Literature DB >> 28609701

The 3D Pelvic Inclination Correction System (PICS): A universally applicable coordinate system for isovolumetric imaging measurements, tested in women with pelvic organ prolapse (POP).

Caecilia S Reiner1, Tom Williamson2, Thomas Winklehner2, Sean Lisse3, Daniel Fink4, John O L DeLancey3, Cornelia Betschart5.   

Abstract

In pelvic organ prolapse (POP), the organs are pushed downward along the lines of gravity, so measurements along this longitudinal body axis are desirable. We propose a universally applicable 3D coordinate system that corrects for changes in pelvic inclination and that allows the localization of any point in the pelvis at rest or under dynamic conditions on magnetic resonance images (MRI) of pelvic floor disorders in a scanner- and software independent manner. The proposed 3D coordinate system called 3D Pelvic Inclination Correction System (PICS) is constructed utilizing four bony landmark points, with the origin set at the inferior pubic point, and three additional points at the sacrum (sacrococcygeal joint) and both ischial spines, which are clearly visible on MRI images. The feasibility and applicability of the moving frame was evaluated using MRI datasets from five women with pelvic organ prolapse, three undergoing static MRI and two undergoing dynamic MRI of the pelvic floor in a supine position. The construction of the coordinate system was performed utilizing the selected landmarks, with an initial implementation completed in MATLAB. In all cases the selected landmarks were clearly visible, with the construction of the 3D PICS and measurement of pelvic organ positions performed without difficulty. The resulting distance from the organ position to the horizontal PICS plane was compared to a traditional measure based on standard measurements in 2D slices. The two approaches demonstrated good agreement in each of the cases. The developed approach makes quantitative assessment of pelvic organ position in a physiologically relevant 3D coordinate system possible independent of pelvic movement relative to the scanner. It allows the accurate study of the physiologic range of organ location along the body axis ("up or down") as well as defects of the pelvic sidewall or birth-related pelvic floor injuries outside the midsagittal plane, not possible before in a 2D reference line system. Measures in 3D can be monitored over time and may reveal pathology before bothersome symptoms appear, as well as allowing comparison of outcomes between different patient pools after different surgical approaches.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D coordinate system; 3D pelvic inclination correction system (PICS); Imaging; MRI; Pelvic organ prolapse; Pelvis

Mesh:

Year:  2017        PMID: 28609701      PMCID: PMC5526449          DOI: 10.1016/j.compmedimag.2017.05.005

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  33 in total

1.  Dynamic half Fourier acquisition, single shot turbo spin-echo magnetic resonance imaging for evaluating the female pelvis.

Authors:  A E Gousse; Z L Barbaric; M H Safir; S Madjar; A K Marumoto; S Raz
Journal:  J Urol       Date:  2000-11       Impact factor: 7.450

2.  Assessment of pelvic organ descent by use of functional cine-MRI: which reference line should be used?

Authors:  Andreas Lienemann; Dorothée Sprenger; Udo Janssen; Eva Grosch; Christoph Pellengahr; Christoph Anthuber
Journal:  Neurourol Urodyn       Date:  2004       Impact factor: 2.696

3.  The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction.

Authors:  R C Bump; A Mattiasson; K Bø; L P Brubaker; J O DeLancey; P Klarskov; B L Shull; A R Smith
Journal:  Am J Obstet Gynecol       Date:  1996-07       Impact factor: 8.661

4.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

5.  MRI-based segmentation of pubic bone for evaluation of pelvic organ prolapse.

Authors:  Sinan Onal; Susana K Lai-Yuen; Paul Bao; Alfredo Weitzenfeld; Stuart Hart
Journal:  IEEE J Biomed Health Inform       Date:  2014-07       Impact factor: 5.772

6.  Anatomy of the pubovisceral muscle origin: Macroscopic and microscopic findings within the injury zone.

Authors:  Jinyong Kim; Cornelia Betschart; Rajeev Ramanah; James A Ashton-Miller; John O L DeLancey
Journal:  Neurourol Urodyn       Date:  2014-08-22       Impact factor: 2.696

Review 7.  Tumor dose-volume response in image-guided adaptive brachytherapy for cervical cancer: A meta-regression analysis.

