardo A Hanel; Henry Woo; Peter A Rasmussen; L Nelson Hopkins; Thomas J Masaryk; Cameron G McDougall
Journal:  Stroke       Date:  2007-02-08       Impact factor: 7.914

8.  Management of neuroform stent dislodgement and misplacement.

Authors:  L Paul Broadbent; Christopher J Moran; DeWitte T Cross; Colin P Derdeyn
Journal:  AJNR Am J Neuroradiol       Date:  2003-10       Impact factor: 3.825

9.  Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.

Authors:  Ciprian N Ionita; Maxim Mokin; Nicole Varble; Daniel R Bednarek; Jianping Xiang; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13

10.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

View more
  3 in total

Review 1.  Measuring and Establishing the Accuracy and Reproducibility of 3D Printed Medical Models.

Authors:  Elizabeth George; Peter Liacouras; Frank J Rybicki; Dimitrios Mitsouras
Journal:  Radiographics       Date:  2017-08-11       Impact factor: 5.333

Review 2.  Artificial vascular models for endovascular training (3D printing).

Authors:  Inez Torres; Nelson De Luccia
Journal:  Innov Surg Sci       Date:  2018-08-11

3.  3D Printed Cardiovascular Patient Specific Phantoms Used for Clinical Validation of a CT-derived FFR Diagnostic Software.

Authors:  Kelsey N Sommer; Lauren Shepard; Nitant Vivek Karkhanis; Vijay Iyer; Erin Angel; Michael F Wilson; Frank J Rybicki; Dimitrios Mitsouras; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.