Literature DB >> 19351981

Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.

Kjell Erlandsson1, Krzysztof Kacperski, Dean van Gramberg, Brian F Hutton.   

Abstract

D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a beta-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s(-1) MBq(-1) per head ((99m)Tc, 10 cm) (CS: 72 s(-1) MBq(-1)), and the tomographic sensitivity in the heart region was in the range 647-1107 s(-1) MBq(-1) (CS: 141 s(-1) MBq(-1)). The count rate increased linearly with increasing activity up to 1.44 M s(-1). The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

Entities:  

Mesh:

Year:  2009        PMID: 19351981     DOI: 10.1088/0031-9155/54/9/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  52 in total

1.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  New SPECT technology: potential and challenges.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-10       Impact factor: 9.236

4.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

5.  Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging.

Authors:  Orazio Schillaci; Roberta Danieli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

Review 6.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

Review 7.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

8.  CZT cameras: A technological jump for myocardial perfusion SPECT.

Authors:  Laetitia Imbert; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2015-06-25       Impact factor: 5.952

9.  Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol.

Authors:  Laetitia Imbert; Véronique Roch; Charles Merlin; Wassila Djaballah; Florent Cachin; Mathieu Perrin; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

10.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.