Literature DB >> 28604189

Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study.

Waleed Brinjikji1,2, Gregory Michalak1, Ramanathan Kadirvel1, Daying Dai1, Michael Gilvarry3, Sharon Duffy3,4, David F Kallmes1,2, Cynthia McCollough1, Shuai Leng1.   

Abstract

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.

Entities:  

Keywords:  Clot; computed tomography; dual energy; mechanical thrombectomy

Mesh:

Substances:

Year:  2017        PMID: 28604189      PMCID: PMC5490862          DOI: 10.1177/1591019917694479

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  17 in total

Review 1.  Correlation of imaging and histopathology of thrombi in acute ischemic stroke with etiology and outcome: a systematic review.

Authors:  Waleed Brinjikji; Sharon Duffy; Anthony Burrows; Werner Hacke; David Liebeskind; Charles B L M Majoie; Diederik W J Dippel; Adnan H Siddiqui; Pooja Khatri; Blaise Baxter; Raul Nogeuira; Matt Gounis; Tudor Jovin; David F Kallmes
Journal:  J Neurointerv Surg       Date:  2016-05-10       Impact factor: 5.836

2.  Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke.

Authors:  Sharon Duffy; Michael Farrell; Kevin McArdle; John Thornton; David Vale; Eleanor Rainsford; Liam Morris; David S Liebeskind; Eugene MacCarthy; Michael Gilvarry
Journal:  J Neurointerv Surg       Date:  2016-04-28       Impact factor: 5.836

3.  The hyperdense vessel sign on CT predicts successful recanalization with the Merci device in acute ischemic stroke.

Authors:  Michael T Froehler; Satoshi Tateshima; Gary Duckwiler; Reza Jahan; Nestor Gonzalez; Fernando Vinuela; David Liebeskind; Jeffrey L Saver; J Pablo Villablanca
Journal:  J Neurointerv Surg       Date:  2012-05-22       Impact factor: 5.836

4.  Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs.

Authors:  J Y Chueh; A K Wakhloo; G H Hendricks; C F Silva; J P Weaver; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-19       Impact factor: 3.825

5.  Cardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis.

Authors:  Jin Hur; Young Jin Kim; Hye-Jeong Lee; Ji Eun Nam; Yoo Jin Hong; Hee Yeong Kim; Ji Won Lee; Byoung Wook Choi
Journal:  Radiology       Date:  2012-04-10       Impact factor: 11.105

6.  The Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease.

Authors:  Raul G Nogueira; Elad I Levy; Matthew Gounis; Adnan H Siddiqui
Journal:  J Neurointerv Surg       Date:  2011-08-20       Impact factor: 5.836

7.  CT and MRI early vessel signs reflect clot composition in acute stroke.

Authors:  David S Liebeskind; Nerses Sanossian; William H Yong; Sidney Starkman; Michael P Tsang; Antonio L Moya; David D Zheng; Anna M Abolian; Doojin Kim; Latisha K Ali; Samir H Shah; Amytis Towfighi; Bruce Ovbiagele; Chelsea S Kidwell; Satoshi Tateshima; Reza Jahan; Gary R Duckwiler; Fernando Viñuela; Noriko Salamon; J Pablo Villablanca; Harry V Vinters; Victor J Marder; Jeffrey L Saver
Journal:  Stroke       Date:  2011-03-10       Impact factor: 7.914

8.  Histologic Analysis of Retrieved Clots in Acute Ischemic Stroke: Correlation with Stroke Etiology and Gradient-Echo MRI.

Authors:  S K Kim; W Yoon; T S Kim; H S Kim; T W Heo; M S Park
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-09       Impact factor: 3.825

9.  Dual-energy cardiac computed tomography for differentiating cardiac myxoma from thrombus.

Authors:  Yoo Jin Hong; Jin Hur; Young Jin Kim; Hye-Jeong Lee; Sae Rom Hong; Young Joo Suh; Hee Yeong Kim; Ji Won Lee; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-11       Impact factor: 2.357

10.  Quantitative assessment of device-clot interaction for stent retriever thrombectomy.

Authors:  Kajo van der Marel; Ju-Yu Chueh; Olivia W Brooks; Robert M King; Miklos G Marosfoi; Erin T Langan; Sarena L Carniato; Matthew J Gounis; Raul G Nogueira; Ajit S Puri
Journal:  J Neurointerv Surg       Date:  2016-02-01       Impact factor: 5.836

View more
  6 in total

Review 1.  Clot Pathophysiology: Why Is It Clinically Important?

Authors:  Patrick A Brouwer; Waleed Brinjikji; Simon F De Meyer
Journal:  Neuroimaging Clin N Am       Date:  2018-09-15       Impact factor: 2.264

Review 2.  Studying Stroke Thrombus Composition After Thrombectomy: What Can We Learn?

Authors:  Senna Staessens; Olivier François; Waleed Brinjikji; Karen M Doyle; Peter Vanacker; Tommy Andersson; Simon F De Meyer
Journal:  Stroke       Date:  2021-09-14       Impact factor: 7.914

3.  In-Vitro Visualization of Thrombus Growth in Artificial Lungs Using Real-Time X-Ray Imaging: A Feasibility Study.

Authors:  Andreas Kaesler; Freya Lilli Rudawski; Mark Oliver Zander; Felix Hesselmann; Isaac Pinar; Thomas Schmitz-Rode; Jutta Arens; Ulrich Steinseifer; Johanna Charlotte Clauser
Journal:  Cardiovasc Eng Technol       Date:  2021-09-16       Impact factor: 2.305

Review 4.  Dual-energy computed tomography in acute ischemic stroke: state-of-the-art.

Authors:  Stephanie Mangesius; Tanja Janjic; Ruth Steiger; Lukas Haider; Rafael Rehwald; Michael Knoflach; Gerlig Widmann; Elke Gizewski; Astrid Grams
Journal:  Eur Radiol       Date:  2020-12-14       Impact factor: 5.315

5.  Characterization of thrombus composition with multimodality CT-based imaging: an in-vitro study.

Authors:  Yong-Hong Ding; Mehdi Abbasi; Gregory Michalak; Shuai Leng; Daying Dai; Seán Fitzgerald; Ram Kadirvel; David F Kallmes; Waleed Brinjikji
Journal:  J Neurointerv Surg       Date:  2020-10-28       Impact factor: 8.572

6.  Study of correlations between CT properties of retrieved cerebral thrombi with treatment outcome of stroke patients.

Authors:  Rebeka Viltuznik; Jernej Vidmar; Andrej Fabjan; Miran Jeromel; Zoran V Milosevic; Igor J Kocijancic; Igor Sersa
Journal:  Radiol Oncol       Date:  2021-09-27       Impact factor: 2.991

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.