Literature DB >> 28622324

Postoperative change in lateral rectus muscle insertion measured by anterior segment optical coherence tomography.

J-Y Lee1, K-A Park1, I J Lyu2, S Y Oh1.   

Abstract

AimsThe aims of this study were to investigate the longitudinal change in lateral rectus (LR) muscle insertion after recession surgery, and to evaluate a relationship between insertion distance and postoperative amount of deviation.MethodsWe recruited 31 patients who underwent primary LR recession surgery with normal anterior segment structures. An AS-OCT scan of the LR muscle was performed at every visit. Data on sex, age, degree of deviation (prism diopter), and spur-LR insertion distance using AS-OCT were collected at preoperatively and postoperative months 1, 3, and 6. Spur-LR insertion was defined as the shortest distance between the insertion of the LR muscle and the scleral spur was measured using the caliper function in the AS-OCT software.ResultsThe mean distance of spur-LR insertion measured with AS-OCT was 5.5±0.7 mm preoperatively, and 11.1±0.9 mm at 1 month, 11.5±0.8 mm at 3 months, and 11.0±0.7 mm at 6 months postoperatively. There were significant differences in spur-LR insertion between postoperative 1 and 3 months, and between 3 and 6 months (generalized estimating equation, all P<0.001). The overall spur-LR insertion measurement has a significantly negative correlation with postoperative amount of deviation (Pearson's correlation, P=0.035, r=-0.218).ConclusionsAS-OCT is a useful instrument for understanding postoperative changes in EOM after tissue swelling subsides.

Entities:  

Mesh:

Year:  2017        PMID: 28622324      PMCID: PMC5684462          DOI: 10.1038/eye.2017.89

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  11 in total

1.  Normative measurements of orbital structures using MRI.

Authors:  A Ozgen; U Aydingöz
Journal:  J Comput Assist Tomogr       Date:  2000 May-Jun       Impact factor: 1.826

2.  Measurement of the limbus-insertion distance in adult strabismus patients with anterior segment optical coherence tomography.

Authors:  Xiaoqiang Liu; Fang Wang; Ying Xiao; Xinhai Ye; Lijie Hou
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-28       Impact factor: 4.799

3.  Experimental creeping muscle.

Authors:  M L Mazow; V Leal
Journal:  J Pediatr Ophthalmol       Date:  1976-05

4.  A study of the anatomical variations in the attachment of the oblique muscles of the eyeball.

Authors:  W H FINK
Journal:  Trans Am Acad Ophthalmol Otolaryngol       Date:  1947 May-Jun

5.  Reproducibility of horizontal extraocular muscle insertion distance in anterior segment optical coherence tomography and the effect of head position.

Authors:  Kyung-Ah Park; Ju Yeon Lee; Sei Yeul Oh
Journal:  J AAPOS       Date:  2014-02       Impact factor: 1.220

6.  Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size.

Authors:  J L Demer; B M Kerman
Journal:  Am J Ophthalmol       Date:  1994-09-15       Impact factor: 5.258

7.  The accuracy of anterior segment optical coherence tomography (AS-OCT) in localizing extraocular rectus muscles insertions.

Authors:  Cheryl S Ngo; David Smith; Stephen P Kraft
Journal:  J AAPOS       Date:  2015-06       Impact factor: 1.220

8.  Evaluation of the ultrasound biomicroscope in strabismus surgery.

Authors:  Patrick Watts; David Smith; Leslie Mackeen; Stephen Kraft; J Raymond Buncic; Mohamed Abdolell
Journal:  J AAPOS       Date:  2002-06       Impact factor: 1.220

9.  Extraocular muscle surgery in a rabbit model: site of reattachment following hang-back and conventional recession.

Authors:  H Ohtsuki; K Oshima; S Hasebe; R Kobashi; M Okano; T Furuse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-11       Impact factor: 3.117

10.  The site of reattachment of the extraocular muscle following hang-back recession.

Authors:  M X Repka; P J Fishman; D L Guyton
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1990 Nov-Dec       Impact factor: 1.402

View more
  3 in total

1.  One-Year Outcome Predictors of Strabismus Surgery from Anterior Segment Optical Coherence Tomography with Multiple B-Scan Averaging.

Authors:  Manabu Miyata; Kenji Suda; Akihito Uji; Masayuki Hata; Akio Oishi; Eri Nakano; Akinari Yamamoto; Shinya Nakao; Hiroshi Ohtsuki; Akitaka Tsujikawa
Journal:  Sci Rep       Date:  2019-02-21       Impact factor: 4.379

2.  Pre-, Intra-, and Post-Operative Evaluation of Extraocular Muscle Insertions Using Optical Coherence Tomography: A Comparison of Four Devices.

Authors:  Matthew S Pihlblad; Andrew Troia; Sapna Tibrewal; Parth R Shah
Journal:  J Clin Med       Date:  2019-10-19       Impact factor: 4.241

3.  Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography.

Authors:  Kiyo Shibata; Atsushi Fujiwara; Ichiro Hamasaki; Takehiro Shimizu; Reika Kono; Keisuke Kanenaga; Masanori Nakazawa; Yuki Morizane
Journal:  PLoS One       Date:  2020-12-23       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.