Authors:  Renaud Mazeron; Pauline Castelnau-Marchand; Alexandre Escande; Eleonor Rivin Del Campo; Pierre Maroun; Dimitri Lefkopoulos; Cyrus Chargari; Christine Haie-Meder
Journal:  Brachytherapy       Date:  2016-06-29       Impact factor: 2.362

8.  Methodology and clinical experience with computed tomography and a computer-resident stereotactic atlas.

Authors:  B A Kall; P J Kelly; S Goerss; G Frieder
Journal:  Neurosurgery       Date:  1985-09       Impact factor: 4.654

9.  Three-dimensional display in the evaluation and performance of neurosurgery without a stereotactic frame: more than a pretty picture?

Authors:  B A Kall; S J Goerss; P J Kelly; S O Stiving
Journal:  Stereotact Funct Neurosurg       Date:  1994       Impact factor: 1.875

10.  Establishing a normative atlas of the human lung: computing the average transformation and atlas construction.

Authors:  Baojun Li; Gary E Christensen; Eric A Hoffman; Geoffrey McLennan; Joseph M Reinhardt
Journal:  Acad Radiol       Date:  2012-08-28       Impact factor: 3.173

View more
  7 in total

1.  Analysis of long-term structural failure after native tissue prolapse surgery: a 3D stress MRI-based study.

Authors:  Luyun Chen; Payton Schmidt; John O DeLancey; Carolyn W Swenson
Journal:  Int Urogynecol J       Date:  2021-10-09       Impact factor: 1.932

2.  The establishment of a 3D anatomical coordinate system for defining vaginal axis and spatial position.

Authors:  Deanna C E Sinex; Shaniel T Bowen; Ahmed Kashkoush; Arianna Rosemond; Danielle Carter; Prahlad G Menon; Pamela A Moalli; Steven D Abramowitch
Journal:  Comput Methods Programs Biomed       Date:  2021-05-16       Impact factor: 7.027

3.  The feasibility of uterine-vaginal axis MRI-based as evaluation of surgical efficacy in women with pelvic organ prolapse.

Authors:  Haifeng Wang; Jihong Shen; Song Li; Zhenhua Gao; Kunbin Ke; Peng Gu
Journal:  Ann Transl Med       Date:  2022-04

4.  Pelvic inclination correction system for magnetic resonance imaging analysis of pelvic organ prolapse in upright position.

Authors:  Lisan M Morsinkhof; Martine K Schulten; John O L DeLancey; Frank F J Simonis; Anique T M Grob
Journal:  Int Urogynecol J       Date:  2022-07-30       Impact factor: 1.932

5.  Magnetic resonance imaging evaluation of the effectiveness of FemiCushion in pelvic organ prolapse.

Authors:  Yukiko Nomura; Yoshiyuki Okada; Chie Nakagawa; Ippei Kurokawa; Miwa Shigeta; Hidefumi Fujisawa; Yasukuni Yoshimura
Journal:  J Obstet Gynaecol Res       Date:  2022-02-28       Impact factor: 1.697

6.  Position and orientation of vaginal pessaries in situ on magnetic resonance imaging.

Authors:  Christopher X Hong; Elana Meer; Max Cioban; David J Tischfield; Daisy B Hassani; Heidi S Harvie
Journal:  Int Urogynecol J       Date:  2021-06-16       Impact factor: 2.894

7.  Preoperative level II/III MRI measures predicting long-term prolapse recurrence after native tissue repair.

Authors:  Payton Schmidt; Luyun Chen; John O DeLancey; Carolyn W Swenson
Journal:  Int Urogynecol J       Date:  2021-05-27       Impact factor: 1.932

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.