Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size.

J L Demer1, B M Kerman.   

Abstract

Using both standardized echography and high-resolution, surface coil magnetic resonance imaging, we measured the transverse diameter of recti extraocular muscles to evaluate comparative accuracy. Maximum transverse diameter of each rectus muscle in primary gaze was measured in 39 orbits of 20 subjects by using standardized A-scan echography. In the same orbits, we obtained multiple coronal magnetic resonance imaging planes by using a surface coil to span the anteroposterior extent of each orbit. Digital image analysis with the National Institutes of Health Image program was used to measure transverse muscle diameter. Average size for each rectus muscle was similar for the echographic and magnetic resonance imaging techniques. However, linear regressions of individual ultrasound against magnetic resonance imaging measurements showed coefficients of determination (R2) moderate (0.29) for inferior recti muscles and low (< or = 0.11) for other recti muscles. For most recti muscles, significant variability in echographic estimates of muscle width results from factors other than true muscle size. Results indicate that ultrasound measurements of muscle size in individual patients should be interpreted cautiously.

Entities:  

Mesh:

Year:  1994        PMID: 8085593     DOI: 10.1016/s0002-9394(14)72960-5

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  8 in total

1.  Update on advanced imaging options for thyroid-associated orbitopathy.

Authors:  Michael P Rabinowitz; Jacqueline R Carrasco
Journal:  Saudi J Ophthalmol       Date:  2012-10

2.  Echographic study of extraocular muscle thickness in normal Indian population.

Authors:  Priyangshu Chandra; Aditya Sudhalkar; Subhadra Jalali; Veerendranath Pesala; Raja Narayanan; Chinmaya Sahu; Jay Chhablani
Journal:  Saudi J Ophthalmol       Date:  2014-06-06

3.  Postoperative change in lateral rectus muscle insertion measured by anterior segment optical coherence tomography.

Authors:  J-Y Lee; K-A Park; I J Lyu; S Y Oh
Journal:  Eye (Lond)       Date:  2017-06-16       Impact factor: 3.775

4.  High-resolution magnetic resonance imaging demonstrates abnormalities of motor nerves and extraocular muscles in patients with neuropathic strabismus.

Authors:  Joseph L Demer; Maria Carolina Ortube; Elizabeth C Engle; Neepa Thacker
Journal:  J AAPOS       Date:  2006-04       Impact factor: 1.220

Review 5.  Recent developments in Graves' ophthalmopathy imaging.

Authors:  G J Kahaly
Journal:  J Endocrinol Invest       Date:  2004-03       Impact factor: 4.256

6.  Inferior oblique muscle thickness in Asians.

Authors:  Yasuhiro Takahashi; Hirohiko Kakizaki; Takashi Nakano; Ken Asamoto; Masayoshi Iwaki
Journal:  Clin Ophthalmol       Date:  2008-06

7.  Horizontal Extraocular Muscle and Scleral Anatomy in Children: A Swept-Source Anterior Segment Optical Coherence Tomography Study.

Authors:  Jung Yeob Han; Dong Cheol Lee; Se Youp Lee
Journal:  Korean J Ophthalmol       Date:  2018-03-19

8.  Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details.

Authors:  Amar Pujari; Sujeeth Modaboyina; Deepsekhar Das; Asmita Mahajan; Rajeswari Thangavel; Swati Phuljhele; Rohit Saxena; Namrata Sharma; Pradeep Sharma
Journal:  Clin Ophthalmol       Date:  2021-08-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.