Literature DB >> 26797555

Intraoperative Noise Increases Perceived Task Load and Fatigue in Anesthesiology Residents: A Simulation-Based Study.

Richard R McNeer1, Christopher L Bennett, Roman Dudaryk.   

Abstract

BACKGROUND: Operating rooms are identified as being one of the noisiest of clinical environments, and intraoperative noise is associated with adverse effects on staff and patient safety. Simulation-based experiments would offer controllable and safe venues for investigating this noise problem. However, realistic simulation of the clinical auditory environment is rare in current simulators. Therefore, we retrofitted our operating room simulator to be able to produce immersive auditory simulations with the use of typical sound sources encountered during surgeries. Then, we tested the hypothesis that anesthesia residents would perceive greater task load and fatigue while being given simulated lunch breaks in noisy environments rather than in quiet ones. As a secondary objective, we proposed and tested the plausibility of a novel psychometric instrument for the assessment of stress.
METHODS: In this simulation-based, randomized, repeated-measures, crossover study, 2 validated psychometric survey instruments, the NASA Task Load Index (NASA-TLX), composed of 6 items, and the Swedish Occupational Fatigue Inventory (SOFI), composed of 5 items, were used to assess perceived task load and fatigue, respectively, in first-year anesthesia residents. Residents completed the psychometric instruments after being given lunch breaks in quiet and noisy intraoperative environments (soundscapes). The effects of soundscape grouping on the psychometric instruments and their comprising items were analyzed with a split-plot analysis. A model for a new psychometric instrument for measuring stress that combines the NASA-TLX and SOFI instruments was proposed, and a factor analysis was performed on the collected data to determine the model's plausibility.
RESULTS: Twenty residents participated in this study. Multivariate analysis of variance showed an effect of soundscape grouping on the combined NASA-TLX and SOFI instrument items (P = 0.003) and the comparisons of univariate item reached significance for the NASA Temporal Demand item (P = 0.0004) and the SOFI Lack of Energy item (P = 0.001). Factor analysis extracted 4 factors, which were assigned the following construct names for model development: Psychological Task Load, Psychological Fatigue, Acute Physical Load, and Performance-Chronic Physical Load. Six of the 7 fit tests used in the partial confirmatory factor analysis were positive when we fitted the data to the proposed model, suggesting that further validation is warranted.
CONCLUSIONS: This study provides evidence that noise during surgery can increase feelings of stress, as measured by perceived task load and fatigue levels, in anesthesiologists and adds to the growing literature pointing to an overall adverse impact of clinical noise on caregivers and patient safety. The psychometric model proposed in this study for assessing perceived stress is plausible based on factor analysis and will be useful for characterizing the impact of the clinical environment on subject stress levels in future investigations.

Entities:  

Mesh:

Year:  2016        PMID: 26797555     DOI: 10.1213/ANE.0000000000001067

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

1.  A targeted noise reduction observational study for reducing noise in a neonatal intensive unit.

Authors:  S Chawla; P Barach; M Dwaihy; D Kamat; S Shankaran; B Panaitescu; B Wang; G Natarajan
Journal:  J Perinatol       Date:  2017-06-15       Impact factor: 2.521

2.  Physical hazard safety awareness among healthcare workers in Tanta university hospitals, Egypt.

Authors:  Rania M El-Sallamy; Ibrahim Ali Kabbash; Sanaa Abd El-Fatah; Asmaa El-Feky
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-17       Impact factor: 4.223

3.  Anesthesia Simulation Boot Camp-a Decade of Experience Enhancing Self-efficacy in First-year Residents.

Authors:  Christina Miller; Eric Jackson; Benjamin Lee; Allan Gottschalk; Adam Schiavi
Journal:  J Educ Perioper Med       Date:  2020-10-01

4.  Factors Affecting Acoustics and Speech Intelligibility in the Operating Room: Size Matters.

Authors:  Richard R McNeer; Christopher L Bennett; Danielle Bodzin Horn; Roman Dudaryk
Journal:  Anesth Analg       Date:  2017-06       Impact factor: 5.108

5.  The impact of the patient's initial NACA score on subjective and physiological indicators of workload during pre-hospital emergency care.

Authors:  Frederick Schneider; Jan Martin; Gerhard Schneider; Christian M Schulz
Journal:  PLoS One       Date:  2018-08-09       Impact factor: 3.240

6.  Using clinical simulation to study how to improve quality and safety in healthcare.

Authors:  Guillaume Lamé; Mary Dixon-Woods
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2018-09-29

7.  Development and Validation of an Algorithm for the Identification of Audible Medical Alarms.

Authors:  Paul Potnuru; Richard H Epstein; Richard McNeer; Christopher Bennett
Journal:  Cureus       Date:  2020-11-18

8.  A Framework to Assess Alarm Fatigue Indicators in Critical Care Staff.

Authors:  David Claudio; Shuchisnigdha Deb; Elizabeth Diegel
Journal:  Crit Care Explor       Date:  2021-06-14

9.  Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator.

Authors:  Richard R McNeer; Roman Dudaryk; Nicholas B Nedeff; Christopher L Bennett
Journal:  Anesthesiol Res Pract       Date:  2016-05-11

10.  Validation of the Raw National Aeronautics and Space Administration Task Load Index (NASA-TLX) Questionnaire to Assess Perceived Workload in Patient Monitoring Tasks: Pooled Analysis Study Using Mixed Models.

Authors:  Sadiq Said; Malgorzata Gozdzik; Tadzio Raoul Roche; Julia Braun; Julian Rössler; Alexander Kaserer; Donat R Spahn; Christoph B Nöthiger; David Werner Tscholl
Journal:  J Med Internet Res       Date:  2020-09-07       Impact factor: 5.428

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.